Safe mode routine
During Constant fault condition, the Electronic Control will assume a safety routine, as in normal
cycle, trying to keep food conservation, however will work as follows:
• Compressor and Fan Motors will be on for 25 minutes and then will turn off for 20 minutes.
• Interval set between defrosts will be fixed in every 5 hours of the Compressor activity
• Every defrost time is fixed for 20 minutes. No dependency on defrost sensor for Cut Off temp of
15°C
Note: -
•
There is no Service routine provided in this model.
•
To check whether Heater is working fine or not, service person can use the Power up initialization
function of the model, where Product need to be switched Off & need to be ensured that the temp at
the FC sensor is >0°c, then after making the product ON product goes into the Power up initialization
mode where after product switch ON, heater gets activated for the first 5 seconds & then it goes to the
compressor mode after 3 minutes of heater getting off. Service person can make the use of this 5
seconds where by putting the Tong tester one can easily identify the healthy/faulty condition of the
heater through the driving current displayed on the tong tester it self at the Electronic core board box
location without opening the FC Plenum.
•
In case of any Aluminum foil wrapping found over the Wiring harness either in FC compartment, RC
Compartment or in the Compressor deck area, the same Al foil should be carefully replaces in same
fashion after servicing
•
In case of any detailed technical information please check with the Dlx technical specification.
Normal
Compressor
/Product
running
Mode
Sensor
Failed??
(Open/Shor
t Mode)
{RC, FC
sensor or
POT
Start Safe mode
routine
after 2 min of
error
Event in sensor
Yes
No
Whether
sensor/POT
is
repaired/cor
rected??
No
Yes
Содержание WRIBP41MC
Страница 4: ...4 ...
Страница 5: ...5 ...
Страница 9: ...9 Wiring Diagram Top Mount No Frost Dlx Refrigerant Charging quantity ...
Страница 10: ...10 ...
Страница 17: ...17 EXPLODED VIEWS ...
Страница 18: ...18 ...
Страница 19: ...19 ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 22: ...22 ...
Страница 23: ...23 1 ...
Страница 24: ...24 ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 28: ...28 Part No A2241780000 INTEGRATED DEFROST HEATER KENMORE ONYX PART LIST FOR ONYX AUSTRALIA ...