background image

Gas Dryer

PRODUCT MODEL NUMBERS
WGD94HEX, WGD95HEX, 

WGD97HEX, WGDXXHEX

Gas supply

This dryer is equipped for use with Natural 

gas. Dryer can be converted to L.P. gas. When rigid 

pipe is used it should be 1/2" IPS. When acceptable  

to the gas supplier and local codes, 3/8" approved  

tubing may be used for lengths under 20 ft (6.1 m).  

For lengths over 20 ft (6.1 m), larger tubing should be 

used. Pipe-joint compounds resistant to the action of 

L.P. gas must be used. An individual manual shutoff 

valve must be installed within 6 ft (1.8 m) of the dryer 

in accordance with the National Fuel Gas Code ANSI 

Z223.1. 

 

Electrical

A 120-volt, 60 Hz, AC-only, 15 or 20 amp 

fused electrical supply is required. A time-delay fuse or 

circuit breaker and a separate circuit are recommended. 

 

Water

 

(Steam models only)

The dryer must be  

connected to the cold water faucet using new inlet 

hoses. Do not use old hoses. Do not overtighten.  

Damage to the coupling can result.

   

4"

(102 mm)

2½"

(64 mm)

     

4"

(102 mm)

      

4"

(102 mm)

B

A

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

Number of 

90  turns 

or elbows

Type of

vent

Box or 

Louvered 

hoods

Angled

hoods

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

1

54 ft (16.5 m) 

48 ft (14.6 m)

2

44 ft (13.4 m)

38 ft (11.6 m)

3

35 ft (10.7 m)

29 ft (8.8 m)

4

27 ft (8.2 m)

21 ft (6.4 m)

Rigid metal

Rigid metal

Rigid metal

Rigid metal

o

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10057364 

10/10

OVERALL DIMENSIONS

Dryer dimensions

Select the route that will provide the straightest and most 

direct path outdoors. Plan the installation to use the fewest 

number of elbows and turns. Use the fewest 90° turns 

possible.
Do not use vent runs longer than specified in vent length 

chart.
Determine the number of elbows you will need.

For closet installation, with a door, the minimum 

ventilation openings in the top and bottom of the 

door are required. Louvered doors with equivalent 

air ventilation openings are acceptable.

For cabinet installation, with a door, the minimum 

ventilation openings in the top are required.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

The vent system chart provides venting requirments 

that will help to achieve the best drying performance.

Vent system chart:

  

NOTE:

 Side and bottom exhaust installations have  

a 90° turn inside the dryer. To determine maximum  

exhaust length, add one 90° turn to the chart.

Cabinet, Closet and Undercounter dimensions

Gas

6

1

/

4

"

(159 mm)

29

7

/

8

"*

(759 mm)

3

1

/

2

"*

(89 mm)

5

3

/

4

"*

(146 mm)

6

1

/

8

"*

(156 mm)

14

3

/

8

"

(365 mm)

25

3

/

4

"

(654 mm)

31

1

/

8

"

(790 mm)

50

7

/

8

"

(1292 mm)

Left or 

right side 

exhaust

3

1

/

2

"

(89 mm)

10

1

/

8

"

(257 mm)

34" min.

(864 mm)

1"

(25 mm)

5"

(127 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

1"

(25 mm)

7"

(178 mm)

14"

(356 mm)

1"

(25 mm)

1"

(25 mm)

5"

(127 mm)

1"

(25 mm)

1"

(25 mm)

39" min.

(990 mm)

Gas

6

1

/

4

"

(159 mm)

29

7

/

8

"*

(759 mm)

3

1

/

2

"*

(89 mm)

5

3

/

4

"*

(146 mm)

6

1

/

8

"*

(156 mm)

14

3

/

8

"

(365 mm)

25

3

/

4

"

(654 mm)

1"

(25 mm)

5"

(127 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

76

1

/

4

"*

(1936 mm)

6"

(152 mm)

1"

(25 mm)

Отзывы: