38
NEW DESIGN
14 cu. ft. Top-Mount
Air Circulation
The evaporator fan circulates air inside of the refrigerator and freezer section.
(Fig. 45) Most of the air
circulates in the freezer compartment, where it travels to the front and passes through the series of
slots in the inner floor. The air then travels toward the back of the freezer between the inner floor and
the liner, where it passes under the evaporator cover, across the evaporator coils and back into the
freezer through a series of slots in the air tower.
Some of the air in the air tower travels down the chimney into the refrigerator compartment, and is
discharged through the front (narrow slot) and back (wide slot) of the diffuser.
(Fig. 45, INSET) The
fan draws circulating air from the refrigerator through two return air ducts at the back of the separator.
From there the air travels up behind the evaporator cover and across the evaporator coils.
The fan again forces the air into the freezer and refrigerator compartments, to complete the cycle.
Fig. 45
RETURN
AIR DUCT
EVAPORATOR
COVER
EVAPORATOR FAN
AIR TOWER
INNER
FLOOR
EVAPORATOR
SEPARATOR
RETURN
AIR DUCT
INSET
AIR FLOW
TOWARDS
BACK
AIR FLOW
TOWARDS
FRONT
NARROW
SLOT
WIDE
SLOT
DIFFUSER
Содержание MID-LINE DESIGN
Страница 6: ...VI NOTES ...
Страница 18: ...12 MULLION EVAPORATOR DESIGN 12 cu ft Top Mount NOTES ...
Страница 32: ...26 OLD DESIGN 12 14 cu ft Top Mount REFRIGERATOR LIGHT CIRCUIT MULLION HEATER CIRCUIT ...
Страница 73: ...67 MID LINE DESIGN 16 thru 22 cu ft Top Mount WIRING DIAGRAM Direct Neutral Path to Defrost Timer Motor ...
Страница 76: ...70 MID LINE DESIGN 16 thru 22 cu ft Top Mount NOTES ...
Страница 107: ...VII ...
Страница 108: ...VIII CORPORATION ...