Working temperature range:
Model
AMC 996
AMC 998
Functions
Cool/Heat
Cool/Heat
Cooling capacity (W)
2638 (1452~3441)
3710 (1935~3925)
Heating capacity (W)
2784 (1882~3817)
4140 (2151~4409)
Rated Voltage
220-240V~
220-240V~
Rated Frequency
50Hz
50Hz
Cooling/Heating rated current
3.17/3.48A
4.83/5.11A
Maximum input current
6.1A
6.4A
Cooling/Heating rated power
755/819W
1134/1259W
Energy efficiency ratio
3.56/3.65A
3.4/3.41A
Energy Class
A/A
A/B
Air circulation volume (m3/h)
450
550
Refrigerant and weight
R410A 1.25Kg
R410A 1.25Kg
Moisture Protection Class
IPX4
IPX4
Noise (Indoor/Outdoor) dB(A)
35/52
37/52
Climate type
T1
T1
Anti-electric shock protection
1
I
Weight (kg) Indoor unit/
Outdoor unit
11/45
11/45
Dimensions (cm)
WxHxD
Indoor unit
830x285x189
Outdoor
unit
848x540x320
Model
AMC 993
AMC 994
Functions
Cool/Heat
Cool/Heat
Cooling capacity (W)
5275
6741
Heating capacity (W)
5862
7474
Rated Voltage
220-240V~
220-240V~
Rated Frequency
50Hz
50Hz
Cooling/Heating rated current
7.98/7.36A
10.25/10.57A
Cooling/Heating rated power
1813/1673W
2357/2431W
Max. Power Input
2400
3500
Energy efficiency ratio
3.06/3.67A
3.06/3.21A
Energy Class
B/A
B/C
Air circulation volume (m3/h)
840
930
Refrigerant and weight
R410A 1.7Kg
R410A 2.35Kg
Noise (Indoor/Outdoor) dB(A)
44/55
46/55
Climate type
T1
T1
Moisture Protection Class
IPX4
IPX4
Anti-electric shock protection
1
I
Weight (kg) Indoor unit/
Outdoor unit
13/45
13/75
Dimensions (cm)
WxHxD
Indoor unit
1020x310x228
1020x310x228
Outdoor
unit
848x592x320
950x840x412
Model
AMC 990
AMC 991
AMC 992
Functions
Cool/Heat
Cool/Heat
Cool/Heat
Cooling capacity (W)
2257
2689
3664
Heating capacity (W)
2257
2843
3957
Rated voltage
220-240V~
220-240V~
220-240V~
Rated frequency
50Hz
50Hz
50Hz
Cooling/Heating rated current
2.98/2.89A
3.87/3.59A
4.79/5.17A
Cooling/Heating rated power (W)
676/654
876/814
1122/1171
Energy efficiency ratio
3.35/3.61
3.35/3.69
3.41/3.45
Energy class
A/A
A/A
A/B
Air circulation volume (m3/h)
422
422
479
Refrigerant and weight
R410A 0.95Kg
R410A 1.0Kg
R410A 1.2Kg
Noise (Indoor/Outdoor) dB(A)
33/50
33/50
37/54
Climate type
T1
T1
T1
Moisture Protection Class
IPX4
IPX4
IPX4
Anti-electric shock protection
1
1
1
Weight (kg) Indoor unit/Outdoor unit
11/25
11/30
11/40
Dimensions (cm)
WxHxD
Indoor unit
830x285x189
830x285x189
830x285x189
Outdoor unit
660x428x255
848x540x320
848x540x320
Working temperature range AMC 996, AMC 998
Inside Temp
DB/WB (°C)
Outside Temp
DB/WB (°C)
Maximum cooling
32/23
43/26
Minimum cooling
21/15
21/-
Maximum heating
27/-
24/18
Minimum heating
20/-
-10/-