INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting 

installation. Read and follow the instructions provided 

with any tools listed here.

Tools Needed

 

Level

 

Drill with 1

1

/

4

" (3.2 cm), 

1

/

8

" (3.2 mm), 

and 

5

/

16

" (7.9  mm) drill bits

 

Pencil

 

Wire stripper or utility knife

 

Tape measure or ruler

 

Pliers

 

Caulking gun and weatherproof caulking compound

 

Vent clamps

 

Jigsaw or keyhole saw

 

Flat-blade screwdriver

 

Metal snips

 

Phillips screwdriver

 

T20

®

 Torx

®†

 adapter

Parts Needed

 

Home power supply cable

 

1

/

2

" (12.7 mm) UL listed or CSA approved strain relief

 

3 UL listed wire connectors

For Vented Installations, You Will Also Need:

 

1 wall or roof cap

 

Metal vent system

For Non-Vented (Recirculating) Installations, 

You Will Also Need:

 

Recirculation Kit for non-vented (recirculating) installations 

only. See the “Assistance or Service” section to order.

 

6" (15.2 cm) diameter round metal vent duct - 

length required is determined by ceiling height.

Parts Supplied

Remove parts from packages. Check that all parts are included.

 

Hood canopy assembly with blower, LED lights and 

canopy glass already installed

 

Vent transition with back draft dampers installed

 

Vent cover support bracket

 

Metal grease filter

 

Mounting template

 

2-piece vent cover

 

2 - 3.5 x 9.5 mm mounting screws (Phillips)

 

4 - 4 x 8 mm screws (T20

®†

 drive)

 

6 - 5 x 45 mm mounting screws (#2 Phillips)

 

4 - 8 x 40 mm wall anchors

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 

installer’s responsibility to comply with installation clearances 

specified on the model/serial/rating plate. The model/serial/

rating plate is located behind the left filter on the rear wall 

of the vent hood.
Canopy hood location should be away from strong draft areas, 

such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. 

Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with 

a maximum total rating of

 

65,000

 BTUs or less.

Grounded electrical outlet is required. See the “Electrical 

Requirements” section.
The canopy hood is factory set for venting through the roof 

or wall. For non-vented (recirculating) installation, see “For 

non-vented (recirculating) installation only” in the “Connect 

Vent System” section. Recirculation Kit is available from your 

dealer or an authorized parts distributor. See the “Assistance or 

Service” section to order.
All openings in ceiling and wall where canopy hood will be 

installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 

Manufactured Home Construction Safety Standards, Title 

24 CFR, Part 328 (formerly the Federal Standard for Mobile 

Home Construction and Safety, Title 24, HUD, Part 280) 

or, when such standard is not applicable, the standard for 

Manufactured Home Installation 1982 (Manufactured Home 

Sites, Communities and Setups) ANSI A225.1/NFPA 501A, 

or latest edition, or with local codes.

Product Dimensions

30"(76.2 cm) or
36" (91.4cm)

17

11

/

16

"(45 cm) 

13

3

/

16

"(33.5 cm)

10

13

/

16

"(27.5 cm) 

®

TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

Содержание WVW51UC0LS

Страница 1: ... DE CUISINIÈRE À MONTAGE MURAL DE 30 ET 36 76 2 ET 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 LIB0174087 W11549253A Applicable models Applicable modèles WVW51UC0LS WVW51UC6LS IMPORTANT READ AND SAVE THESE INS...

Страница 2: ...s product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Cover...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Страница 4: ...hnician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown mus...

Страница 5: ...ey extension replaces the upper chimney shipped with the range hood See the Assistance or Service section to order Venting Requirements vented models only Vent system must terminate to the outdoors except for non vented recirculating installations Do not terminate the vent system in an attic or other enclosed area Do not use 4 10 2 cm laundry type wall cap Use metal vent only Rigid metal vent is r...

Страница 6: ...irements Observe all governing codes and ordinances Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electr...

