If there is no continuity, disconnect the white
wire of the harness from the power cord at
the location illustrated in figure 5. Test the
continuity of the power cord neutral wire as
illustrated in figure 6. If an open circuit is
found, replace the power cord. Otherwise,
go to step 6.

6.

In a similar way, check the continuity between
the L1 terminal of the plug and P9-2 (black
wire) on the control board.

If there is continuity, go to step 8.

If there is no continuity, check the continuity
of the power cord in a similar way to that
illustrated in figure 6, but for power cord’s
L1 wire.

If an open circuit is found, replace the power
cord. Otherwise, replace the main harness.

7.

Visually check that the P5 connector is
inserted all the way into the machine control
electronics.

8.

Visually check that the console electronics and
housing assembly is properly inserted into the
front console.

9.

If both visual checks pass, replace the console
electronics and housing assembly.

10.

Plug in dryer or reconnect power.

11.

Perform steps under DIAGNOSTIC: Console
Buttons and Indicators, page 1, to verify repair.

12.

If indicators still do not light, perform
TEST #2.

TEST #2

Machine Control

Power Check

This test is used to determine if power is present
at the machine control electronics. This test
assumes that TEST #1 has been completed.

NOTE:

The drum light is controlled by the machine

control on all models.

1.

Plug in dryer or reconnect power.

2.

Open the door.

If the drum light illuminates, then power
is present at the machine control. Go to
step 3.

If the drum light fails to illuminate, the
problem may be as simple as a bad bulb.
Replace bulb with a working bulb. If drum
light still fails to illuminate, continue with
step 3.

3.

Unplug dryer or disconnect power.

4.

Replace the machine control electronics.

5.

Plug in dryer or reconnect power.

6.

Perform steps under DIAGNOSTIC: Console
Buttons and Indicators, page 1, to verify repair.

TEST #3

Motor Circuit

This test will check the wiring to the motor and the
motor itself. The following items are part of this
motor system:

Part of Motor System

Electric

Dryer

Gas

Dryer

Harness/connection

Thermal fuse

no

Belt/belt switch

Drive motor

Centrifugal switch

Door switch

Machine control electronics. See
ESD information, page 1.

1.

Unplug dryer or disconnect power.

2.

Access the machine control electronics and
measure the resistance across P8-4 and P9-1.
See Accessing & Removing the Electronic
Assemblies, page 9.

If resistance across P8-4 and P9-1 is in
the range of 1 to 6

, replace the machine

control electronics.

Otherwise, go to step 3.

3.

Check the wiring and components in the
path between these measurement points by
referring to the appropriate wiring diagram
(gas or electric) on page 12.

ELECTRIC DRYER ONLY:

Check the thermal

fuse. See TEST #4b, page 7.

ALL DRYERS:

Continue with step 4 below to

test the remaining components in the motor
circuit.

4.

Check the belt switch and drive motor. Access
the belt switch and drive motor by removing
the back panel. See Removing the Back Panel,
page 11. Slowly remove the drum belt from the
spring-loaded belt switch pulley, gently letting
the belt switch pulley down. See figure 7.

5.

Remove the white connector from the drive
motor switch. See figure 8.

6.

Remove the bare copper wire terminal from
pin 5 of black drive motor switch. See figure 9.

7.

Using figure 9, check for the resistance values
of the motor’s Main and Start winding coils as
shown in the following table.

NOTE:

Main and Start winding coils must be

checked at the motor.

Winding

Resistance

Contact Points

of Measurement

MAIN

3.3–3.6

Lt. blue wire in back at pin 4

and bare copper wire

terminal removed from pin 5

of black drive motor switch

START

2.7–3.0

Lt. blue wire in back at pin 4

and bare copper wire

terminal on pin 3 of black

drive motor switch

If the resistance at the motor is correct,
there is an open circuit between the motor
and machine control electronics. Check for
failed belt switch.

If the Start winding resistance is much
greater than 3

, replace the motor.

8.

Check the belt switch by measuring resistance
between the two light blue wires, as shown in
figure 10, page 6, while pushing up the belt
switch pulley.

Main Winding:

Lt.

and Bare Copper Wire

Blue Wire in Back

Start

Winding:

Lt.

and

Bare Copper

Wire

Blue Wire

in Back

1

5

3

4

6

2

Figure 9.

Main and start winding measure

points.

COM

G

L1

L1

Power Cord

Plug

N

N

G

Figure 6.

Power cord terminals, gas dryer.

White

Connector

Drive Motor

Switch

1

5

3

4

6

2

Figure 8.

Remove white connector.

Drum

Belt

Belt Switch Pulley

Figure 7.

Slowly remove drum belt.

Содержание WED9200SQ1

Страница 1: ...urn off then stay on with 8 88 displayed Continue with diagnostics 4 If entry into Diagnostic Test Mode is unsuccessful choose a different button except Pause Cancel and Controls Lock Unlock and repeat step 2 If no indicators come on after repeating step 2 using a different button go to TEST 1 page 4 DIAGNOSTIC Active Fault Codes If there is an active fault code it will be flashing in the display ...

Страница 2: ...ted to indicate the air flow range corresponding to the number displayed The More LED will be illuminated for air flow readings above 40 cfm The Normal LED will be illuminated for air flow readings between 29 and 40 cfm The Less LED will be illuminated for air flow readings less than 29 cfm If air flow value is low Less LED is lit check to make sure the lint screen is clean the door seal is in pla...

Страница 3: ...stor is shorted This fault code appears ONLY when in the Diagnostic Test Mode See TEST 4a page 7 F 26 Motor Drive System Failure F 26 flashes if there is a motor drive system failure See TEST 3 page 5 F 28 Moisture Sensor Open F 28 flashes if the moisture sensor strip is open This fault code appears ONLY when in the Diagnostic Test Mode See TEST 5 page 8 F 29 Moisture Sensor Shorted F 29 flashes i...

Страница 4: ...OSTIC Console Buttons and Indicators page 1 to verify repair 13 If indicators still do not light perform TEST 2 page 5 GAS DRYER 1 Unplug dryer or disconnect power 2 Remove the cover plate from the top right corner of the back of the dryer See figure 3 3 Check that the power cord is firmly connected to the dryer s wire harness See figure 5 4 Access the machine control electronics without disconnec...

Страница 5: ...on Thermal fuse no Belt belt switch Drive motor Centrifugal switch Door switch Machine control electronics See ESD information page 1 1 Unplug dryer or disconnect power 2 Access the machine control electronics and measure the resistance across P8 4 and P9 1 See Accessing Removing the Electronic Assemblies page 9 If resistance across P8 4 and P9 1 is in the range of 1 to 6 Ω replace the machine con...

Страница 6: ... cut off high limit thermostat and heater If connections look good check for continuity across each of these components Replace the heater if it is electrically open Replace both the thermal cut off and inlet thermistor high limit thermostat assembly if either the thermal cut off or the high limit thermostat is electrically open 5 If no open circuit is detected remove the P4 connector then measure...

Страница 7: ...let temperature using an inlet thermistor that is part of the high limit thermostat assembly 1 Activate the Diagnostic Test Mode See procedure on page 1 2 If F 24or F 25is a displayed error in the Diagnostic Test Mode the inlet thermistor or wire harness is either open or shorted Unplug dryer or disconnect power Check wire connections at the machine control electronics and inlet thermistor See Acc...

Страница 8: ...If a small resistance is not measured continue with step 8 8 Measure the resistance across each of the outermost contacts and the center terminal ground connection If a resistance less than infinity is measured replace the sensor harness 9 If moisture sensor diagnostic test passes check the thermistor Perform TEST 4a page 7 If the problem persists after replacing the moisture sensor and thermistor...

Страница 9: ...ber appears in the display If any of the preceding conditions are not met 1 Unplug dryer or disconnect power 2 Check that the wires between the door switch and machine control electronics are connected See figure 13 for switch location and see Accessing Removing the Electronic Assemblies at right If the connections are OK replace the wire and door switch assembly and retest If wire and door switch...

Страница 10: ...the machine control 2 Remove the screw that fastens the assembly to the machine control mounting bracket figure 16 page 9 and the two screws that fasten the console assembly to the dryer figure 18 5 The console mounting bracket is fastened to the console front panel with two latches at both sides of the console assembly Unlatch the bracket gently with a screwdriver while pulling the mounting brack...

Страница 11: ...698 6047486 6199300 6446357 6597144 6604298 6685241 6732447 6784673 6819255 D314261 D314262 D457991 D457992 D495453 REMOVING THE BACK PANEL 1 Unplug dryer or disconnect power 2 Remove the two rear screws from the top panel and slide the top panel to the rear to remove 3 Remove the cover plate disconnect the power cord and remove ground screw 4 Remove the metal spring clip between the back panel an...

Страница 12: ...IVE MOTOR 1 3 H P MAIN 3 3 3 6 START 2 7 3 0 SENSOR DOOR NEUTRAL MOTOR MTR CS MOIST MOIST RTN MODEL MODEL RTN OUTLET TEMP OUTLET TEMP RTN MACHINE CONTROL ELECTRONICS Y R P13 1 P13 2 P4 4 P4 5 P4 3 P4 6 R OUTLET THERMISTOR 10 k P9 2 L1 BR L1 LINE BK HEATER V HEATER RTN N O COM BK BK BK R R W NC HIGH LIMIT THERMOSTAT 295 F 146 C THERMAL CUT OFF 352 F 178 C HEATER 7 8 11 8 DRUM LAMP G Y P4 2 INLET TE...

Отзывы: