INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed

Parts supplied

Gas pressure regulator

Burner grates

Burner heads and caps

Clamp brackets (2)

2

¹⁄₂

" (6.4 cm) clamping screws (2)

Foam tape seal

Parts needed

Check local codes and consult gas supplier. Check existing gas 
supply and electrical supply. See “Electrical Requirements” and 
“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the underside of the 
cooktop burner box.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

The cooktop should be installed in a location away from 
strong draft areas, such as windows, doors and strong 
heating vents or fans.

All openings in the wall or floor where cooktop is to be 
installed must be sealed.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical 
Requirements” section. Proper gas supply connection must 
be available. See “Gas Supply Requirements” section.

WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.

Clear the room, building, or area of all occupants.

In the State of Massachusetts, the following installation instructions apply:

■  

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by 

the State of Massachusetts.

■  

If using a ball valve, it shall be a T-handle type.

■  

A flexible gas connector, when used, must not exceed 3 feet.

Tape measure

Flat-blade screwdriver

¹⁵⁄₁₆

" combination wrench

Pipe wrench

Channel lock pliers

Marker or pencil

Pipe-joint compound 
resistant to LP gas

Noncorrosive leak-detection 
solution

Содержание GLS3064RS0

Страница 1: ...Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation pour référence ultérieure 9761893 You can be killed or seri...

Страница 2: ... opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal i...

Страница 3: ...binet has a drawer a 4 10 2 cm depth clearance from the countertop to the top of the drawer or other obstruction in base cabinet is required The drawer depth may need to be shortened to avoid interfering with the regulator If installing a hood above the cooktop follow the hood instructions for dimensional clearances above the cooktop surface A 30 76 2 cm B 20 51 1 cm C 2 7 2 cm A 36 91 4 cm B 20 5...

Страница 4: ... In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition Type of Gas Natural Gas This cooktop is listed by Underwriters Laboratories UL cUL for use with Natural gas or after proper conversion for use with LP gas This cooktop is factory set for use with Natural gas To convert to LP gas s...

Страница 5: ...llows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the cooktop Gas Pressure Regulator The gas pressure regulator supplied with this cooktop must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP LP Gas Minimum pressure...

Страница 6: ...p into the countertop cutout by tilting one end of the cooktop into the cutout then lowering the other end into the cutout 4 Assemble hold down screws to hold down bracket See illustration below 5 Center the cooktop in the opening and using a wood block between the screw and the countertop tighten the screws moderately to secure cooktop IMPORTANT Do not tighten screws directly against the countert...

Страница 7: ...y positioned surface burners may not light and continuous sparking may occur Place burner grates over burners and caps CompleteInstallation Electronic Ignition System Check Operation of Surface Burners 1 Push in and turn the surface burner control knobs to the HI position The surface burner flame should light within 4 seconds The first time a surface burner is lighted it may take longer that 4 sec...

Страница 8: ...OWER SUPPLY N L1 G L1 A B RF 1 SWITCH VALVE B 18 BK 7 A LF 2 SWITCH VALVE B 18 BK 6 A 18 W 11 18 BU 18 18 BU 17 18 W 12 18 W 10 18 BU 15 18 BU 14 18 BK 4 LR 4 VALVE SWITCH B 18 BK 5 A 5 VALVE SWITCH 18 BK 4 20 OR 19 RR SPARK MODULE WIRING DIAGRAM GLS3665 COOKTOP 20 OR 22 IGNITER 2 20 OR 21 IGNITER 4 18 W 2 20 OR 19 IGNITER 1 N 3 IGNITER IGNITER 5 5 L1 N 4 L1 N 3 L1 N 2 L1 N 20 OR 20 18 W 9 18 BK 1...

Страница 9: ...essures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifient AVERTISSEMENT Pour votre sécurité les renseignements dans ce manuel doivent être observés pour réduire au minimum les risques d incendie ou d explosion ou pour éviter des dommages au produit des blessures ou un décès Ne pas entreposer ni u...

Страница 10: ...ur la cavité d installation entre les placards Ces dimensions tiennent compte des valeurs minimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l alimentation en gaz Veiller à placer les sources de gaz et d électricité selon ...

Страница 11: ...e liaison à la terre il est recommandé qu un électricien qualifié vérifie la qualité de la liaison à la terre Pour obtenir un exemplaire de la norme des codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A Détendeur fourni flèche pointée vers la table de cuisson B Prise de cou...

Страница 12: ...user une déficience du débit d alimentation On doit utiliser un composé d étanchéité des tuyauteries résistant à l action du gaz de pétrole liquéfié Ne pas utiliser de ruban TEFLON Pour l alimentation au propane le diamètre des canalisations doit être de ou plus Usuellement le fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre approprié Raccord métallique flexible Si les ...

Страница 13: ...a table de cuisson Les pièces expédiées avec la table de cuisson dépendent du modèle commandé Voir la section Outillage et pièces pour une liste complète des pièces fournies avec la table de cuisson Déterminer l emplacement final de la table de cuisson Repérer le câblage existant pour éviter de le percer ou de l endommager lors de l installation Le détendeur et le connecteur à gaz flexible en acie...

Страница 14: ... dessous 2 Fixer un raccord d adaptation sur le régulateur de pression du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux raccords d adaptation 3 Utiliser une clé mixte de et une pince multiprise pour fixer le raccord flexible sur les raccords d adaptation Veiller à ne pas déformer écraser le raccord flexible Compléter le raccordement 1 Ouvrir l...

Страница 15: ...llé disjoncteur ouvert Vérifier que chaque robinet d arrêt est ouvert Vérifier que les chapeaux et têtes de brûleur sont correctement placés sur la base du brûleur S assurer à nouveau du bon fonctionnement des brûleurs Si à ce point un brûleur ne s allume pas contacter le revendeur ou un dépanneur agréé SCHÉMAS DE CÂBLAGE MISE EN GARDE Lors des contrôles d entretien placer des étiquettes sur l ens...

Страница 16: ... Arrière gauche 1 DU ROBINET CONTACTEUR B 18 N 8 A B 18 N 7 A 18 BL 13 18 BL 11 18 BU 14 18 BL 10 18 BL 12 18 BU 16 18 BU 17 18 N 5 B 18 N 6 A B A 18 BU 18 18 N 4 2 Avant gauche CONTACTEUR DU ROBINET 3 CENTRE CONTACTEUR DU ROBINET 4 Avant droit CONTACTEUR DU ROBINET 5 Arrière droit CONTACTEUR DU ROBINET 18 N 4 18 BU 18 18 BU 17 18 BU 16 18 BU 15 18 BU 15 18 BL 9 20 OR 23 9761893 2005 Whirlpool Cor...