IMPORTANT: The water heater should be located in 
an area where leakage of the tank or connections 
will not result in damage to the area adjacent to the 
water heater or to lower floors of the structure. Due 
to the normal corrosive action of the water, the tank 
will eventually leak after an extended period of time. 
Also any external plumbing leak, including those from 
improper installation, may cause early failure of the tank 
due to corrosion if not repaired.  If the homeowner is 
uncomfortable with making the repair a qualified person 
should be contacted.  A suitable metal drain pan should 
be installed under the water heater as shown below, 
to help protect the property from damage which may 
occur from condensate formation or leaks in the piping 
connections or tank. The pan must limit the water level 
to a maximum depth of 1-3/4” and be two inches wider 
than the heater and piped to an adequate drain. NOTE: 
The pan must not restrict combustion air flow.

 

Locate the 

water heater near a suitable indoor drain. Outside drains 
are subject to freezing temperatures which can obstruct 
the drain line. The piping should be at least 3/4” ID and 
pitched for proper drainage. Under no circumstances will 
the manufacturer or seller of this water heater be held 
liable for any water damage which is caused by your 
failure to follow these instructions.

1 3/4” maximum

Pipe to

adequate

drain

At least 2” greater than the 

diameter of the water heater.

Reverse flow 
of gases

Exhaust

Fan

Figure 1
Air-moving
Devices

Back

Sides

Sides

Top

View

Top

to

ceiling

Vent

Front

24” minimum 

for service

Figure 2

Minimum Clearance

Locations

Clearances and Accessibility

NOTE: Minimum clearances from combustible materials 
are stated on the data plate adjacent to the gas control 
valve/thermostat of the water heater.
The water heater is certified for installation on a 
combustible floor.

• 

IMPORTANT: If installing over carpeting, the carpeting 
must be protected by a metal or wood panel beneath 
the water heater. The protective panel must extend 
beyond the full width and depth of the water heater by 
at least three inches (76.2mm) in any direction; or if in 
an alcove or closet installation, the entire floor must be 
covered by the panel. 

• 

Figure 2 may be used as a reference guide to locate 
the specific clearance locations. A minimum of 24 
inches of front clearance should be provided for 
inspection and service.

State of California

NOTE: The water heater must be braced, anchored, or 
strapped to avoid moving during an earthquake. 
Contact local utilities for code requirements in your area 
or call 1-877-817-6750 and request instructions.

• 

The water heater should be located in an area not 
subject to freezing temperatures. Water heaters located 
in unconditioned spaces (i.e., attics, basements, 
etc.) may require insulation of the water piping and 
drain piping to protect against freezing. The drain and 
controls must be easily accessible for operation and 
service. Maintain proper clearances as specified on the 
data plate.

• 

Do not locate the water heater near an air-moving 
device. The operation of air-moving devices such as 
exhaust fans, ventilation systems, clothes dryers, 
fireplaces, etc., can affect the proper operation of 
the water heater. Special attention must be given to 
conditions these devices may create. Flow reversal of 
flue gases may cause an increase of carbon monoxide 
inside of the dwelling.

• 

If the water heater is located in an area that is 
subjected to lint, dirt, and oil, it may be necessary 
to periodically clean the flame-trap (see External 
Inspection & Cleaning of the Flame-trap).

Содержание FLAME LOCK 315420-000

Страница 1: ...y a fire or explosion may result causing property damage personal injury or death INSTALLER AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO THE WATER HEATER OWNER RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE RETAIN THE ORIGINAL RECEIPT AS PROOF OF PURCHASE Table of Contents 2 315420 000 W10100910 December 2008 Gas Water Heater with the Flame Lock Safety System Installation Instructions a...

Страница 2: ...nder water Immediately call a qualified service technician Water heaters subjected to flood conditions or any time the gas controls main burner or pilot have been submerged in water require replacement of the entire water heater Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely flammable and can...

Страница 3: ...ou or future users of this water heater will need it for future reference Service to the Flame Lock Safety System should only be performed by a qualified person Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel IMPORTANT The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths cau...

Страница 4: ... immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been extinguished Keep combustibles such as boxes magazines clothes etc away from the water heater area Site Location Select a location near the center of the water piping system The water heater must be installed indoors and in a vertical position on a level surface D...

Страница 5: ...ustible materials are stated on the data plate adjacent to the gas control valve thermostat of the water heater The water heater is certified for installation on a combustible floor IMPORTANT If installing over carpeting the carpeting must be protected by a metal or wood panel beneath the water heater The protective panel must extend beyond the full width and depth of the water heater by at least ...

Страница 6: ...ion Bubbles will show a leak Correct any leak found Figure 3 Gas Piping Manual Gas Shut off Valve Ground Joint Union 3 minimum Check with local utility for minimum height Drip leg Gas Pressure IMPORTANT The gas supply pressure must not exceed the maximum supply pressure as stated on the water heater s data plate The minimum supply pressure is for the purpose of input adjustment Gas Pressure Testin...

Страница 7: ...detergents bleaches cleaning solvents air fresheners paint and varnish removers refrigerants and many other commercial and household products When burned vapors from these products form highly corrosive acid compounds These products should not be stored or used near the water heater or air inlet Combustion and ventilation air requirements are determined by the location of the water heater The wate...

Страница 8: ...can be drawn from outside of the enclosure One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 4 The size of each opening free area is determined by the total BTUH input of all gas utilization equipment i e water heaters furnaces clothes dryers etc and the method by which the air is provided The BTUH input can be found on the ...

Страница 9: ...r supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may require larger openings to achieve the required minimum free area Screens must not be smaller than 1 4 mesh If the free area through a particular design of louver or grille is known it should be used in calculating the specified free area...

Страница 10: ...ng water heater be sure to use the new drafthood supplied with the water heater Figure 9 Drafthood Installation Sheet Metal Screws four provided Drafthood Jacket top Install the drafthood with the four screws provided Legs Slots Slots Legs Vent Pipe Size It is important that you follow the guidelines in these instructions for sizing a vent pipe system If a transition to a larger vent size is requi...

Страница 11: ...erminate with a listed cap or other roof assembly and be installed according to their manufacturer s instructions Gas vents must be supported to prevent damage joint separation and maintain clearances to combustible materials Figures 11 and 12 IMPORTANT This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases An unused chimney flue or masonry enclosure m...

Страница 12: ...ne as shown in Figure 14 These valves reduce the point of use temperature of the water by mixing cold and hot water and are readily available for use 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be located close to the wa...

Страница 13: ...ain a check valve backflow preventer or water pressure reducing valve This will create a closed water system During the heating cycle of the water heater the water expands causing pressure inside the water heater to increase This may cause the temperature and pressure relief valve to discharge small quantities of hot water To prevent this it is recommended that a diaphragm type expansion tank suit...

Страница 14: ...50 F 121 C without distortion Must be installed to allow complete drainage of both the valve and discharge line T P Relief Valve and Pipe Insulation Some Models 1 Locate the T P Relief Valve on the water heater 2 Locate the slit running the length of the insulation 3 Spread this slit open and slip it over the T P Relief Valve See Figure 15B Apply gentle pressure to the insulation to ensure it is f...

Страница 15: ...s from the system Otherwise these bubbles will be trapped in the air handler heat exchanger coil reducing the efficiency Do not connect the water heater to any system or components previously used with non potable water heating appliances when used to supply potable water Some jurisdictions may require a backflow preventer in the incoming cold water line This may cause the temperature and pressure...

Страница 16: ...tion HVAC R authorized service provider Fresh air supply free of corrosive elements and flammable vapors Fresh air openings sized correctly with consideration given to the blocking effect of louvers and grilles Ductwork is the same cross sectional area as the openings Vent Pipe System Check for proper drafting at the water heater draft hood Refer to the Checking the Draft section of this manual fo...

Страница 17: ...t with the igniter repeat steps 4 7 Continue to hold the button for about 1 minute after the pilot is lit Release the reset button and it will pop back up Pilot should remain lit If the pilot light goes out repeat steps 3 7 1 STOP It is imperative that you read all the safety warnings before lighting the pilot 2 Remove the outer door 3 Turn the temperature dial counterclockwise to its lowest setti...

Страница 18: ... the hot water supply line to reduce the risk of scald injury Emergency Shut Down IMPORTANT Should overheating occur or the gas supply fails to shut off turn off the water heater s manual gas control valve and call a qualified person Figure 17 Match Relief Opening Drafthood Figure 18 Flame Characteristics Tips may have a yellow tint Yellow inner cones are satisfactory Correct flame soft blue Water...

Страница 19: ... any issues prior to resetting the thermal switch Contact the Product Service and Support Department for service information at 1 877 817 6750 3 Reset the thermal switch by depressing the small button in the center of the thermal switch Follow the Lighting Instructions found on the front of your water heater A high temperature limit switch or ECO Energy Cut Off in the tank is used to shut off the ...

Страница 20: ...supplies are not obstructed Build up of soot and carbon on the main burner and pilot burner Check for a soft blue flame Leaking or damaged water and gas piping Presence of flammable or corrosive materials in the installation area Presence of combustible materials near the water heater After servicing this water heater check to make sure it is working properly See Operating Your Water Heater sectio...

Страница 21: ...heck the burner to see if it is dirty or clogged The burner may be cleaned with soap and hot water Figure 24A N O T W A H S T R E B O R I A C A V M R A W U T O H T H E R I SK OF Y R U J N I D L A C S R E T T O H W A T ER I S E S A E R C N N O I A C T U N I T R O L READ ALL INSTRUCTIONS WARNING BEFORE LIGHTING Pilot Tube Manifold Tube Thermocouple Right Hand Thread Figure 22 Igniter Wire Igniter Bu...

Страница 22: ...fold Assembly Figure 25 Two Piece Wire Connector Assembly Two Piece Wire Connector Thermocouple Retainer Clip Manifold Door Other fittings not shown for clarity Pilot T ube Igniter Wire Figure 26 Thermocouple Assembly Mirror Mirror Flashlight Figure 27 Flame trap visual inspection External Inspection Cleaning of the Flame trap Although not likely to occur if debris collects on the flame trap use a...

Страница 23: ...he manifold assembly into the burner compartment making sure that the tab of the manifold tube engages in the slot of the bracket inside the combustion chamber Figure 28B 4 Inspect the door gasket and make sure there is no fiberglass insulation between the gasket and the combustion chamber 5 Replace the two screws which secure the manifold assembly door to the combustion chamber and tighten secure...

Страница 24: ...pletely filled with water before lighting and activating the water heater Follow the Lighting Instructions If additional information is required contact the Service Department at 1 877 817 6750 TEFLON is a registered trademark of E I Du Pont De Nemours and Company 5 No leaks at pilot and manifold connection 6 Manifold door screws securely tightened 7 Depress the button on the thermal switch 1 Mani...

Страница 25: ...iping dip tube must be in cold inlet 8 Advise customer DRIP FROM RELIEF VALVE 1 Excessive water pressure 2 Heater stacking 3 Closed water system 1 Use a pressure reducing valve and relief valve 2 Lower the thermostat setting 3 See Closed System Thermal Expansion THERMOSTAT FAILS TO SHUT OFF 1 Thermostat not functioning properly 2 Improper calibration 1 Replace thermostat 2 Replace thermostat COMBU...

Страница 26: ...n Instructions section of this manual for specific requirements NO Is the pilot tube damaged NO Does the flame trap show signs of discoloration and or debris Shut off the gas supply to the water heater at the manual gas shut off valve then contact Customer Service at 1 877 817 6750 YES YES YES YES YES YES YES YES YES NO Contact a local Heating Ventilation Air Conditioning Refrigeration authorized ...

Страница 27: ...ation for side T P 10 Item No Parts Description 1 DRAFTHOOD 2 REDUCER RING SOME MODELS 3 FLUE BAFFLE 4 HEAT TRAP COLD SOME MODELS 5 HEAT TRAP HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE PRESSURE RELIEF VALVE LOCATED TOP OR SIDE 9 DRAIN VALVE 10 GAS CONTROL VALVE THERMOSTAT with wire leads 11 OUTER DOOR 12 PILOT ASSEMBLY KIT Natural Gas 13 PILOT ASSEMBLY KIT L P Gas 14 BURNER Na...

Страница 28: ...y Natural Gas Low Nox Item 17 Manifold door assembly which contains the manifold tube gasket door pilot tube thermocouple two piece wire connector with retainer clip thermal switch and pilot assembly L P Gas Item 18 Contains two piece wire connector and retainer clip Item 19 Contains manifold door gasket Item 20 Contains viewport Item 21 Contains piezoelectric igniter button Item 22 Contains therm...

Страница 29: ...29 ...

Страница 30: ...30 ...

Страница 31: ...31 ...

Страница 32: ...32 ...

Отзывы: