background image

Recommended Vent Length

A 3

¹⁄₄

"

 x 10

"

 (8.3 x 25.4 cm) rectangular or 6

"

 (15.2 cm) round vent 

should be used.
The total length of the vent system including straight vent, 
elbow(s), transitions and wall or roof caps must not exceed the 
equivalent of 140 ft (42.7 m) for either type of vent. See 
“Recommended Standard Fittings” section for equivalent lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent 
lengths of each vent piece used in the system. See the following 
examples:

3

¹⁄₄

" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

6" (15.2 cm) vent system = 73 ft (22.2 m) total

If the existing vent is round, a rectangular to round transition piece 
must be used. In addition, a rectangular 3" (7.6 cm) extension vent 
between the damper assembly and rectangular to round transition 
piece must be installed to keep the damper from sticking.

ASSISTANCE

Call your authorized dealer or service center. When you call, you will need the microwave oven model number and serial number. Both 
numbers can be found on the model and serial number plate, which is located behind the microwave oven door on the front frame of 
the microwave oven.

If you need additional assistance, call us at our toll free number or visit our website listed in the Use and Care Guide.

Replacement Parts

If any of the installation hardware needs to be replaced, call us at 
our toll free number listed in the User Instructions.
Following is a list of available replacement parts. You will need 
your model number located on the front facing of the microwave 
oven opening, behind the door.

Damper Assembly

Mounting Plate

Upper Cabinet Template

Mounting Screw Kit (includes parts A-G in “Parts Supplied” in 
the “Tools and Parts” section)

Accessories

Filler Panel Kits are available from your dealer to use when 
installing this microwave oven in a 36" (91.4 cm) or 42" (106.7 cm) 
wide opening. The filler panels come in pairs. Each panel is 3" 
(7.6 cm) wide.

A. Filler panels

See your authorized dealer or service center for details.

A. One 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)

B. 1 wall cap = 40 ft (12.2 m)

C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A                                          B

C

6 ft (1.8 m)

2 ft

(0.6 m)

A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)

C. 1 rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A                                                                  B

C                                  D

6 ft (1.8 m)

2 ft

(0.6 m)

Filler Panel Kit Number

8171336 
8171337 
8171338 
8171339 
99403

White 
Black
Biscuit
Stainless Steel
Almond

A

W10191951A
SP PN W10191955A

© 2008.

All rights reserved.

461965617426

4/08

Printed in China

Содержание MH1160XSQ

Страница 1: ...unting Plate to Wall 8 Prepare Upper Cabinet 8 Install Damper Assembly 9 Install the Microwave Oven 9 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 Accessories 12 W10191951A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential haz...

Страница 2: ...ft sidewall make sure there is at least 6 15 2 cm of clearance between the wall and the microwave oven so that the door can open fully Some cabinet and building materials are not designed to withstand the heat produced by the microwave oven for cooking Check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damages Special Requ...

Страница 3: ...round prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the elect...

Страница 4: ... wall or roof venting changes must be made to the venting system NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used Wall Venting Installation Only 1 Remove screws attaching damper plate to top of microwave oven exterior Slide...

Страница 5: ...e top of microwave oven and flat sides of blower motor face back of microwave oven Lower blower motor back into microwave oven IMPORTANT If blower motor is not positioned with flat sides facing the back of the microwave oven as shown performance will be poor 6 Reattach blower motor to back of microwave oven with 2 screws removed in Step 3 of Wall Venting Installation Only Securely tighten screws N...

Страница 6: ...tions show examples of preferred installation configurations with the mounting plate No Wall Studs at End Holes Figure 1 No Wall Studs at End Holes Figure 2 NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done Wall Stud at One End Hole Figure 3 Wall Studs at Both End Holes Figure 4 A End holes on mou...

Страница 7: ... plate closest to the wall stud centerline s See figures 1 2 and or 3 in Possible Wall Stud Configurations in Locate Wall Stud s section The blackened holes in the shaded areas are ideal hole locations 7 Set the mounting plate aside Wall Venting Installation Only 8 Mark the centerline 3 8 1 cm down from the bottom edge of the upper cabinet 9 Using measuring tape measure out 6 15 2 cm on both sides...

Страница 8: ...ing plate facing forward insert a 1 4 20 x 3 round head bolt through the end hole that fits over the 3 4 19 mm hole drilled in Step 3 of Installation for Wall Stud at One End Hole in the Drill Holes in Rear Wall section 2 Start a toggle nut on the bolt from the back of the mounting plate Leave enough space for the toggle nut to go through the wall and to open 3 Position mounting plate on the wall ...

Страница 9: ... the microwave oven is the heavy side Handle the microwave oven gently 1 Place a washer on each 1 4 20 x 3 flat head bolt and place inside upper cabinet near the 3 8 10 mm holes 2 Make sure the microwave oven door is closed and taped shut 3 Using 2 or more people lift microwave oven and hang it on support tabs at the bottom of mounting plate NOTE To avoid damage to the microwave oven do not grip o...

Страница 10: ...heet metal screw NOTE The screw cannot be installed if the damper assembly is not positioned as shown 2 Connect vent to damper assembly CompleteInstallation 1 Refer to the Use and Care Guide for instructions on how to install filters into your model 2 Plug microwave oven into grounded 3 prong outlet 3 Reconnect power 4 Check the operation of microwave oven by placing 1 cup 250 mL of water on the t...

Страница 11: ...amper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the transition piece See Rectangular to Round Transition illustration Rectangular to Round Transition NOTE The minimum 3 7 6 cm clearance must exist between the top of the microwave oven and the rectangular to round tr...

Страница 12: ...ven If you need additional assistance call us at our toll free number or visit our website listed in the Use and Care Guide ReplacementParts If any of the installation hardware needs to be replaced call us at our toll free number listed in the User Instructions Following is a list of available replacement parts You will need your model number located on the front facing of the microwave oven openi...

Отзывы: