13

Determine vent length and elbows needed for best 
drying performance

Use the Vent system chart below to determine type of vent 
material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the 
Vent system chart. Exhaust systems longer than those 
specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and 
increased energy usage.

The Vent system chart provides venting requirements that will help 
to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn 
inside the dryer. To determine maximum exhaust length, add one 
90º turn to the chart.

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior 

wall opening around exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust 

hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

3. Run vent to dryer location. Use the straightest path possible. 

See “Determine vent path” in “Plan Vent System.” Avoid 90º 
turns. Use clamps to seal all joints. Do not use duct tape, 
screws or other fastening devices that extend into the interior 
of the vent to secure vent.

Install Leveling Legs

1. To protect the floor, use a large, flat piece of cardboard from 

the dryer carton. Place cardboard under the entire back side 
of the dryer. 

2. Firmly grasp the body of the dryer (not the top or console 

panel). Gently lay the dryer on the cardboard. See illustration.

3. Examine the leveling legs. Find the diamond marking. 

4. Screw the legs into the leg holes by hand. Use a wrench to 

finish turning the legs until the diamond marking is no longer 
visible.

5. Place a carton corner post from dryer packaging under each 

of the 2 dryer back corners. Stand the dryer up. Slide the 
dryer on the corner posts until it is close to its final location. 
Leave enough room to connect the exhaust vent.

Level Dryer

Check the levelness of the dryer. Check levelness first side to 
side, then front to back.

If the dryer is not level, prop up the dryer using a wood block. Use 
a wrench to adjust the legs up or down and check again for 
levelness.

Connect Vent

1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 

dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Check that the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible 

gas line.

4. Once the exhaust vent connection is made, remove the corner 

posts and cardboard.

Number of 
90º turns 
or elbows

Type of
vent

Box or 
louvered 
hoods

Angled
hoods

0

Rigid  metal
Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid  metal
Flexible metal

54 ft (16.5 m) 
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid  metal
Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid  metal
Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid  metal
Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

Содержание MEDC400VW - Centennial Electric Dryer

Страница 1: ...nt 17 Spécifications électriques Canada 18 Exigences concernant l évacuation 19 Planification du système d évacuation 20 Installation du système d évacuation 21 Installation des pieds de nivellement 21 Mise à niveau de la sécheuse 22 Raccordement du conduit d évacuation 22 Inversion du sens d ouverture de la porte facultatif 22 Achever l installation 23 You can be killed or seriously injured if yo...

Страница 2: ...d within 2 ft 61 cm of either side of the dryer See Electrical Requirements A sturdy floor to support the total weight dryer and load of 200 lbs 90 7 kg The combined weight of a companion appliance should also be considered A level floor with a maximum slope of 1 2 5 cm under entire dryer If slope is greater than 1 2 5 cm install Extended Dryer Feet Kit Part Number 279810 Clothes may not tumble pr...

Страница 3: ...outside air into the dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening Electrical Requirements U S A It is your responsibility To contact a qualified electrical installer To be sure that the electrical connection is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances The ...

Страница 4: ...power supply cord at least 4 ft 1 22 m long must have 4 10 gauge solid copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover If your outlet looks like this 3 wire receptacle 10 30R Then choose a 3 wire power supply cord with ring or spade terminals and UL listed strain re...

Страница 5: ...nded that you use Power Supply Cord Replacement Part Number 3394208 For further information please reference the service numbers located in the Dryer User Instructions WARNING Electrical Shock Hazard Plug into a grounded 4 prong outlet Failure to do so can result in death or electrical shock GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For a grounded cord connected dryer This dryer must be groun...

Страница 6: ...ust be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock WARNING Fire Hazard Use 10 gauge solid copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center t...

Страница 7: ...ed 3 wire if 4 wire is not available Electrical Connection Options If local codes do not permit the connection of a cabinet ground conductor to the neutral wire go to Optional 3 wire connection section 4 wire connection Power Supply Cord IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections A Removable conduit connector B Hole ...

Страница 8: ...nal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire of direct wire c...

Страница 9: ...connections Now go to Venting Requirements 3 wire connection Direct Wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 3 8 9 cm of outer covering from end of cable Strip insulation back 1 2 5 cm If using 3 wire cable with ground wire cut bare wire even with outer coverin...

Страница 10: ...nter silver colored terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and the neutral wire white or center wire of power supply cord cable under center silver colored terminal block screw Tighten screw 3 Connect the other wires to outer terminal block screws Tighten screws 4 Tighten strain relief screws 5 Insert tab of terminal block...

Страница 11: ...of the Dryer User Instructions Rigid metal vent For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid crushing and kinking Flexible metal vent Flexible metal vents are acceptable only if accessible for cleaning Flexible metal vent must be fully extended and supported when the dryer is in its final location Remove excess flexible metal vent to avoid ...

Страница 12: ...llation For use with dryer vent to wall vent mismatch Part Number 4396037 0 0 cm to 18 45 72 cm mismatch Part Number 4396011 18 45 72 cm to 29 73 66 cm mismatch Part Number 4396014 29 73 66 cm to 50 127 cm mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the m...

Страница 13: ...arking 4 Screw the legs into the leg holes by hand Use a wrench to finish turning the legs until the diamond marking is no longer visible 5 Place a carton corner post from dryer packaging under each of the 2 dryer back corners Stand the dryer up Slide the dryer on the corner posts until it is close to its final location Leave enough room to connect the exhaust vent Level Dryer Check the levelness ...

Страница 14: ...top screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove screws at top bottom and side of door 4 screws Holding door over towel on dryer grasp sides of outer door and gently lift to separate it from inner door Do not pry apart with putty knife Do not pu...

Страница 15: ...dust 10 Set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply is on Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed 11 When the dryer has ...

Страница 16: ...vez pas immédiatement les instructions Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et ce qui peut se produire en cas de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messag...

Страница 17: ...rte de la sécheuse Dimensions de la sécheuse La plupart des installations requièrent un espace minimum de 5 12 7 cm derrière la sécheuse pour le conduit d évacuation avec coude Voir Exigences concernant l évacuation Espacement minimum pour une installation dans un encastrement ou dans un placard On recommande les dimensions d espacement suivantes pour cette sécheuse Cette sécheuse a été testée pou...

Страница 18: ...ué par la CSA International à introduire dans une prise murale standard 14 30R Le cordon mesure 5 pi 1 52 m Veiller à ce que la prise murale se trouve à proximité de l emplacement définitif de la sécheuse Prise murale à 4 fils 14 30R Ne pas utiliser de cordon de rallonge Si on utilise un cordon d alimentation de rechange il est recommandé d utiliser le cordon d alimentation de rechange numéro de p...

Страница 19: ...es Instructions d utilisation de la sécheuse Conduit métallique rigide Pour un meilleur rendement de séchage on recommande d utiliser des conduits métalliques rigides On recommande d utiliser un conduit métallique rigide pour réduire les risques d écrasement et de déformation Conduit métallique flexible Les conduits métalliques flexibles sont acceptables seulement dans la mesure où ils sont access...

Страница 20: ...t Veuillez consulter la section Assistance ou service dans les Instructions pour l utilisateur de la sécheuse Installation au dessus de la sécheuse Pièce numéro 4396028 Installation de périscope pour l utilisation en cas de non concordance de la bouche de décharge de la sécheuse avec le clapet Pièce numéro 4396037 0 0 cm à 18 45 72 cm de décalage Pièce numéro 4396011 18 45 72 cm à 29 73 66 cm de d...

Страница 21: ...conduit d évacuation jusqu à l emplacement de la sécheuse Utiliser l itinéraire le plus rectiligne possible Voir Déterminer l itinéraire d acheminement du conduit dans Planification du système d évacuation Éviter les changements de direction à 90º Utiliser des brides de serrage pour sceller tous les joints Ne pas utiliser de ruban adhésif pour conduit des vis ou autres dispositifs de fixation qui ...

Страница 22: ...te sur le dessus de la sécheuse Ôter les vis supérieures de la caisse 4 Utiliser un petit tournevis à lame plate pour ôter soigneusement quatre bouchons d obturation D du côté gauche de la caisse Insérer les bouchons dans les trous de charnières du côté droit de la caisse 5 Insérer les vis dans les trous inférieurs du côté gauche de la caisse Serrer les vis à moitié Placer la porte de telle sorte ...

Страница 23: ...ssurer d avoir tout l outillage nécessaire 3 Jeter ou recycler tout le matériel d emballage 4 Vérifier l emplacement définitif de la sécheuse S assurer que le conduit d évacuation n est pas écrasé ou déformé 5 Vérifier que la sécheuse est de niveau Voir Mise à niveau de la sécheuse 6 Brancher sur une prise à 4 alvéoles reliée à la terre Mettre le courant 7 Retirer la pellicule de protection bleue ...

Страница 24: ...d Tous droits réservés TM DURASAFE is a trademark of Whirlpool U S A Whirlpool Canada LP Licensee in Canada TM DURASAFE est une marque de commerce de Whirlpool U S A Emploi licencié par Whirlpool Canada LP au Canada 8 07 Printed in U S A Imprimé aux É U ...

Отзывы: