background image

2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

0806_GB_42

- GAS PASTA COOKER

04/2008

5

· 12

Model

ADN 640

Description

Gas pasta cooker

N˚ Tank

1

Capacity

26 l

Dimensions in mm. (LxDxH)

400 x 700 x 900

N.

51BS3549

Primary air distance “A” mm

Methane gas G20

Liquid gas G30/G31

Category

Construction type

Air necessary for combustion

Nominal thermal power

Minimum thermal power

Overall thermal power (gas)

Connection pressure

Methane gas 2H

Liquid gas 3+

Gas connection values

Methane gas 2H

Liquid gas 3+

Nozzles Ø 1/100 mm

Main burner 

G20

G30/G31

(HuB = 9.45 kWh/m

3

) in m

3

/h

(HuB = 12.87 kWh/kg) in kg/h

Nominal thermal power

Minimal thermal capacity

Nominal thermal power

Minimal thermal capacity

G20

G30/G31

20 mbar

28/37 mbar

II2H3+

A

m

3

/h

kW

kW

No. of nozzles pilot burner

G20

G30/G31

22

20

ADN 640

18

9.0

3.8

0.952

0.704

230

Adjustable

150

100

Adjustable

20

Model

TABLE 1

These appliances are used for professional purposes. Installation,
repair and use must be carried out by expert personnel.

These instructions for installation are for our gas pasta cooker set up
for the category in the table 1 on pag. 5. The data plate is located
on the appliance, see diagram. Beware of inexpert handling.

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

Содержание ADN 640

Страница 1: ...0806_GB_42 GAS PASTA COOKER Instructions for installation use e maintenance ADN 640 04 2008 ...

Страница 2: ...CHARACTERISTICS 0806_GB_42 GAS PASTA COOKER 2 12 04 2008 Supplied by Date Customer Service FAX e mail ...

Страница 3: ...1 9 Operator training 8 5 1 10 Conversion and adjustment 8 5 1 11 Replacement of burner injector 8 5 1 12 Replacement of burner pilot injector 8 5 1 13 Setting reduced capacity power 9 5 2 Maintenance 9 5 3 Replacing parts 9 5 3 1 Gas cock 9 5 3 2 Thermocouple 9 5 3 3 Plug 9 5 3 4 Burner 9 6 Instructions for use 10 6 1 Safety cleaning and repair rules 10 6 2 Start up 10 6 2 1 Lighting pilot burner...

Страница 4: ...008 1 DIAGRAM ADN 640 45 310 400 400 Data plate 700 Gas 1 2 60 678 55 150 700 Data plate 545 Water load pipe Ø12 Gas 1 2 Water drainpipe 1 GC female Water drainpipe 1 GC female 45 132 45 32 143 117 128 305 408 305 87 Water load pipe Ø12 0 ...

Страница 5: ...l purposes Installation repair and use must be carried out by expert personnel These instructions for installation are for our gas pasta cooker set up for the category in the table 1 on pag 5 The data plate is located on the appliance see diagram Beware of inexpert handling 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 II2L3B...

Страница 6: ... is resi stant to thermal and mechanical stress The combustion chamber and flues are made of electrogalvanised steel sheeting 4 3 Assembly 4 3 1 Installation premises The appliance must be installed in a well ventilated room and if possible under a range hood check current regulations The appliance can be installed on its own or with other similar equipment If the appliance is to be installed near...

Страница 7: ...ppliance shall not be operated outside the above mentioned pressure ranges To adjust power with reduced capacity use the data in table 1 If you wish to further check the nominal power you may do so by using a gas meter according to the so called volumetric method A simple inspection is usually enough to check if injectors are func tioning correctly 5 1 3 Checking the input pressure Input pressure ...

Страница 8: ...r supply thus requiring a second operation check 5 1 10 Conversion and adjustment To change over form one kind of gas to another for example from methane to liquid gas or to another type of gas the use of suitable injectors for the main burner is required in accordance with the table 1 The injectors of the main burners and pilot for different types of gas marked with the relative diameter in hundr...

Страница 9: ...nition wire 5 3 1 Gas cock Loosen the fitting of the pipe pos 3 4 and 5 fig 1 of the gas and of the thermocouple pos 6 fig 1 and replace the piece pos 1 fig 1 install in reverse order After the replacement check the seal using a leack detetctor spray 5 3 2 Thermocouple Unscrew the nut pos 6 fig 1 fixing the thermocouple on the cock unscrew the screws pos 36 fig 3 and replace the piece pos 38 fig 3...

Страница 10: ...eased start again 6 2 2 Lighting the main burner and temperature adju stment To light the main burner after light the pilot burner place the knob in the maximum or minimum position so that the main burner igni tes Burner power regulation must be done between the max and min supply position of easily selectable interme diate levels To shut off the burner turn the knob to the right to position the m...

Страница 11: ... cleaning the tiles favour stainless steel corrosion Particularly for pots and multiple appliances it is not recom mended to load the cooking chamber only with food having a high salt content It is preferable to cook different food together i e fatty dishes or vegetables containing acids Avoid damaging the stainless steel surface in particular with different metals Residues from other metals help ...

Страница 12: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Отзывы: