Step E - Install RO Faucet
13
You will need to select the location of the Reverse
Osmosis Faucet. You have three options to choose
from:
•Usetheexistingsinktopholeforthesprayhose
orsoapdispenser
(Must be 1-3/8” in diameter)
•Drillanewholeinthesink
•Drillanewholeinthecountertopnexttothe
sink
1
. Determine where you are going to install your
Reverse Osmosis Faucet.
2
. Check to ensure the Reverse Osmosis faucet will
mount flat against the mounting surface.
3
. Visually review the routing of the tubes from the
Reverse Osmosis filter assembly to the faucet.
Check to ensure there is adequate tube routing
space between the faucet and filter assembly.
4
. If drilling is needed, drill a 1-3/8" diameter hole in
the mounting surface.
IMPORTANT:Drillingholesintocountertopsand
sinksshouldonlybeperformedbyaninstaller
whoisqualifiedfordrillingsuchmaterials.
Drillingofsurfacesmadeofstoneorsolidsur-
facematerialssuchasgranite,marble,Corian™
orotherplasticresinproductsorsinksmadeof
porcelainorstainlesssteelmaycauseperma-
nent,irreparabledamagetothesinkorcounter-
topsurface.
FIG.14
SELECTLOCATIONOFREVERSEOSMOSIS
FAUCETMOUNTINGHOLE
Questions?CallTollFree1-866-986-3223
Monday- Friday, 8 AM - 7 PM EST
orvisitwww.whirlpoolwatertreatment.com
When you call, please be prepared to provide the model, date code and serial number,
found on the rating decal, located inside the cover.