Страница 7: ...LATION ALTURA DE INSTALACIÓN VERTICAL CENTERLINE AXE CENTRAL VERTICAL LÍNEA CENTRAL VERTICAL DM09DC NOTE TEMPLATE MAY NOT BE TO SCALE MEASURE ALL DIMENSIONS REMARQUE LE MODÈLE NE POURRAIT PAS ÊTRE EN ÉCHELLE MESUREZ TOUTES LES DIMENSIONS NOTA LA PLANTILLA PUEDE NO ESTAR A ESCALA REAL EFECTUE TODAS LAS MEDICIONES 10 254 mm 11 280 mm A B C 4 Mark centers of the fastener locations through the templat...

Страница 8: ...nge hood and tighten upper mounting screws 4 Install 2 5 x 45 mm lower mounting screws and tighten Use the optional wall anchors if needed For non vented recirculating installation only 1 Assemble the air deflector with the duct cover bracket using 4 4 x 8 mm screws 2 A B C A Assembly screws B Air deflector C Duct cover bracket Measure from the bottom of the air deflector to the bottom of the hood...

Страница 9: ...ower InstallVent Covers NOTE Remove protective film from the vent covers 1 When using both upper and lower vent covers push lower cover down onto hood and then lift upper cover to ceiling and install with 2 4 x 8 mm screws NOTE For vented installations the upper vent cover may be reversed to hide slots B A C A Bracket B 4 x 8 mm screws C Vent cover A B C D E F G A Home power supply cable B UL list...

Страница 10: ... hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the front side of the canopy A B C D F E G A Duct cover holes B Duct cover C Control panel D Glass canopy E Grease filter F LED lights G Grease filter release handle Range Hood Controls A Light button B Turn the blower on and off ...

Страница 11: ...ase handles are toward the front Insert aluminum filter into upper track 4 Push in spring release handle 5 Push up on metal filter and release handle to latch into place Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up to 6 months with normal use Replace with Charcoal Filter Kit See the Assistance or Service section to order To replace charcoal fi...

Страница 12: ... BU BK 12 5uF WH BK BK YL GN BK BU WH BR YL BR WH WH YL WH PUSH BUTTON SWITCH OPERATION FUNCTION OFF LAMPS LOW SPEED MED SPEED HIGH SPEED POSITION NO CONNECTION BROWN YELLOW L 1 BROWN WHITE L 2 BROWN BLUE L 3 BROWN BLACK L 4 MOTOR SPECIFICATIONS POWER SUPPLY FREQUENCY POWER ABSORTION 120 VAC 60 Hz 240 W MOTOR RESISTANCE Ω S40 YL WH YL GN BLUE BLACK BLUE GREY BLUE RED BLUE WHITE 17 7 27 1 34 6 41 2...

Страница 13: ...Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www whirlpool ca Our Consultants Provide Assistance With Scheduling ...

Страница 14: ...areil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifien...

Страница 15: ...lafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINIÈRE Ne jamais laisser un élément de surface fonctionner à puissance de chauffage maximale sans surveillance Un renversement débordement de matière graisseuse pourrait provoquer une infl...

Страница 16: ...tallation de la hotte à un technicien qualifié C est à l installateur qu incombe la responsabilité de respecter les distances de séparation spécifiées sur la plaque signalétique de l appareil La plaque signalétique de l appareil est située derrière le filtre de gauche sur la paroi arrière de la hotte On doit toujours installer la hotte à distance des sources de courant d air fenêtres portes et bou...

Страница 17: ...fonds de hauteur supérieure un ensemble d extension de cacheconduit peut être acheté auprès de votre revendeur ou d un distributeur de pièces autorisé L extension de cache conduit remplace la section supérieure de cache conduit fournie avec la hotte Voir la section Assistance ou service pour commander Exigences concernant l évacuation Le circuit d évacuation doit décharger l air à l extérieur exce...

Страница 18: ...ences de l air ce qui réduit considérablement la performance La sortie à l extérieur du circuit d évacuation peut se faire à travers le toit ou à travers un mur Pour la sortie à travers un mur on doit employer un raccord coudé 90 Décharge par l arrière Le raccord coudé à 90 peut être installé immédiatement au dessus de la hotte Installation sans décharge à l extérieur recyclage S il n est pas poss...

Страница 19: ...e Placer le matériau de protection sur cette surface 4 À l aide de deux personnes ou plus soulever la hotte et la poser sur la surface couverte 5 Ôter la base en bois de la hotte de cuisine et jeter de façon convenable 6 Retirer le filtre à graisse en métal et le matériau d expédition en mousse se trouvant sous le ventilateur à l intérieur de la hotte de cuisine Installation des vis de montage de ...

Страница 20: ...tricité des normes CSA et des codes et règlements locaux Il faut que la longueur du conduit de 1 2 et des conducteurs soit suffisante depuis le tableau de distribution avec fusibles ou disjoncteurs pour réaliser le raccordement dans le boîtier de connexion de la hotte REMARQUE Ne pas mettre le système sous tension avant d avoir complètement terminé l installation 4 Utiliser un calfeutrant pour ass...

Страница 21: ...on et installer un serre câble de 12 7 mm homologation UL ou CSA A C B A Boîtier de connexion B Opercule arrachable C Couvercle du boîtier de connexion 4 Acheminer le cordon d alimentation du domicile à travers le serre câble dans le boîtier de connexion A B C A Vis d assemblage B Déflecteur d air C Bride de cache conduit X A C D B E A Déflecteur d air B Bride pour conduit C X longueur à laquelle ...

Страница 22: ...tion inférieure vers le bas sur la hotte et soulever la section supérieure vers le plafond puis installer l ensemble avec 2 vis de 4 x 8 mm B A C A Bride B Vis de 4 x 8 mm C Cache conduit 2 Fixer le bas du conduit avec 2 vis de 4 x 8 mm Achever l installation 1 Pour les installations sans décharge à l extérieur recyclage uniquement installer les filtres à charbon sur le filtre à graisse métallique...

Страница 23: ...tre à graisse F Lampes DEL G Poignée à ressort du filtre à graisse Commandes de la hotte de cuisinière A Bouton lumineux B Bouton marche arrêt C Bouton de vitesse moyenne du ventilateur D Bouton de vitesse maximale du ventilateur A B C D Utilisation de l éclairage Le bouton d éclairage marche arrêt contrôle les deux lampes Appuyer une fois pour marche et une deuxième fois pour arrêt Utilisation du...

Страница 24: ...ue dans la rainure supérieure 4 Tirer sur la poignée à ressort 5 Pousser le filtre métallique vers le haut et relâcher la poignée pour l emboîter Filtres d installation sans décharge à l extérieur recyclage Le filtre à charbon n est pas lavable Celui ci devrait durer pendant six mois maximum dans des conditions d utilisation normales Remplacer par l ensemble de filtre à charbon Voir la section Ass...

Страница 25: ... N N JA VE N BU BL MAR JA MAR BL BL JA BL LAMPES VITESSE BASSE VITESSE MOYENNE L 1 L 2 L 3 L 4 MARRON JAUNE MARRON BLANC MARRON BLEU MARRON NOIR ARRÊT PAS DE CONNEXION FONCTIONNEMENT DU COMMUTATEUR DU BOUTON POUSSOIR FONCTION POSITION 120 VCA 60 Hz 240 W CARACTERISTIQUES DU MOTEUR RÉSISTANCE DU MOTEUR Ω ALIMENTATION ÉLECTRIQUE FREQUENCE ABSORPTION DE COURANT VITESSE ÉLEVÉE S40 JA BL JA VE BLEU NOI...

Страница 26: ...duits et fournir un service après garantie partout au Canada Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Références aux marchands locaux Consignes d utilisation et d entretien Vente d accessoires et de pièces de rechange Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez soumettre par écrit toute question ou préoccupation à Whirlpoo...

Страница 27: ...27 Remarques ...

Страница 28: ... 2021 Whirlpool Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés W11549253A 05 21 ...

Отзывы: