Electrical Requirements
Observe all governing codes and ordinances.
Required:
■
A 120 volt, 60 Hz, AC only, 15- or 20-amp electrical supply with a
fuse or circuit breaker.
Recommended:
■
A time-delay fuse or time-delay circuit breaker.
■
A separate circuit serving only this microwave oven.
Settings
Clock
The Clock is a 12-hour (12:00-11:59) or 24-hour (0:00-23:59) clock.
Touch OPTIONS/CLOCK to reach Clock submenu, and follow the
prompts to set the Clock. Clock format (12 hours with AM and PM,
12 hours without AM and PM or 24 hours) may also be set in the Clock
submenu.
Timer
With the microwave oven in standby mode, touch the Timer control,
enter time, then touch the Timer control or the Start control. Cook
functions may be entered while the Timer is counting down. To cancel
timer, touch Timer control while the Timer countdown is active in the
display.
Control Lock
Activate to avoid unintended start. Touch and hold the Cancel control
for about 3 seconds until 2 tones sound and padlock icon appears in
the display. Repeat to unlock control.
Options/Clock
Ten options/settings may be adjusted: 1-Clock & Energy Save;
2-Scrolling Speed; 3-Sound; 4-Language; 5-Auto Vent Fan; 6-Filter
Reset; 7-Fan Timer; 8-Light Timer; 9-Demo Mode; 10-Factory Reset.
Vent Fan
Various speeds, ranging from high to low, and off. Comes on
automatically as cooling fan during any cook function.
Vent Timer: Set vent fan to run for exactly 30 minutes, or to run for only
30 minutes more (off after 30 minutes). The vent fan may be turned off
at any time using the Vent Fan control. Touch OPTIONS/CLOCK to
reach the Fan Timer submenu, and select the setting.
Auto Vent Fan (on some models): To keep the microwave oven from
overheating, the auto vent fan will automatically turn on at high speed if
the temperature from the range or cooktop below the microwave oven
gets too hot. When this occurs, the vent fan cannot be turned off.
“AUTO FAN ON for heat circulation” appears in the display.
Dynamic Fan Sensing (on some models): To keep the microwave
oven from overheating, the auto vent fan will automatically turn on at
various speeds, depending on the temperature from the range or
cooktop below the microwave oven. When this occurs, the vent fan
cannot be turned off. “AUTO FAN Sensor Technology for heat
circulation” appears in the display. As the temperature cools, the fan will
automatically decrease its speed, then turn off.
Light Timer
Set the cooktop light to turn on and off at certain times. Touch
OPTIONS/CLOCK to reach the Light Timer submenu, and follow the
prompts to set the light on time and light off time in hours and minutes,
or to cancel Light Timer.
NOTE: Light Timer uses 12-hour clock only.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING:
Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
This device complies with Part 18 of the FCC Rules.