PAGE 6

If the resistance reading goes from infinity

to a few ohms as pulley arm closes the

switch, belt switch is OK. If not, replace the

belt switch.
If belt switch is OK and there is still an open

circuit, check and repair the wiring harness.

9.

Door Switch problems can be uncovered by

following procedure under DIAGNOSTIC: Door

Switch, page 1; however, if this was not done,

the following can be done without applying

power to the dryer. Connect an ohmmeter

across P8-3 (neutral, white wire) and P8-4

(door, tan wire).

With the door properly closed, the ohmmeter

should indicate a closed circuit (0–2

).

If not, replace the door switch assembly.

TEST #4

Heater

This test is performed when either of the following

situations occur:

Dryer does not heat
Heat will not shut off

This test checks the components making up the

heating circuit. The following items are part of this

system:

Part of Heating System

Electric

Dryer

Gas

Dryer

Harness/connection
Heater relay
Thermal cut-off
Thermal fuse

no

Inlet thermistor/high limit thermostat

assembly

no

High limit thermostat

no

Heat element assembly

no

Gas burner assembly

no

Centrifugal switch
Outlet thermistor
Machine control electronics.

See ESD information, page 1.
Console electronics and housing

assembly
Gas supply

no

Dryer does not heat:

Locate the components using figure 11.

ELECTRIC DRYER:

1.

Unplug dryer or disconnect power.

2.

Remove the toe panel to access the thermal

components. See Removing the Toe Panel,

page 9.

3.

Using an ohmmeter and referring to the wiring

diagram, measure the resistance from the red

wire terminal at the thermal cut-off to the red

wire terminal at the heater.

If the resistance is about 10

, go to step 5.

If an open circuit is detected, go to step 4.

4.

Visually check the wire connections to the

thermal cut-off, high limit thermostat, and

heater. If connections look good, check for

continuity across each of these components.

Replace the heater if it is electrically open.
Replace both the thermal cut-off and inlet

thermistor/high limit thermostat assembly

if either the thermal cut-off or the high limit

thermostat is electrically open.

5.

If no open circuit is detected, remove the 

P4 connector, then measure the resistance

between P4-3 (red wire) and P4-6 (red wire) 

at the connector. See figure 17, page 10, for

connector location; and Accessing & Removing

the Electronic Assemblies, page 9.

If 5–15 k

are measured, replace the

machine control electronics.
If the resistance is less than 1 k

, replace

the outlet thermistor.

GAS DRYER:

1.

Unplug dryer or disconnect power.

2.

Remove the toe panel to access the thermal

components. See Removing the Toe Panel,

page 9.

3.

Perform TEST #4b, page 7. If the thermal fuse

is OK, go to step 4.

4.

Perform TEST #4c, page 7. If the thermal

cut-off is OK, go to step 5.

5.

Locate the high limit thermostat. See figure 11.

Measure the continuity through it by

connecting the meter probes on the red wire

and black wire terminals.

If there is an open circuit, replace the high

limit thermostat and the thermal cut-off.
Otherwise, go to step 6.

6.

Perform TEST #4d, page 8. If this is OK,

replace the machine control electronics.

Heat will not shut off:

1.

Unplug dryer or disconnect power.

2.

Access the machine control electronics. See

figure 17, page 10, for connector location;

and Accessing & Removing the Electronic

Assemblies, page 9.

ELECTRIC DRYER:

Remove the P4 connector,

then measure the resistance between P4-3

(red wire) and P4-6 (red wire) at the connector.

GAS DRYER:

Remove the P14 connector, 

then measure the resistance between P14-3

(red-white wire) and P14-6 (red-white wire) 

at the connector.

ALL DRYERS:

If 5–15 k

are measured, replace the

machine control electronics.
If the resistance is greater than 20 k

,

replace the outlet thermistor.

Figure 11.

Thermal Components, viewed

from front.

Lt. Blue

Wires

Belt Switch

Belt Switch

Pulley

1

5

3

4

6

2

Figure 10.

Checking the belt switch.

Содержание Maytag NED7500VM0

Страница 1: ... off then stay on with displayed Continue with diagnostics 4 If entry into Diagnostic Test Mode is unsuccessful choose a different button except Stop and Cycle Signal and repeat step 2 If no indicators come on after repeating step 2 using a different button go to TEST 1 page 4 DIAGNOSTIC Active Fault Codes If there is an active fault code it will be flashing in the display Review the Display Fault...

Страница 2: ... to indicate the air flow range corresponding to the number displayed The More Dry LED will be illuminated for air flow readings above 40 cfm The Normal LED will be illuminated for air flow readings between 29 and 40 cfm The Less Dry LED will be illuminated for air flow readings less than 29 cfm If air flow value is low Less Dry LED is lit check to make sure the lint screen is clean the door seal ...

Страница 3: ... ONLY when in the Diagnostic Test Mode See TEST 4a page 7 Motor Drive System Failure F 26 flashes if there is a motor drive system failure See TEST 3 page 5 Moisture Sensor Open F 28 flashes if the moisture sensor strip is open This fault code appears ONLY when in the Diagnostic Test Mode See TEST 5 page 8 Moisture Sensor Shorted F 29 flashes if the moisture sensor strip has shorted This fault cod...

Страница 4: ...IAGNOSTIC Console Buttons and Indicators page 1 to verify repair 13 If indicators still do not light perform TEST 2 page 5 GAS DRYER 1 Unplug dryer or disconnect power 2 Remove the cover plate from the top right corner of the back of the dryer See figure 3 3 Check that the power cord is firmly connected to the dryer s wire harness See figure 5 4 Access the machine control electronics without disco...

Страница 5: ...n Thermal fuse no Belt belt switch Drive motor Centrifugal switch Door switch Machine control electronics See ESD information page 1 1 Unplug dryer or disconnect power 2 Access the machine control electronics and measure the resistance across P8 4 and P9 1 See Accessing Removing the Electronic Assemblies page 9 If resistance across P8 4 and P9 1 is in the range of 1 to 6 Ω replace the machine cont...

Страница 6: ... cut off high limit thermostat and heater If connections look good check for continuity across each of these components Replace the heater if it is electrically open Replace both the thermal cut off and inlet thermistor high limit thermostat assembly if either the thermal cut off or the high limit thermostat is electrically open 5 If no open circuit is detected remove the P4 connector then measure...

Страница 7: ...rature using an inlet thermistor that is part of the high limit thermostat assembly 1 Activate the Diagnostic Test Mode See procedure on page 1 2 If or is a displayed error in the Diagnostic Test Mode the inlet thermistor or wire harness is either open or shorted Unplug dryer or disconnect power Check wire connections at the machine control electronics and inlet thermistor See Accessing Removing t...

Страница 8: ...rness If a small resistance is not measured continue with step 8 8 Measure the resistance across each of the outermost contacts and the center terminal ground connection If a resistance less than infinity is measured replace the sensor harness 9 If moisture sensor diagnostic test passes check the thermistor Perform TEST 4a page 7 If the problem persists after replacing the moisture sensor and ther...

Страница 9: ... number appears in the display If any of the preceding conditions are not met 1 Unplug dryer or disconnect power 2 Check that the wires between the door switch and machine control electronics are connected See figure 13 for switch location and see Accessing Removing the Electronic Assemblies at right If the connections are OK replace the wire and door switch assembly and retest If wire and door sw...

Страница 10: ...r Accessing Removing the Electronic Assemblies page 9 and disconnect the P2 and P5 harnesses from the machine control 4 The console mounting bracket is fastened to the console front panel with two latches at both sides of the console assembly Unlatch the bracket gently with a screwdriver while pulling the mounting bracket assembly out See figure 18 5 The console electronics is split into two assem...

Страница 11: ...9828 6020698 6047486 6199300 6446357 6597144 6604298 6685241 6732447 6784673 6819255 D314261 D314262 D457991 D457992 D495453 REMOVING THE BACK PANEL 1 Unplug dryer or disconnect power 2 Remove the two rear screws from the top panel and slide the top panel to the rear to remove 3 Remove the cover plate disconnect the power cord and remove ground screw 4 Remove the metal spring clip between the back...

Страница 12: ... 196 F 91 C 4M DRIVE MOTOR 1 3 H P MAIN 3 3 3 6 START 2 7 3 0 SENSOR DOOR NEUTRAL MOTOR MTR CS MOIST MOIST RTN MODEL MODEL RTN OUTLET TEMP OUTLET TEMP RTN MACHINE CONTROL ELECTRONICS Y R P13 1 P13 2 P4 4 P4 5 P4 3 P4 6 R OUTLET THERMISTOR 10 k P9 2 L1 BR L1 LINE BK HEATER V HEATER RTN N O COM BK BK BK R R W NC HIGH LIMIT THERMOSTAT 295 F 146 C THERMAL CUT OFF 352 F 178 C HEATER 7 8 11 8 DRUM LAMP ...

Отзывы: