13
Superheat = Suction Line Temperature - Saturated Suction
Temperature
Subcooling = Saturated Line Temperature - Liquid Line
Temperature
ELECTRICAL ADJUSTMENTS
This series of electric cooling and heat pump package equipment
is designed to accept a field-installed electric heat kit. The unit is
equipped to easily install the HKR Series Electric Heat Kit. Full
installation instructions are included in this kit. Please use this
document for guidance in field equipping the package unit with
electric heat.
Choose the heat kit that fits the application for the specific
installation. Permanently mark the unit’s nameplate with the
model being installed. High and low voltage connections are
detailed in the heat kit instructions.
Indoor blower motor speed tap selection may need to be
modified to accommodate normal continuous operation to
prevent a nuisance trip. See the following charts.
(F)—Factory setting
■
Speed Taps Description: H/4, 5—High; M/2, 3—Medium;
L/1—Low
■
3-Speed (H)igh/(M)edium/(L)ow: PSC motor
■
4-speed (H)igh/(ML) Medium Low/(MH) Medium High/(L)ow:
PSC motor
■
1/2/3/4/5: X-13 motor
Saturated Suction Pressure Temperature
Suction Pressure
Saturated Suction Temperature ºF
PSIG
R-410A
50
1
52
3
54
4
56
6
58
7
60
8
62
10
64
11
66
13
68
14
70
15
72
16
74
17
76
19
78
20
80
21
Saturated Liquid Pressure Temperature
Liquid Pressure
Saturated Liquid Temperature ºF
PSIG
R-410A
200
70
210
73
220
76
225
78
235
80
245
83
255
85
265
88
275
90
285
92
295
95
305
97
325
101
355
108
375
112
405
118
Electric Heat KW
Unit Model Number
5
8
10
15
20
WPH4324AM
M
(F)
M
(F)
M
(F)
H
NA
WPH4330AM
M
(F)
M
(F)
M
(F)
H
NA
WPC/WPH4336AM
3
3
H
(F)
H
(F)
NA
WPH4342AM
3
3
H
(F)
H
(F)
NA
WPC/WPH4348AM
3
(F)
3
(F)
3
(F)
3
(F)
3
(F)
WPC/WPH4360AM
3
(F)
3
(F)
3
(F)
3
(F)
3
(F)