21
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
1.
Attach power supply cord
strain relief
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fi t with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
2.
Attach power supply cord
to strain relief
4-Wire Power Supply Cord Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit the use of
3-wire connections.
4-wire receptacle
(NEMA type 14-30R)
4-prong plug
Spade terminals
with upturned ends
Ring terminals
Power Supply Cord Connection
Power Supply Cord Strain Relief