FOR SERVICE TECHNICIAN’S USE ONLY
PART NO. W10156037A
TECH SHEET - DO NOT DISCARD
PAGE 2
Rotating knob turns
indicators on or off.
“Less Time” button
turns the right digit of
the display on or off.
“More Time” button
turns the left digit of
the display on or off.
Dryness button controls
all indicators above button.
Temperature button controls
all indicators above button.
Turns off all indicators and
exits diagnostic mode.
Each button controls
its own indicator.
Power button controls
Status indicators at right.
Start button turns on dryer.
Figure 1.
Console Diagnostics.
DIAGNOSTIC: Displaying Inlet Air Flow
Used to display the air flow value at the inlet of the heater box being measured by
the machine control.
After all saved fault codes have been displayed, press the Wrinkle Shield button to
activate air flow detection. A 30 or 50 second countdown timer will start and the
dryer will turn on.
➔
If the dryer is cold, the countdown will start at 50 seconds.
NOTE:
If the dryer is extremely cold (less than 40°F [4.4°C]) the air flow may
not be detected properly, and “--” will be displayed.
➔
If the dryer is hot, the countdown timer will start at 30 seconds (cool down
period) followed by an additional 50 second countdown.
A Dryness modifier LED will also be illuminated to indicate the air flow range
corresponding to the number displayed.
■
The More LED will be illuminated for air flow readings above 40 cfm.
■
The Normal LED will be illuminated for air flow readings between 29 and 40 cfm.
■
The Less LED will be illuminated for air flow readings less than 29 cfm.
➔
If air flow value is low, check to make sure the lint screen is clean, the door
seal is in place and the vent is not obstructed.
DIAGNOSTIC: Displaying Line Voltage
Used to display the line voltage currently being measured by the machine control:
After all saved fault codes have been displayed, press the End of Cycle Signal
button. The last 2 digits of the voltage value will be displayed on the dual
7-segment display.
A Dryness modifier LED will also be illuminated to indicate the voltage range
corresponding to the number displayed. The Dryness LEDs relate to specific
voltage ranges as follows:
■
The More LED will be illuminated for high voltage readings (above 260 VAC).
■
The Normal LED will be illuminated for normal voltage readings (200-260 VAC).
■
The Less LED will be illuminated for low voltage readings (below 200 VAC).
➔
If the line voltage is not seen on L2 the display will flash
L2
.
Go to TEST #1, page 4.
DEACTIVATING THE DIAGNOSTIC TEST MODE
Press the Pause/Cancel button twice to exit diagnostics.
ACTIVATING THE MANUAL LOAD TEST
1.
Be sure the dryer is in standby mode (plugged in with all indicators off, or
with only the Done indicator on).
2.
Select any one button (except Pause/Cancel) and follow the steps below,
using the same button (remember the button):
Press/
hold 2-5
seconds
➔
Release
for 2-5
seconds
➔
Press/
hold 2-5
seconds
➔
Release
for 2-5
seconds
➔
Press/
hold 2-5
seconds
➔
Release
for 2-5
seconds
➔
Press/
hold 2-5
seconds
88
flashes momentarily, the motor starts right away, and the Heavy Duty LED
flashes (this step starts the Manual Load sequence):
1. Turn on motor.
➔
Flash “Heavy Duty” LED.
Now press any key (except Pause/Cancel) and the control will advance through
each step of the following sequence:
Single Element Model
2. Motor + heater.
➔
Flash “Casual” LED.
3. No loads on (motor + heater).
➔
Flash “Normal” LED.
4. Repeat using same button.
➔
Start sequence again at 1.
Dual Element Model
2. Motor + heater 1.
➔
Flash “Casual” LED.
3. Motor + heater 2.
➔
Flash “Timed Dry” LED.
4.
Motor + heater 1 + heater 2 +
drum light.
➔
Flash “Drum Light” LED.
5. No loads on (motor + heaters).
➔
Flash “Normal” LED.
6. Repeat using same button.
➔
Start sequence again at 1.