9
13.
Connect remaining wires
Connect remaining wires to outer terminal block screws. Tighten
screws. Finally, reinsert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw.
Now, go to
Venting Requirements.
14.
Prepare to connect neutral
ground wire and neutral wire
Direct wire cable must have 5 ft. (1.52 m) of extra length
so dryer may be moved if needed.
4-wIre DIreCT wIre
CONNeCTION
Prepare your 4-wire cable for direct connection:
Strip 5" (127 mm) of outer covering
from end of cable, leaving bare
ground wire at 5" (127 mm).
Cut 1
1
/
2
" (38 mm) from remaining
3 wires. Strip insulation back 1"
(25 mm). Shape ends of wires into
hooks.
To connect wires to terminal block,
place hooked end of wire under
terminal block screw, facing to the
right, squeeze hooked end together
and tighten screw.
15.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire and place hooked end (hook
facing right) of neutral wire (white or center wire) of direct wire
cable under center screw of terminal block. Squeeze hooked
ends together and tighten screw.
Remove center, silver-colored terminal block screw. Remove
neutral ground wire from external ground conductor screw.
16.
Connect ground wire
Connect ground wire (green or bare) of direct wire cable
to external ground conductor screw. Tighten screw.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinsert tab
of terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw.
Now, go to Venting
Requirements.
17.
Connect remaining wires
1"
(25 mm
)
5"
(127 mm)