S E R V I C E
Whirlpool Europe
ADP 6940 WHM
19.10.2004 / Page 3
Customer Service
8542 940 01900
Doc. No: 4812 728 11564
Technical data
Spray arms, turning rhythm at alternating spray
system
Turning starts every time with the upper spray arm
Pre wash
Lower arm ~3min, Upper arm ~1min
Main wash Lower arm ~3min, Upper arm ~5min
Intermediate rinse
Lower arm ~2min, Upper arm ~2min
Final rinse Lower arm ~2min, Upper arm ~2min
Service Test program
Lower arm ~30sec, Upper arm ~30sec
Remark: When switching of the main switch or
interrupt the mains during the Test Program runs,
then the alternating of the spray arms change in
the test program to the rhythm of main wash 5/3
min.
Important: To leaf the Test program is possible by
made a break by customer (pushing the start
button for 1.5 sec.)
After finishing the test program (End LED shines
and/or Start LED goes of) must the appliance be
switched off.
If this will not be done, then the next normal wash
will be made with the frequency of the Service
Test Program ~30/30sec.
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
208
lmp/l
Spray pump
45 - 65
l/min
Drain pump
16
l/min
Pump height max.
1.1
m
Inlet valve
4
l/min
Spray arm lower
~ 33
l/min
Sprayarm upper
~ 27
l/min
Shower/ Sprayarm top
~ 8
l/min
Fan for drying:
Total
900
l/min
Primary air flow
210
l/min
Secondary air flow
780
l/min
Electrical base data
Voltage
220/ 240 V
Frequency
50
Hz
Total power
2.0 - 2.2
kW
Fuse
10
A
Spray pump motor alternating spray system
Voltage
220/ 240 V
Power consumption
125
W
HI
79
Ω
HA
60
Ω
Capacitor
4
µ
F
Drain pump motor
Voltage
220/ 240 V
Power consumption
30
W
Resistance
146
Ω
Fan for drying
Voltage
220 - 240 V
Resistance
141
Ω
Heating - 1 Element system
Voltage
220/ 240 V
Power consumption
1.87/ 2.04 kW
Resistance
24.5
Ω
Heating speed
~ 2.0
˚C/min
Temperature on surface
~ 115
˚C
Safety thermostat self reset
(Temperature of water)
~ 85
˚C
Fuse
206
˚C
Water safty options
Waterstop system
Reflex waterstop
Single electric water inlet valve
Voltage
220/ 240 V
Frequency
50/ 60
Hz
Resistance
3.76
k
Ω
Regenerating valve
Voltage
220/ 240 V
Frequency
50/ 60
Hz
Resistance
3.13
k
Ω
Mix valve for Regeneration
Spannung
220/ 240 V
Frequenz
50/60
Hz
Widerstand
2,0
k
Ω
Motor Diverter Valve
Voltage
220 - 240 V
Frequency
50/ 60
Hz
Resistance
6.5
k
Ω
Signal (2x within ~13 sec.) 5.0
V
Coil of dispenser
Voltage
220/ 240 V
Frequency
50/ 60
Hz
Resistance
1.3
k
Ω