INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Parts supplied

Check that all parts are included.

3 - 10–32 hex nuts (attached to terminal block)

3 - Terminal lugs

Oven racks

2 - #12 x 1

⁵⁄₈

" screws (for mounting anti-tip bracket)

Anti-tip bracket (taped inside upper oven with literature 
package)

Anti-tip bracket must be securely mounted to back wall or 
floor. Thickness of floor may require longer screws to anchor 
bracket to subfloor. Longer screws are available from your 
local hardware store.

Parts needed

If using a power supply cord:

A UL listed power supply cord kit marked for use with ranges. 
The cord should be rated at 250 volts minimum, 40 amps or 
50 amps that is marked for use with nominal 1

³⁄₈

" (3.5 cm) 

diameter connection opening and must end in ring terminals 
or open-end spade terminals with upturned ends.

A UL listed strain relief.

Check local codes. Check existing electrical supply. See 
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial number rating label. 
The model/serial number rating label is located on the bottom 
right front of the toe kick plate.

The range should be located for convenient use in the kitchen.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip 
Bracket” section.

Grounded electrical supply is required. See “Electrical 
Requirements” section.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This range 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280). When such standard is not 
applicable, the Standard for Manufactured Home Installations, 
ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be 
secured to the floor during transit. Any method of securing the 
range is adequate as long as it conforms to the standards 
listed above.

Four-wire power supply cord or cable must be used in a 
mobile home installation. The appliance wiring will need to be 
revised. See “Electrical Connection” section.

Tape measure

Level

Phillips screwdriver

Flat-blade screwdriver

Wrench or pliers

³⁄₈

" nut driver

Hand or electric drill

¹⁄₈

" (3.2 mm) drill bit

Содержание Gold GGE350LW

Страница 1: ...s and Parts 3 Location Requirements 3 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Adjust Leveling Legs 6 Install Anti Tip Bracket 7 Electrical Connection 8 Verify Anti Tip Bracket Location 13 Level Range 14 Complete Installation 14 Moving the Range 15 IMPORTANT Save for local electrical inspector s use W10270322A ...

Страница 2: ...in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING WARNING Tip Over Hazard A child or adult can tip t...

Страница 3: ...storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip ...

Страница 4: ...heet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 46 119 9 cm B Model serial number rating label located on bottom right front of the toe kick plate C 35 91 4 cm D 29 75 9 cm E 26 27 66 8 69 2 cm A E D C B A 13 33 cm upper cabinet depth B 30...

Страница 5: ...through flexible or nonmetallic sheathed copper or aluminum cable See Electrical Connection Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range...

Страница 6: ...osition NOTE To place range back up into a standing position put a sheet of cardboard or hardboard in front of range Using 2 or more people stand range back up onto the cardboard or hardboard 2 Adjust the leveling legs to the correct height Leveling legs can be loosened to add up to a maximum of 1 2 5 cm A minimum of 5 0 mm is needed to engage the anti tip bracket NOTE If height adjustment is made...

Страница 7: ...r the left side or right side of the cutout Position mounting bracket in cutout so that right or left edge of the bracket is 2 4 cm from the marked edge of the range as shown 4 Drill two 3 0 mm holes that correspond to the bracket holes of the determined mounting method See the following Floor Mounting Wall Mounting 5 Using the Phillips screwdriver mount anti tip bracket to the wall or floor with ...

Страница 8: ...cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or ele...

Страница 9: ...isted conduit connector in the opening Feed the flexible conduit through the strain relief allowing enough slack to easily attach wiring to the terminal block Tighten strain relief screw against the flexible conduit 5 Replace back panel and screws on rear of range 6 Complete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not availa...

Страница 10: ...res to the outer terminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover If your home has And you will be connecting t...

Страница 11: ...ted directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires Strip the insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical...

Страница 12: ... screw The ground wire must be attached first and must not contact any other terminal 6 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 7 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 8 Securely tighten hex nuts 9 Replace terminal block access cover A Terminal block B Ground link scr...

Страница 13: ...f the 10 32 hex nuts 4 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 5 Securely tighten hex nuts 6 Replace terminal block access cover Verify Anti Tip Bracket Location 1 Make sure the anti tip bracket is installed Look for the anti tip bracket securely attached to floor or wall 2 If not direct wired plug power cord into appropriate outlet 3 Slide r...

Страница 14: ... your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material Dry thoroughly with a soft cloth For more information read the Range Care section of the Use and Care Guide 6 Read the range Use and Care Guide 7 Turn power on Turn on surface bur...

Страница 15: ...t wired ranges 1 Disconnect power 2 Slide range forward 3 Complete cleaning or maintenance 4 To check that anti tip bracket is installed use a flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under anti tip bracket 5 Check that range is level 6 Reconnect power WARNING Tip Over Hazard A chi...

Страница 16: ...W10270322A 2009 Whirlpool Corporation All rights reserved 5 09 Printed in U S A ...

Отзывы: