background image

2

INSTALLATION INSTRUCTIONS

Tools and Parts

Check that you have everything necessary for correct installation. 
Proper installation is your responsibility.

Parts supplied:

Remove parts package from dryer drum. Check that all parts were 
included.

4 leveling legs

Parts needed:

Check local codes and consult gas supplier. Check existing gas 
supply, electrical supply and venting, and read “Electrical 
Requirements,” “Gas Supply Requirements” and “Venting 
Requirements” before purchasing parts.
Mobile home installations require special parts (listed following) 
that may be ordered by calling the dealer from whom you 
purchased your dryer. For further information, please reference 
the front page of your “Dryer User Instructions.”

Mobile home installation kit. Ask for Part Number 346764.

Metal exhaust system hardware.

WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.

Clear the room, building, or area of all occupants.

In the State of Massachusetts, the following installation instructions apply:

■  

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by 

the State of Massachusetts.

■  

If using a ball valve, it shall be a T-handle type.

■  

A flexible gas connector, when used, must not exceed 3 feet.

8" or 10" pipe wrench

8" or 10" adjustable 
wrench (for gas 
connections)

Flat-blade screwdriver

Adjustable wrench that 
opens to 1" (2.5 cm) or 
hex-head socket wrench 
(for adjusting dryer feet)

Level

¼" nut driver or socket 
wrench

Knife

Safety glasses

Vent clamps

Pipe-joint compound 
resistant to L.P. gas

Caulking gun and 
compound (for installing 
new exhaust vent)

Gloves

Pliers

Содержание WGD5200T

Страница 1: ...ecadora 17 Conexión del suministro de gas 17 Conexión del ducto de escape 18 Cómo invertir el cierre de la puerta opcional 18 Complete la instalación 19 8562582 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell ...

Страница 2: ...ors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 3: ...tion of the dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector NOTE No other fuel burning appliance can be installed in the same closet as a dryer Installation Clearances The location must be large enough to allow the dryer door to open fully Dryer Dimensions Most installations require a minimum 5 14 cm clearance behind the dryer for the exhaust vent w...

Страница 4: ...oor well of your dryer If this information does not agree with the type of gas available contact your dealer or call the phone numbers referenced on the front page of your Dryer User Instructions A Recessed area B Side view closet or confined area C Closet door with vents A B C 18 45 7 cm 1 2 5 cm 29 73 66 cm 1 2 5 cm 1 2 5 cm 14 max 35 6cm 27 70 5 cm 5 14 cm 48 in 310 cm 2 2 24 in 155 cm 2 2 3 7 ...

Страница 5: ...er has been converted to use L P gas L P compatible copper tubing can be used If the total length of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint compounds that resist the action of L P gas must be used Do not use TEFLON tape Dryer Gas Pipe The gas pipe that comes out through the rear of your dryer has a male pipe thread A NPT dryer pipe Burner Input Requirements Elevat...

Страница 6: ... metal or flexible metal vent Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions NOTE The following kits for close clearance alternate installations are available for purchase Please reference the Assistance or Service section of your Drye...

Страница 7: ...raightest path possible See Determine Vent Length Avoid 90º turns Use clamps to seal all joints Do not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent InstallLevelingLegs 1 To protect the floor use a large flat piece of cardboard from the dryer carton Place cardboard under the entire back edge of the dryer See illustration 2 Firmly grasp the...

Страница 8: ...ectVent 1 Using a 4 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 10 2 cm clamp 2 Move dryer into final position Do not crush or kink vent Make sure dryer is level 3 On gas models Check to be sure...

Страница 9: ...rt the door strike you removed in Step 8 in hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 11 Close door and check that door strike aligns with door catch C If needed slide door catch left or right within slot to adjust alignment CompleteInstallation 1 Check to be sure all parts are now installed If there is an extra part go back through the s...

Страница 10: ...l símbolo de advertencia de seguridad y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan INSTRUCCIONES IMPORTANTES DE SEGURIDAD Antes de guardar o descartar su vieja secadora quítele la puerta GUARDE ESTAS INSTRUCCIONES ADVERTENCIA Para su seguridad la información en este manual debe ser observada para minimizar el riesgo de incendio o explosión o para prevenir daños a propiedades her...

Страница 11: ... secadora y carga de 200 lbs 90 7 kg También se debe considerar espacio adicional para otro electrodoméstico que le acompañe Un piso nivelado con un declive máximo de 1 2 5 cm debajo de la secadora completa Si el declive es mayor que 1 2 5 cm instale el Juego de extensión de patas de la secadora Pieza No 279810 La ropa quizás no rote adecuadamente y los modelos con ciclos del sensor automático pos...

Страница 12: ...ren aberturas de ventilación mínimas en la parte superior e inferior de la puerta Se aceptan puertas tipo persianas con aberturas de ventilación equivalentes También se debe considerar espacio adicional para otro electrodoméstico que le acompañe Requisitos de instalación adicionales para las casas rodantes Esta secadora es apropiada para instalaciones en casas rodantes La instalación debe ajustars...

Страница 13: ...a tierra de 3 terminales No quite el terminal de conexión a tierra No use un adaptador No use un cable eléctrico de extensión No seguir estas instrucciones puede ocasionar la muerte incendio o choque eléctrico INSTRUCCIONES PARA LA CONEXIÓN ATIERRA GUARDE ESTAS INSTRUCCIONES Para la conexión de una secadora mediante cable eléctrico conectado a tierra Esta secadora debe estar conectada a tierra En ...

Страница 14: ...al no use tubería de cobre Un adaptador abocinado NPT de por entre el tubo de la secadora y la tubería aprobada de Las longitudes superiores a los 20 pies 6 1 m deberán usar tuberías más largas y un accesorio adaptador de tamaño distinto Si su secadora ha sido convertida para usar gas L P se puede usar tubería de cobre compatible de L P de Si la longitud total de la línea de suministro es mayor qu...

Страница 15: ...vitar que se doble y se tuerza lo cual podría dar lugar a una reducción del flujo de aire y un funcionamiento insuficiente Una capota de ventilación debe tapar el ducto de escape para evitar el ingreso de roedores e insectos a la casa La capota de ventilación debe estar por lo menos a 12 30 5 cm de distancia del piso o de cualquier objeto que pudiese estar en el trayecto del ducto de escape como f...

Страница 16: ... o metal flexible El número de codos utilizados Tipo de capota Los estilos recomendados de capotas de ventilación se ilustran aquí El estilo de capota de ventilación angular que se ilustra a continuación es aceptable Vea en el cuadro de longitudes de ducto de escape uno que vaya de acuerdo con su tipo de capota de ventilación para fijarse en las longitudes máximas del ducto de escape que usted pue...

Страница 17: ...el ducto de escape 6 Una vez que la conección esté hecha y que la secadora esté en su ubicación final quite los postes esquinales y el cartón Para uso en casas rodantes Las secadoras a gas deben ser aseguradas al piso con firmeza La instalación en casas rodantes requiere el Juego de Instalación para casas rodantes Vea Instrucciones para el usuario de la secadora para información sobre cómo ordenar...

Страница 18: ...te para separarla de los tornillos Coloque la puerta encima de la secadora Extraiga los tornillos superiores del gabinete 4 Use un destornillador pequeño de hoja plana para quitar con cuidado los cuatro tapones D de los orificios de la bisagra que están en el lado izquierdo del gabinete Introduzca los tapones en los agujeros de la bisagra en el lado derecho del gabinete 5 Introduzca los tornillos ...

Страница 19: ...con un tornillo 11 Cierre la puerta y asegúrese de que el interruptor de la misma esté alineado con el pestillo de la puerta C Si es necesario deslice el pestillo de la puerta hacia la izquierda o derecha dentro de la ranura a fin de ajustar la alineación Completelainstalación 1 Revise para cerciorarse de que todas las piezas estén instaladas Si hay alguna pieza extra vuelva a revisar todos los pa...

Страница 20: ...l rights reserved Todos los derechos reservados Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A TM DURASAFE es una marca de comercio de Whirlpool EE UU 4 04 Printed in U S A Impreso en EE UU ...

Отзывы: