5.
To convert the gas distribution valve
for use with L.P. gas:
a) Pull the plastic cap off the conversion
cap.
b) Unscrew the conversion cap from the
gas distribution valve and remove it and
the plastic cap. Note the difference be-
tween the L.P. and Natural gas ends of
the cap.
c) Install the loop on the plastic cap over
the natural gas side of the conversion
cap.
d) Install the plastic cap and the conver-
sion cap on the gas distribution valve
with the L.P. side facing up (you will see
“LP” stamped inside the cap, as shown
below).
6.
Reinstall the distribution valve access
cover and storage/warming drawer on the
range.
7.
Turn the gas supply valve handle on.
Plastic Cap
Conversion Cap Set For
Use With L.P. Gas
Plastic Cap
L.P. Gas
Gas Valve Handle
To “On” Position
Conversion Cap Set For
Use With (N) Natural Gas
Natural Gas