INSTALLATION REQUIREMENTS

GENERAL

The oven should be placed on a flat and stable surface

Place the oven away from high temperature and steam sources.

Clearance of at least 5cm (2”) on each side must be provided to allow adequate ventilation.

The microwave oven must be plugged directly to a 3-prong wall receptacle which is properly grounded.

The power source must be 220V 50Hz  8A single phase.

GROUNDING INSTRUCTIONS

IMPORTANT:
DISCONNECT POWER BEFORE SERVICING, RECONNECT ALL GROUNDING DEVICES.

All mechanical parts of this appliance capable of conducting electricity are grounded.  In the event of an
electrical short circuit, grounding reduces the risk of electric shock.  This appliance is equipped with a cord
having a grounding wire with a ground plug. The plug must be plugged into an outlet that is properly installed
and grounded.

WARNING:
IMPROPER USE OF THE GROUNDING PLUG MAY RESULT IN ELECTRICAL SHOCK.

If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for
service, they must be returned to their original positions and properly fastened.

GROUNDING SPECIFICATION:

Leakage current:

0.5 mA max.

Ground path resistance:

0.1 ohm max.

OPERATIONAL DESCRIPTION

The following describe the basic operation of the appliance.  Please refer to the schematic diagram when
reading:

Food is placed inside the oven and the door is closed.  “Start” button is not pressed:

Primary and secondary interlock switches are closed. Monitor switch is open. Door switch is closed. Relay 1
and relay 2 are both open.

When the timer is set for a certain cooking time, cook power is set and the “Start” button pressed:

Relay 1 is closed.  AC power is supplied to the cavity lamp, fan motor and turntable motor.  Depending on the
power level setting, AC power is supplied to the HV transformer through relay 2 with the duty cycle
corresponding to the power level setting.  The display timer will start to count down.

When the timer counts to Zero:

Relay 1 and relay 2 will be and all AC power to the motor, lamp and HV transformer will be cut.  The control
board buzzer will give a “beep” sound to give an OFF signal.

When the door is open during cooking:

Primary and secondary interlock switch are opened. Door switch is opened. The monitor switch is closed. All
AC power will be cut.

Pure microwave cooking:

10 power level settings are available for pure microwave cooking. This can be adjusted using the power switch
on the touch foil.  Power level control is achieved by switching the magnetron ON and OFF periodically.  The
oven works on 15 second cycle and the following indicate the correct ON/OFF timing.

Содержание AVM 512

Страница 1: ... Technical data 3 Text Legend 4 8 Spare part list 9 Exploded view 10 Wiring diagram 11 Service Manual Microwave oven AVM 512 AVM 512 This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 11 11 1998 Subject to modification Document No 4812 714 12457 ...

Страница 2: ...the oven make sure that each replacement part you use conforms to the manufacturer s specifications Do not start a repair if you have any doubt as to your ability to complete it CAUTION MICROWAVE RADIATION PERSONNEL SHOULD NOT BE EXPOSED TO THE MICROWAVE ENERGY WHICH MAY RADIATE FROM THE MAGNETRON WAVEGUIDE OR ANTENNA IF THEY ARE IMPROPERLY USED OR CONNECTED ALL INPUT AND OUTPUT MICROWAVE CONNECTI...

Страница 3: ...Service 8538 512 62291 Doc No 4812 714 12457 Technical data Electrical Voltage 230 V Frequency 50 Hz Power consumption 1350 W Power Output power 850 W Microwave frequency 2450 MHz Timer Electronic 99 min 99 sec 10 level microwave power level 4 stage programmed cooking ...

Страница 4: ... mA max Ground path resistance 0 1 ohm max OPERATIONAL DESCRIPTION The following describe the basic operation of the appliance Please refer to the schematic diagram when reading Food is placed inside the oven and the door is closed Start button is not pressed Primary and secondary interlock switches are closed Monitor switch is open Door switch is closed Relay 1 and relay 2 are both open When the ...

Страница 5: ...erature of 10 12 C measure the temperature of the water before placing into the oven Start the oven for 1 min on full power only microwave check the time by your writwatch after the magnetron takes full power Ampere meter The unit should be heated up 2 3 times before the test starts Check the water temperature under stirring the water and calculate the difference to the start temperature C x 70 mu...

Страница 6: ...ure is found above 5 mW cm2 The unit has to be set out of function until the unit is repaired and finally saefty tested Service engineer should notify the Service Management immediately TROUBLE SHOOTING GUIDE CAUTION AND IMPORTANT Before disassembling the oven the oven power must be turned off Remove the power plug of the oven from the outlet and wait for at least 3 minutes When disassembling serv...

Страница 7: ...Power plug not in good connection with the socket No power supply Fuse blown Bad contact between fuse and fuse holder clip Loose door hinge door poorly adjusted interlock poorly adjusted causing fuse to be blown Short circuit within electrical circuit Lamp filament short HV transformer short all causing fuse blown Bad contact in contacts or terminals of timer switch primary and secondary interlock...

Страница 8: ...door when the door is shut To repair the door remount the door and fasten the screws on the door hinges The monitor switch is provided to monitor the operation of the primary interlock switch If the primary switch fails to operate when the door is open the monitor switch will form a short circuit across the supply and the fuse in the oven will blow Electric arc may form across the switch contacts ...

Страница 9: ... 00528 Shaft 320 0 4819 902 00683 Control panel 321 0 4819 902 00644 Display glass 332 0 4819 902 00557 Button door 404 0 4819 902 00614 Magnetron 406 0 4819 902 00695 Motor turn table 406 3 4819 902 00567 Gasket 412 0 4819 902 00556 Transformer HV 420 0 4819 902 00583 Capacitor HV 0 95UF 421 0 4819 902 00679 Filter 426 0 4819 218 38038 Diode HV 426 1 4819 902 00574 Diode double way 440 0 4819 902...

Страница 10: ...S E R V I C E 11 11 1998 Page 10 AVM 512 Whirlpool Europe Doc No 4812 714 12457 8538 512 62291 Customer Service Exploded view ...

Страница 11: ...S E R V I C E Whirlpool Europe AVM 512 11 11 1998 Page 11 Customer Service 8538 512 62291 Doc No 4812 714 12457 Wiring diagram ...

Отзывы: