background image

 

 

 

 

EN 

 

4

 

CHARACTERISTICS

 

Components 

Ref. Q.ty Product 

Components 

1 

Hood Body, complete with: Controls, Light, Blower, Filters 

2 

Telescopic Chimney comprising: 

2.1 1 

Upper 

Section 

2.2 1 

Lower 

Section 

9 

Reducer Flange ø 150-120 mm 

10 1 

Damper 

14.1 

Air Outlet Connection Extension 

15 

Air Outlet Connection 

 
Ref. Q.ty Installation 

Components 

7.2.1 

Upper Chimney Section Fixing Brackets 

11 6 

Wall 

Plugs 

12a 

Screws 4,2 x 44,4 

12c 

Screws 2,9 x 9,5 

 

 

 

 

 Q.ty 

Documentation 

 1 

Instruction 

Manual 

 

2.1

2.2

2

12c

12a 7.2.1 11

11

12a

1

14.1

15

9

10

 

 

Содержание BE1900

Страница 1: ...Instructions Manual Cooker Hood MODEL BE1900 ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 10 EN ...

Страница 3: ...s other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance is not inte...

Страница 4: ...Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 10 1 Damper 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 1 14 1 15 9 10 ...

Страница 5: ...EN 5 5 Dimensions 90 132 370 490 60 108 259 150 min 680 max 885 680 260 300 898 1198 Min 500mm Min 650mm ...

Страница 6: ...all as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre...

Страница 7: ...nt pipe clamps not sup plied To install a ø 120 pipe To install a ø 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 10 10 RECIRCULATION VERSION AIR OUTLET Push fit connection 15 onto the hood body outlet Insert the connection extension pieces laterally 1...

Страница 8: ...assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Lower exhaust Chimney Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall making sure that they are well seated Fix the l...

Страница 9: ...Turns the Motor on at Speed two T4 Speed Fixed When pressed briefly turns the Motor on at Speed three Flashing Pressed for 2 Seconds Activates Speed four with a timer set to 10 minutes after which it returns to the speed that was set previously Suitable to deal with the highest level of cooking fumes L Light Turns the Lighting System on and off ...

Страница 10: ...L FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Refit the metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen...

Страница 11: ......

Страница 12: ...436004863_ver2 ...

Отзывы: