Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and 
36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.

NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 
cabinet is covered by not less than 

¹⁄₄

" (0.64 cm) flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an uncovered wood or metal cabinet.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate and wire gauge is in accordance 
with local codes.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.

This range is manufactured with the neutral terminal connected 
to the cabinet. Use a 3-wire, UL listed, 40-amp power supply 
cord (pigtail); or if local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 amps and investigated for use with ranges.

Electrical Connection

To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. (The model/serial number rating plate is located on the 
oven frame behind the storage drawer panel.)

When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz, 
AC only electrical supply is available, a 50-amp maximum 
circuit protection is required (or, if specified on the model/
serial rating plate, when a 4-wire or 3-wire single phase 
120/208 volt 60 Hz, AC only electrical supply is available, a 
40- or 50-amp maximum circuit protection is required), fused 
on both sides of the line.

A time-delay fuse or circuit breaker is recommended.

The range can be connected directly to the fused disconnect 
(or circuit breaker box) through flexible or nonmetallic 
sheathed, copper or aluminum cable. See “Electrical 
Connection.”

Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.

A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).

Wire sizes and connections must conform with the rating of 
the range (40 amps).

The wiring diagram is located on the underside of the storage 
drawer or below the warming drawer in a clear plastic bag.

A. 13" (33.0 cm) upper 

cabinet depth

B. 30" (76.2 cm) min. 

opening width

C. For minimum clearance 

to the top of the cooktop,
see NOTE.

D. 23

¹⁄₄

" (59.1 cm) opening 

depth

E. 30" (76.2 cm) min. 

opening width

F. Junction box - 5.5" (14.0 cm) min. 

from either cabinet, 10" (25.4 cm) 
max. from floor
Outlet must be flush.
Nothing located in shaded 
area can extend more than 
2" (5.1 cm) from wall or range will 
not slide all the way back.

G. Cabinet door or hinge should not 

extend into cutout.

H. 18" (45.7 cm) minimum clearance

I. 3" (7.6 cm) minimum clearance to 

cabinet wall

A

D

E

F

G

H

B

I

I

C

Содержание W10430946A

Страница 1: ...vel Range 13 Complete Installation 13 Moving the Range 14 SÉCURITÉ DE LA CUISINIÈRE 16 EXIGENCES D INSTALLATION 17 Outillage et pièces 17 Exigences d emplacement 17 Spécifications électriques Canada seulement 19 Préparation du plan de travail 19 INSTRUCTIONS D INSTALLATION 20 Déballage de la cuisinière 20 Réglage des pieds de nivellement 20 Installation de la bride antibasculement 21 Vérifier que ...

Страница 2: ... the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not ...

Страница 3: ...clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damage ...

Страница 4: ...use a 4 wire power supply cord rated at 250 volts 40 amps and investigated for use with ranges Electrical Connection To properly install your range you must determine the type of electrical connection you will be using and follow the instructions provided for it here Range must be connected to the proper electrical voltage and frequency as specified on the model serial number rating plate The mode...

Страница 5: ...rs with ring terminals or open end spade terminals with upturned ends terminating in a NEMA Type 10 50P plug on the supply end Connectors on the appliance end must be provided at the point the power supply cord enters the appliance This uses a 3 wire receptacle of NEMA Type 10 50R ElectricalRequirements CanadaOnly If codes permit and a separate ground wire is used it is recommended that a qualifie...

Страница 6: ...ntly lay it on its back on the cardboard corners 7 Pull cardboard bottom firmly to remove 8 Use an adjustable wrench to loosen the leveling legs 9 Place cardboard or hardboard in front of range Using 2 or more people stand range back up onto cardboard or hardboard AdjustLevelingLegs 1 If range height adjustment is necessary use a wrench or pliers to loosen the 4 leveling legs This may be done with...

Страница 7: ... determined mounting method See the following illustrations 5 Using the Phillips screwdriver mount anti tip bracket to the wall or floor with the two 12 x 1 screws provided WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket...

Страница 8: ...the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord Power Supply Cord Direct Wire WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electri...

Страница 9: ...hten strain relief screw against the flexible conduit 5 Replace back panel and screws on rear of range 6 Complete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available REMOVE TAG USE NUTS WITH POWER CORD NUTS WITH POWER CORD QUITE LA ETIQUETA USE LAS TUERCAS PARA CONECTAR EL CORDÓN ELÉCTRICO REMOVE TAG USE NUTS WITH POWER CO...

Страница 10: ... to the outer terminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover If your home has And you will be connecting to G...

Страница 11: ... directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires Strip the insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical su...

Страница 12: ...ex nuts 7 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 8 Securely tighten hex nuts 9 Replace terminal block access cover 3 wire connection Direct Wire Use this method only if local codes permit connecting ground conductor to neutral supply wire 1 Pull the conduit through the hole and conduit plate on bottom of range Allow enough slack to easily at...

Страница 13: ...gs up or down until range is level Push range back into position 5 Check that rear leveling leg is engaged in anti tip bracket NOTE Range must be level for satisfactory baking performance CompleteInstallation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all pac...

Страница 14: ... cord into a grounded outlet 5 Slide range back so rear range foot is under anti tip bracket 6 Refer to the Verify Anti Tip Bracket Is Installed and Engaged section to verify engagement 7 Check that range is level For direct wired ranges 1 Disconnect power 2 Slide range forward 3 Complete cleaning or maintenance 4 Slide range back so rear range foot is under anti tip bracket 5 Refer to the Verify ...

Страница 15: ...15 Notes ...

Страница 16: ...ANGER ou AVERTISSEMENT Ces mots signifient Risque de basculement Un enfant ou une personne adulte peut faire basculer la cuisinière ce qui peut causer un décès Fixer la bride antibasculement au plancher ou au mur conformément aux instructions d installation Faire glisser de nouveau la cuisinière de façon à ce que le pied arrière de la cuisinière se trouve dans la fente de la bride antibasculement ...

Страница 17: ...valeurs minimales des dégagements de séparation La bride antibasculement de plancher doit être installée Pour l installation de la bride antibasculement expédiée avec la cuisinière voir la section Installation de la bride antibasculement Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques IMPORTANT Pour éviter d endommager les placards consult...

Страница 18: ...mm aluminium 0 024 0 6 mm ou cuivre 0 020 0 5 mm Distance de séparation de 30 76 2 cm ou plus entre le dessus de la table de cuisson et le fond d un placard de bois ou de métal non protégé A 30 78 1 cm B Hauteur jusqu à la partie inférieure de la table de cuisson avec les pieds de nivellement complètement abaissés 35 90 8 cm C Plaque signalétique située sur le côté droit du châssis du four derrièr...

Страница 19: ...mplacement définitif de la cuisinière Ne pas utiliser de câble de rallonge Préparationduplandetravail pourcuisinièresencastrablesuniquement Les bords latéraux de la table de cuisson de la cuisinière encastrable seront placés en chevauchement sur les extrémités du plan de travail Si la largeur de l espace disponible est de 30 76 2 cm et si la rive avant du plan de travail est plane et à l équerre a...

Страница 20: ...eds de nivellement Ceci doit être effectué alors que la cuisinière repose sur sa partie postérieure ou qu elle est supportée par 2 pieds après avoir été replacée en position verticale REMARQUE Pour placer à nouveau la cuisinière en position verticale placer un carton ou un panneau de fibres dur devant la cuisinière À l aide de deux personnes ou plus relever la cuisinière et la placer sur le carton...

Страница 21: ...t bieninstalléeetengagée 1 Retirer le tiroir de remisage Voir la section Tiroir de remisage 2 Au moyen d une torche électrique inspecter le dessous de la cuisinière 3 Inspecter la cuisinière pour vérifier que le pied arrière de la cuisinière se trouve dans la fente de la bride antibasculement A Axe central B 14 36 2 cm Risque de basculement Un enfant ou une personne adulte peut faire basculer la c...

Страница 22: ...e qui suit Les fusibles du domicile sont intacts et serrés le disjoncteur ne s est pas déclenché La cuisinière est branchée sur une prise électrique La prise de courant est correctement alimentée Consulter la section Dépannage dans le Guide d utilisation et d entretien ou les instructions d utilisation Après 5 minutes de fonctionnement de la cuisinière vérifier la présence de chaleur Si la cuisini...

Страница 23: ...23 Notes ...

Страница 24: ...W10430946A 2012 All rights reserved Tous droits réservés 1 12 Printed in U S A Imprimé aux É U ...

Отзывы: