Screw in leveling legs
28.
diamond
marking
Tighten and adjust leveling legs
32.
CONNeCT VeNT
LeVeL Dryer
Level Dryer
31.
Not Level
LEVEL
Not Level
Check levelness of dryer from side to side. Repeat from
front to back.
Place
level here
Connect vent to exhaust outlet
29.
Move dryer to final location
30.
If dryer is not level, prop up using a wood block, use wrench
to adjust legs up or down, and check again for levelness. Once
legs are level, make sure all four legs are snug against the
ground before tightening them.
After dryer is in place, remove corner posts and cardboard from
under dryer.
Examine leveling legs, find diamond marking. Screw legs into
leg holes by hand, use a wrench to finish turning legs until
diamond marking is no longer visible.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is clean.
Dryer vent must fit over dryer exhaust outlet and inside exhaust
hood. Check that vent is secured to exhaust hood with a 4"
(102 mm) clamp.
Move dryer to final location, taking care not to crush or kink vent.