Diagnostic Routine
ATR helps the Service Engineer to sort out the exact failure in the product
To invoke the
Auto Diagnostic Test Routine
the following sequence to be followed
Step -> 1
Keep pressing the
Program key + Water Level
Key twice,
With PCB in Off condition
Step -> 2
“ 8:88 “ will be displayed in the 7 segment & all the
LEDs will be turned ON in sequence & then to A00
To invoke ATR
Pre-Condition:
Water should be connected at both the inlet valves.
Input voltage should be nominal as per requirement.
Drain Hose should be placed as per requirement.