Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: 
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.

Electrical Connection

To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Range must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
label. The model/serial number rating label is located on the 
bottom right front of the toe kick plate. Refer to the figures in 
the “Product Dimensions” section of the “Location 
Requirements” section.

This range is manufactured with the neutral terminal 
connected to the cabinet. Use a 3-wire, UL listed, 40- or 
50-amp power supply cord (pigtail) (see following Range 
Rating chart). If local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.

*The NEC calculated load is less than the total connected load 

listed on the model/serial number rating label.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with 

kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1

³⁄₈

" (34.9 mm) diameter connection opening.

A circuit breaker is recommended.

The range can be connected directly to the circuit breaker box 
(or fused disconnect) through flexible or nonmetallic sheathed, 
copper or aluminum cable. See “Electrical Connection.”

Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.

A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).

Wire sizes and connections must conform with the rating of 
the range.

The wiring diagram is located on the back of the range or 
inside the storage drawer in a clear plastic bag.

If connecting to a 4-wire system:

This range is manufactured with the ground connected to the 
neutral by a link. The ground must be revised so the green ground 
wire of the 4-wire power supply cord is connected to the cabinet. 
See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50P plug on the 
supply end. 

The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long.

The minimum conductor sized for the copper 4-wire power 
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding

If connecting to a 3-wire system:

Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.

Range Rating*

Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection

120/240 Volts

120/208 Volts

Amps

8.8 - 16.5 KW
16.6 - 22.5 KW

7.8 - 12.5 KW
12.6 - 18.5 KW

40 or 50**
50

4-wire receptacle (14-50R)

3-wire receptacle (10-50R)

Содержание Gold GGE350LW

Страница 1: ...s and Parts 3 Location Requirements 3 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Adjust Leveling Legs 6 Install Anti Tip Bracket 7 Electrical Connection 8 Verify Anti Tip Bracket Location 13 Level Range 14 Complete Installation 14 Moving the Range 15 IMPORTANT Save for local electrical inspector s use W10270322A ...

Страница 2: ...in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING WARNING Tip Over Hazard A child or adult can tip t...

Страница 3: ...storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip ...

Страница 4: ...heet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 46 119 9 cm B Model serial number rating label located on bottom right front of the toe kick plate C 35 91 4 cm D 29 75 9 cm E 26 27 66 8 69 2 cm A E D C B A 13 33 cm upper cabinet depth B 30...

Страница 5: ...through flexible or nonmetallic sheathed copper or aluminum cable See Electrical Connection Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range...

Страница 6: ...osition NOTE To place range back up into a standing position put a sheet of cardboard or hardboard in front of range Using 2 or more people stand range back up onto the cardboard or hardboard 2 Adjust the leveling legs to the correct height Leveling legs can be loosened to add up to a maximum of 1 2 5 cm A minimum of 5 0 mm is needed to engage the anti tip bracket NOTE If height adjustment is made...

Страница 7: ...r the left side or right side of the cutout Position mounting bracket in cutout so that right or left edge of the bracket is 2 4 cm from the marked edge of the range as shown 4 Drill two 3 0 mm holes that correspond to the bracket holes of the determined mounting method See the following Floor Mounting Wall Mounting 5 Using the Phillips screwdriver mount anti tip bracket to the wall or floor with ...

Страница 8: ...cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or ele...

Страница 9: ...isted conduit connector in the opening Feed the flexible conduit through the strain relief allowing enough slack to easily attach wiring to the terminal block Tighten strain relief screw against the flexible conduit 5 Replace back panel and screws on rear of range 6 Complete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not availa...

Страница 10: ...res to the outer terminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover If your home has And you will be connecting t...

Страница 11: ...ted directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires Strip the insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical...

Страница 12: ... screw The ground wire must be attached first and must not contact any other terminal 6 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 7 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 8 Securely tighten hex nuts 9 Replace terminal block access cover A Terminal block B Ground link scr...

Страница 13: ...f the 10 32 hex nuts 4 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 5 Securely tighten hex nuts 6 Replace terminal block access cover Verify Anti Tip Bracket Location 1 Make sure the anti tip bracket is installed Look for the anti tip bracket securely attached to floor or wall 2 If not direct wired plug power cord into appropriate outlet 3 Slide r...

Страница 14: ... your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material Dry thoroughly with a soft cloth For more information read the Range Care section of the Use and Care Guide 6 Read the range Use and Care Guide 7 Turn power on Turn on surface bur...

Страница 15: ...t wired ranges 1 Disconnect power 2 Slide range forward 3 Complete cleaning or maintenance 4 To check that anti tip bracket is installed use a flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under anti tip bracket 5 Check that range is level 6 Reconnect power WARNING Tip Over Hazard A chi...

Страница 16: ...W10270322A 2009 Whirlpool Corporation All rights reserved 5 09 Printed in U S A ...

Отзывы: