032-03 - Gas kettles

14

USE AND CLEANING

WARNINGS AND HINTS FOR USER

- This manual contains all the instructions required for a
proper and safe use of our appliances.

Keep the manual in a safe place for future consultation!

- This appliance is for catering use, hence they must be
used only by trained kitchen staff.
- The appliance must always be kept under control during
use.

Warning!:

The manufacturer shall not be held

responsible for injuries or damage due to the non-
compliance with safety rules or an improper use of the
appliance by the operator. 

- Some improper operating conditions may even be
caused by an improper use of the appliance, therefore it is
important to train personnel properly.
- All the installation and maintenance operations must be
performed by fitters who are members of an official
register.
- Respect the periods required for maintenance. With this
is mind, customers are recommended to sign a service
agreement.
- In case of failures concerning the appliance, all outputs
(gas and water) must be cut off instantly.
- In case of recurrent failures contact a service technician.

INSTRUCTIONS FOR USE

- Before cooking with the appliance for the first time wash
the interior of the cooking vat thoroughly.

Warning!:

Fill the cooking vat up to a maximum

of 40 mm under the overflow border, according to the
maximum level mark, including the food to be cooked.

FILLING THE JACKET
(MODELS INDIRECT)

Warning!:

The water level in the jacket must be

checked each time before lighting. 
Warning!:

It is advisable to use softened water

to fill the jacket! 

- Open the level tap on the front of the appliance.
- Unscrew the filling cap on the safety valve unit. The latter
is on the right of the appliance surface (see figure “Size of
appliance and position of connections ”).
- Fill with softened water (the capacity of the jacket is
stated in the paragraph “Technical data”).
- When water flows out of the level tap, close it and screw
back on the safety unit cap.

USE OF THE PRESSURE KETTLE LID 

- Before switching on the appliance, close the lid firmly
and tighten the 4 clamps.
- The interior of the kettle can reach a maximum pressure
of 0.05 bar.
- When this pressure is exceeded, the pressure relief valve
on the lid will start operating. On request, the appliance is
also available with a pressure gauge to display the
pressure inside the kettle.

Warning!:

After cooking and before opening the

lid, all the pressure inside the kettle must be released
by lifting the relief valve (see also figure “Relief valve”.

SWITCH ON, START OF COOKING 
AND SWITCH OFF

- The appliance is equipped with a selector to start all
cooking operations (see figure “Cotrols”).
- Here is a list of the procedures for a safe and correct use
of the appliance.
Lighting the pilot burner:
- Open the gas cock before the appliance.
- Turn the knob from position (

) leftwards to the position

, press the knob and together press the piezoelectric

ignition button repeatedly..
- Once the pilot flame is on, keep the knob pressed for a
few seconds until the thermocouple heats up. 
Starting cooking – igniting main burner:
- Turn the knob leftwards to the position 

or until

minimum position 

to light the burner.

- Generally cooking is started by setting the knob on the
maximum heating position and once the vat has reached
cooking temperature, the knob is turned to the minimum
position to maintain the cooking temperature. 
End of cooking – turning off main burner and pilot burner:
- Turn the knob rightwards until position 

to turn off the

main burner; only the pilot flame will be lighted. Turn the
knob again until position (

) to turn off the pilot burner.

(See also figure “Controls”).

Содержание AGB 371/WP

Страница 1: ...nd maintenance 02 2006 GAS KETTLES AGB 373 WP AGB 378 WP AGB 387 WP AGB 393 WP AGB 388 WP AGB 379 WP AGB 391 WP AGB 394 WP AGB 371 WP AGB 374 WP AGB 383 WP AGB 389 WP AGB 376 WP AGB 385 WP AGB 395 WP AGB 398 WP AGB 397 WP AGB 402 WP AGB 403 WP ...

Страница 2: ...ection to waterworks 11 Gas connection procedures 11 Checking the operation of the gas system 11 Control of the gas inlet pressure 12 Control of primary air flow 12 Commissioning and testing 12 Conversion to other types of gas 12 Replacement of injectors for main burners 12 Replacement of injectors for pilot burner 12 Minimum output adjustment 12 Maintenance of the appliance 13 Possible failures a...

Страница 3: ... S Overflow T Technical data plate A Hot water connection 10 mm B Cold water connection 10 mm G Gas connection R 1 2 in conformity with ISO 7 1 T Technical data plate Dimensions AGB 373 WP AGB 378 WP AGB 371 WP AGB 374 WP AGB 379 WP AGB 376 WP AGB 387 WP AGB 393 WP AGB 388 WP AGB 391 WP AGB 383 WP AGB 389 WP AGB 385 WP AGB 394 WP ...

Страница 4: ...s kettles 4 T Technical data plate A Hot water connection 10 mm G Gas connection R 1 2 in conformity with ISO 7 1 B Cold water connection 10 mm Dimensions A AGB 395 WP AGB 398 WP AGB 397 WP AGB 402 WP AGB 403 WP ...

Страница 5: ...t B Gas output C Outlet pressure intake D Inlet pressure intake E Rated output adjustment screw F Gas inlet G Gas connection for pilot burner H Minimum output adjustment screw Pilot burner Main burner A Thermocouple B Pilot burner C Ignition plug D Injector E Tightness screw A Burner B Injector C Injector pipe A D E C B B A C ...

Страница 6: ...032 03 Gas kettles 6 Primary air regulation A Knob C OFF position D Minimum position E Maximum position F Pilot flame position Controls Relief valve only pressure kettles F C D A E Manual vapour vent ...

Страница 7: ...g in stallation and maintenance operations Warning Follow the fire prevention regulations very carefully GENERAL REMINDERS AND NOTES 2 CHARACTERISTICS OF THE APPLIANCES The instructions contained in this manual apply to our gas kettles in the II2H3 category see table on page 9 The data plate is located on the front of the appliance and on the control panel It contains all necessary reference data ...

Страница 8: ... indirect direct direct direct direct indirect indirect indirect indirect 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 10 10 10 10 10 10 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 1 2 1 2 1 2 10 10 10 10 10 10 10 10 1 2 1 2 3 4 3 4 3 4 1 2 1 2 3 4 3 4 3 4 1 2 1 2 3 4 3 4 3 4 1 2 1 2 3 4 3 4 3 4 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 800 800 1000 1150 1250...

Страница 9: ...r II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 G20 G30 G31 Minimum output setting Methane gas 2H Liquid gas 3 30 21 0 7 3 x 185R Adjustable 3 x 135 Adjustable 35 20 2 5 mbar 3 mbar 2 222 1 644 30 34 5 22 5 4 x 225 Adjustable 4 x 150 Adjustable 40 25 8 6 mbar 12 mbar 3 651 2 700 10 Open 48 26 5 4 x 280 Adjustable 4 x 185 Adjustable 40 25 5 6 mbar 8 5 mbar 5 079 3 757 10 Open 65 40 4 x ...

Страница 10: ...s LAWS TECHNICAL PRESCRIPTIONS AND DIRECTIVES When installing the appliance it is necessary to follow and comply with the following regulations current regulations on the matter any hygienic sanitary regulations concerning cooking environments municipal and or territorial building regulations and fire prevention prescriptions current accident prevention guidelines standards for the use of combusti...

Страница 11: ...N PROCEDURES The choice of the gas piping depends on the diameter required for the type of gas appliance and installation and should be performed in conformity with current regulations The gas feed plant can either be fixed or be disconnected if flexible pipes are employed they must be made from stainless material and not be affected by corrosion If sealing materials are used for connections they ...

Страница 12: ...rolling the following points progressive ignition of the burner even flames flame security check these points at both minimum and maximum output Check that the flue gas exhaust is not clogged and that they are expelled without any hindrance The test report must be completed in full and submitted to the customer who should then sign in acceptance With effect from this moment the appliance is covere...

Страница 13: ...lways necessary to eliminate the problem causing its activation only for models with indirect heating Problem and possible cause Access to components and operation The content of the vat does not heat up the safety thermostat has been activated The pilot burner is on but the main burners do not light up loss of pressure in gas supply clogged injectors on main burners The pilot burner does not ligh...

Страница 14: ...surface see figure Size of appliance and position of connections Fill with softened water the capacity of the jacket is stated in the paragraph Technical data When water flows out of the level tap close it and screw back on the safety unit cap USE OF THE PRESSURE KETTLE LID Before switching on the appliance close the lid firmly and tighten the 4 clamps The interior of the kettle can reach a maximu...

Страница 15: ...he lid open so that air can circulate inside the vat For added care after cleaning the external surfaces can be protected by applying a proprietary metal polish Be absolutely certain to shut off all utilities gas and water Air the room appropriately SPECIAL PROCEDURES IN CASE OF FAILURES If the appliance should not work properly during use turn it off immediately and close or cut off all supplies ...

Страница 16: ...IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED THIS DOCUMENTATION IS ONLY INTENDED FOR QUALIFIED TECHNICIANS WHO ARE AWARE OF THE RESPECTIVE SAFETY REGULATIONS WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Отзывы: