manualshive.com logo in svg
background image

3

Product dimensions

Venting requirements

29-7/8" (75.9 cm) model: RH3730
35-7/8" (91.1 cm) model: RH3736

7-1/2" 

(19.1 cm)

2" 

(5.1 cm)

1-1/2" 

(3.8 cm)

1" 

(2.5 cm)

1-1/2" 

(3.8 cm)

6" 

(15.2 cm)

9" 

(22.9 cm)

12" 

(30.5 cm)

3/4" 

(1.9 cm)

3/8" 

(9.5 mm)

17-1/2" 

(44.5 cm)

Electrical Code ANSI/NFPA 70 —
latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code
Part 1 and C22.2 No. 0-M91 - latest
edition** and all local codes and
ordinances.

A U.L.- or C.S.A.-listed conduit
connector must be provided at each
end of the power supply cable (at
the range hood and at the junction
box).

In U.S. only: For power cord
connected installations, a U.L.-
listed range hood cord-connection
kit MUST be used. Cord kit has not
been evaluated for use in Canada.

Copies of the standards listed may be 
obtained from:

*  National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

Venting system must terminate to
the outside.

Do not terminate the vent in an attic
or other enclosed space.

Do not use four-inch (10.2 cm)
laundry-type wall caps.

Do not use plastic vent.

Vent system needed for installation
is not included.

Determine which outside venting
method needs to be used. It is
recommended that the vent
system be installed before
installing the hood.

NOTE: If a non-vented
(recirculating) installation is
desired, follow instructions on
Page 5.

The length of the vent system and
number of elbows should be kept
to a minimum to provide efficient
performance. The size of the vent
system should be uniform. Do
Not install two elbows together.
Use duct tape to seal all joints in
the vent system. Vent system can
terminate either through the roof
or wall. Use caulking to seal
exterior wall or roof opening
around exhaust hood. For the
most efficient and quiet operation,
it is recommended that the range
be vented vertically through the

Figure 1

7" (17.8 cm) round 
or  3-1/4" x 10" 
(8.3 x 25.4 cm)
through roof

roof cap

24" (61.0 cm) to 
30" (76.2 cm) above
cooking surface

Round vent: Use 7"
(17.8 cm) round damper
(purchased separately) 

Vertical roof venting

wall
cap

3-1/4" x 10"
(8.3 x 25.4 cm)
through the wall

Horizontal wall venting

7" (17.8 cm) round 
or 3-1/4" x 10" 
(8.3 x 25.4 cm)
through the wall

24" (61.0 cm) to 
30" (76.2 cm) above
cooking surface

Figure 2

Recommended vent length

Use 3-1/4" x 10" (8.3 x 25.4 cm)
with a maximum vent length of
35 feet (10.7 m) or 7" (17.8 cm)
round vent with a maximum
length of 50 feet (15.2 m) for vent
system. For best performance,
use no more than three 90°
elbows. To calculate the length of
system you need, add the
equivalent feet (meters) for each
vent piece used in the system.
See the examples on the next
page.

roof through 7" (17.8 cm) round
vent system.

Figures 1 and 2 show common
venting methods and what types
of materials are needed.

YL20378/8285186  6/18/02  10:42 AM  Page 3

Содержание RH3730 Series

Страница 1: ...stallation Instructions for local electrical inspector s use Part No 626918A 8285186 Pièce N 626918A 8285186 RH3730 Series RH3736 Series www whirlpool com Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance or Service 2 2 3 3 4 6 7 8 8 9 10 30 76 2 cm and ...

Страница 2: ...itioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be grounded flat blade screwdriver pliers drill ruler 1 1 4 3 0 cm drill bit 1 8 or 3 mm drill bit for pilot holes...

Страница 3: ...od NOTE If a non vented recirculating installation is desired follow instructions on Page 5 The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance The size of the vent system should be uniform Do Not install two elbows together Use duct tape to seal all joints in the vent system Vent system can terminate either through the roof or wall Use c...

Страница 4: ...4 cm to 7 17 8 cm 4 5 ft 1 4 m 90 elbow 5 ft 1 5 m 45 elbow 2 5 ft 0 8 m 3 1 4 x 10 8 3 x 25 4 cm to 7 17 8 cm 90 elbow 5 ft 1 5 m 7 17 8 cm wall cap 0 ft 0 m Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering Cover countertop cooktop or set in range with a thick protective covering to prevent damaging them 1 Disconnect and move freestandin...

Страница 5: ...onnector and screws aside for use if connecting to a rectangular vent system For vented installations go to Step 7a For non vented installations go to Step 7c 1 1 2 3 8 cm 5 1 2 14 cm centerline wall 5 1 4 13 3 cm 7 1 2 19 1 cm 2 5 1 cm 1 1 4 3 2 cm dia hole 3 1 4 x 10 8 3 x 25 4 cm HORIZONTAL vent system 1 8 3 2 mm 3 3 4 9 5 cm centerline cabinet front 5 1 4 13 3 cm 7 1 2 19 1 cm 3 4 19 mm 1 1 4 ...

Страница 6: ...ure damper operates freely 14 Direct wiring Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist on connectors Connect the power supply ground wire to the green ground screw inside the terminal box Use caulking to seal wire opening Replace terminal box cover Using a U L listed power supply cord connection kit U S only Follow Power Cord Kit...

Страница 7: ...securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Al...

Страница 8: ...To clean filter light lens Place filter light lens in dishwasher or hot sudsy water to clean Non vented installation Turn filter light lens so that charcoal filter pad is facing up Lift tabs and remove charcoal filter pad Discard charcoal filter pad if it needs replacing Place filter light lens in dishwasher or hot sudsy water to clean Lift tabs and place charcoal filter pad in filter light lens T...

Страница 9: ... area call our Customer Interaction Center telephone number your nearest authorized service center or Whirlpool Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone numb...

Страница 10: ...UEBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Inglis Limited with any questions or concerns at Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga Ontario L5N 3A7 Please include...

Страница 11: ... d installation à l intention de l inspecteur local des installations électriques Pièce N 626918A 8285186 Part No 626918A 8285186 www whirlpool com Consultation rapide Table des matières Pages Avant de commencer Spécifications pour l installation électrique Dimensions du produit Circuit de décharge de l air Les étapes de l installation Utilisation et entretien Garantie Demande d assistance ou de s...

Страница 12: ...m 1 1 4 po foret de 3 mm 1 8 po pour les avant trous crayon Matériel nécessaire pour l installation avec décharge à l extérieur compas ou gabarit circulaire de 20 3 cm 8 po cisaille de ferblantier scie à guichet scie sauteuse ruban adhésif pour conduit clapet rond de 17 8 cm 7 po pour un conduit d évacuation de diamètre 17 8 cm 7 po Placards avec fond en retrait tringles de remplissage de largeur ...

Страница 13: ...tiliser une bouche de décharge murale de 10 2 cm 4 po normalement utilisée pour un équipement de buanderie Ne pas utiliser des conduits de plastique Le système d évacuation nécessaire pour l installation n est pas inclus Déterminer la méthode appropriée pour la décharge à l extérieur On recommande que le conduit de décharge soit installé avant l installation de la hotte NOTE Pour une configuration...

Страница 14: ...au protecteur épais sur la table de cuisson ou le plan de travail pour la protection contre les dommages et souillures 3 Si le placard comporte un fond en retrait ajouter une tringle de remplissage de chaque côté Positionner les vis de fixation des tringles aux emplacements indiqués 2 Déterminer quelle méthode de décharge de l air sera utilisée à travers le toit à travers le mur ou sans évacuation...

Страница 15: ...tangulaire supérieur et les opercules semi circulaires 7b Pour un conduit d évacuation rectangulaire installer le raccord rectangulaire clapet Note Si la bouche de décharge murale est située directement derrière le raccord on doit veiller à ce qu il n y ait PAS d interférence entre le clapet dans le raccord et la bouche de décharge 10 Prendre les 4 vis de montage dans le sachet de petites pièces p...

Страница 16: ... ventilateur et des lampes Vérifier que le volet de réglage peut manœuvrer librement 14 Raccorder les conducteurs du câble d alimentation de la hotte aux conducteurs de même couleur du circuit électrique avec des connecteurs vissables blanc blanc et noir noir Ensuite connecter le conducteur de liaison à la terre à l intérieur de la boîte de connexion de la hotte avec la vis verte Assurer l étanché...

Страница 17: ...t à la quantité des aliments à préparer et à la taille de l élément chauffant AVERTISSEMENT POUR RÉDUIRE LE RISQUE DE DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIÈRE APPLIQUER LES RECOMMANDATIONS SUIVANTES Placer sur le récipient un couvercle bien ajusté une tôle à biscuits ou un plateau métallique POUR ÉTOUFFER LES FLAMMES puis éteindre le brûleur VEILLER À ÉVITER ...

Страница 18: ...u chaude savonneuse Installation avec recyclage Orienter l ensemble filtre diffuseur pour placer le filtre à charbon vers le haut pour exposer le filtre Tirer vers le haut sur les pattes et retirer le filtre à charbon On doit jeter le filtre à charbon et installer un filtre neuf Pour le nettoyage placer le filtre diffuseur dans le lave vaisselle ou dans de l eau chaude savonneuse Tirer sur les pat...

Страница 19: ...ez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine Whirlpool en composant le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez écrire en soumettant toute question ou problème au Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indi...

Страница 20: ... en ONTARIO QUÉBEC Montréal à l exception de la rive sud 1 800 361 3032 Rive Sud Montréal 1 800 361 0950 Québec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE L ATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin d autre d assistance vous pouvez écrire à Inglis Ltée en soumettant toute question ou préoccupation au Service des relations avec la clientèle Inglis Ltée 1901 Min...

Отзывы: