WHIRLPOOL PRODUCTS DEVELOPMENT LTD. SERVICE MANUAL
Ref no: 58558791 Page 5 of 19
3. INSTALLATION REQUIREMENTS
3.1 GENERAL
1.
The oven should be placed on a flat and stable surface
2.
Place the oven away from high temperature and steam sources.
3.
Clearance of at least 5cm (2”) on each side must be provided to allow
adequate ventilation.
4.
The microwave oven must be plugged directly to a 3-prong wall receptacle
which is properly grounded.
5.
The power source must be 220V 50Hz 8A single phase.
3.2 GROUNDING INSTRUCTIONS
IMPORTANT:
DISCONNECT POWER BEFORE SERVICING, RECONNECT ALL
GROUNDING DEVICES.
All mechanical parts of this appliance capable of conducting electricity are
grounded. In the event of an electrical short circuit, grounding reduces the
risk of electric shock. This appliance is equipped with a cord having a
grounding wire with a ground plug. The plug must be plugged into an outlet
that is properly installed and grounded.
WARNING:
IMPROPER USE OF THE GROUNDING PLUG MAY RESULT IN
ELECTRICAL SHOCK.
If grounding wires, screws, straps, clips, nuts or washers used to complete a
path to ground are removed for service, they must be returned to their original
positions and properly fastened.
GROUNDING SPECIFICATION:
Leakage current:
0.5mA max.
Ground path resistance:
0.1 ohm max.