TROUBLESHOOTING

Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.

Air conditioner will not operate

The power supply cord is unplugged. Plug into a grounded 
3 prong outlet. See “Electrical Requirements.”

The power supply cord has tripped (Reset button has 
popped out). 
Press and release RESET (listen for click; Reset 
button will latch and remain in) to resume operation.

A household fuse has blown, or a circuit breaker has 
tripped.
 Replace the fuse or reset the circuit breaker. If the 
problem continues, call an electrician. See “Electrical 
Requirements.”

The Fan control is turned to the off position. Turn the Fan 
control to an active setting.

The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

Too many appliances are being used on the same circuit. 
Unplug or relocate appliances that share the same circuit.

Time-delay fuse or circuit breaker of the wrong capacity 
is being used.
 Replace with a time-delay fuse or circuit 
breaker of the correct capacity. See “Electrical 
Requirements.”

An extension cord is being used. Do not use an extension 
cord with this or any other appliance.

You are trying to restart the air conditioner too soon after 
turning the fan off (or unplugging air conditioner). 
Wait at 
least 3 minutes after turning the Fan off before trying to 
restart the air conditioner.

Air conditioner power supply cord trips (Reset button 
pops out)

Disturbances in your electrical current can trip (Reset 
button will pop out) the power supply cord.
 Press and 
release RESET (listen for click; Reset button will latch and 
remain in) to resume operation.

An electrical overloading, overheating, pinching or aging 
can trip (Reset button will pop out) the power supply 
cord.
 After correcting the problem, press and release RESET 
(listen for click; Reset button will latch and remain in) to 
resume operation.

NOTE: A damaged power supply cord must be replaced with a 
new power supply cord obtained from the product manufacturer 
and must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The 
use of more efficient components may cause the air 
conditioner to run longer than an older model, but the total 
energy consumption will be less. Newer air conditioners do 
not emit the “blast” of cold air you may be accustomed to 
from older units, but this is not an indication of lesser cooling 
capacity or efficiency. Refer to the efficiency rating (EER) and 
capacity rating (in BTU/hr.) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room.
 Use exhaust 
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A 
higher capacity air conditioner may be required, depending 
on the size of the room being cooled.

Air conditioner cycles on and off too much, or does not 
cool

FAN control is set to Power Saver (on some models). Use 
Power Saver only when you are asleep or away from home, 
since the fan does not circulate the room air continuously. 
Use Low Cool, High Cool or Turbo Cool for your best comfort.

The air conditioner is not properly sized for your room. 
Check the cooling capabilities of your room air conditioner. 
Room air conditioners are not designed to cool multiple 
rooms. 

The filter is dirty or obstructed by debris. Clean the filter. 

The inside evaporator and outside condenser coils are 
dirty or obstructed by debris. 
See “Annual Maintenance.”

There is excessive heat or moisture (open container 
cooking, showers, etc.) in the room. 
Use a fan to exhaust 
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.

The louvers are blocked. Install the air conditioner in a 
location where the louvers are free from curtains, blinds, 
furniture, etc.

The outside temperature is below 65°F (18°C). Do not try to 
operate your air conditioner in the cooling mode when the 
outside temperature is below 65°F (18°C).

The temperature of the room you are trying to cool is 
extremely hot. 
Allow extra time for the air conditioner to cool 
off a very hot room.

Windows or doors to the outside are open. Close all 
windows and doors.

The Exhaust control is set to OPEN (on some models). Set 
the Exhaust control to CLOSED for maximum cooling.

The Thermostat control is not at a cool enough setting. 
Adjust the Thermostat control to a cooler setting by turning 
the knob clockwise. Turn Fan control to Turbo Cool.

Water drips from cabinet into your house

The air conditioner is not properly leveled. The air 
conditioner should slope slightly downward toward the 
outside. Level the air conditioner to provide a downward 
slope toward the outside to ensure proper drainage. See the 
Installation Instructions. 

NOTE: Do not drill a hole into the bottom of the metal base 
and condensate pan.

Содержание ACM122XR0

Страница 1: ...formance parts accessories or service call 1 800 253 1301 ACONDICIONADOR DE AIRE ManualdeUsoyCuidado Si tiene preguntas respecto a las características funcionamiento rendimiento partes accesorios o servicio técnico llame al 1 800 253 1301 Table of Contents Índice 2 1188054A ...

Страница 2: ...USAR SU ACONDICIONADOR DE AIRE 16 Cómo poner en marcha su acondicionador de aire 16 Cómo cambiar la dirección del aire 16 Sonidos normales 17 CUIDADO DE SU ACONDICIONADOR DE AIRE 17 Limpieza del filtro de aire 17 Limpieza del panel delantero 17 Reparación de la pintura dañada 17 Mantenimiento anual 17 SOLUCIÓN DE PROBLEMAS 17 AYUDA O SERVICIO TÉCNICO 19 Accesorios 19 AIR CONDITIONER SAFETY You can...

Страница 3: ...of air conditioner Air conditioner weighs 81 lbs 36 7 kg to 91 lbs 41 28 kg NOTE Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers Window installation Window opening measurements 26 66 cm minimum to 38 96 5 cm maximum opening width 15 39 4 cm minimum opening height IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or ...

Страница 4: ...eakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button will trip and pop out 4 Press and release RESET listen for click Reset button will latch and remain in The power supply co...

Страница 5: ... screws 5 Insert top and then bottom of right hand curtain housing in top and bottom curtain guides on air conditioner Back View Bottom View 6 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 8 x pan head screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom...

Страница 6: ...utside 3 Pull left hand curtain out until it fits into the window channel Repeat with right hand curtain Front View 4 Insert one of the 8 x round head screws through left hand curtain and into the window channel or through alternate hole at the top of the curtain and into the window sash to fasten the curtain to the window Top View 5 Repeat for right hand curtain CompleteInstallation 1 Insert foam...

Страница 7: ...s cooling The Exhaust control set to OPEN position allows you to draw stale or smoky air from the room Open to exhaust room air to the outside Closed to circulate room air NOTE The Exhaust control will function only when the Fan is operating Fan Set the Fan control to the desired setting When the air conditioner is operating at Low Cool High Cool or Turbo Cool the fan circulates air continuously T...

Страница 8: ... for best cooling and operating efficiency Check the filter every 2 weeks to see whether it needs cleaning NOTE Do not operate the air conditioner without the filter in place 1 Turn off air conditioner 2 Using indents in top of filter door pull door down Filter door is not removable 3 Slide air filter up and out to remove from the filter door 4 Use a vacuum cleaner to clean air filter If air filte...

Страница 9: ...t of cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTU hr marked on the air conditioner The air conditioner is in a heavily occupied room or heat producing appliances are in use in the room Use exhaust vent fans while cooking or bathing and try not to use heat produ...

Страница 10: ...553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Please record your model s information Whenever you call to request service on your appliance you need to know your complete model number and serial number You can find this information on the model and serial number label See Electrical Requirements for model and serial number location Please ...

Страница 11: ...ionar la muerte o una y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan PELIGRO ADVERTENCIA a usted y a los demás Lea y obedezca siempre todos los mensajes de seguridad Todos los mensajes de seguridad irán a continuación del símbolo de advertencia de seguridad puede morir lesión INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Para reducir el riesgo de incendio choque eléctrico o l...

Страница 12: ...fe en el cable de alimentación eléctrica Método recomendado para la puesta a tierra Este acondicionador de aire debe ser puesto a tierra Este acondicionador de aire está equipado con un cable de suministro de energía provisto de un enchufe con tres terminales Para reducir a un mínimo el peligro de posibles choques eléctricos el cable debe ser enchufado en un contacto apropiado de pared de tres ter...

Страница 13: ...de energía dañado debe ser reemplazado por un nuevo cable de suministro de energía obtenido del fabricante del producto y no debe ser reparado El cable de suministro de energíano contiene piezas que pueda arreglar el usuario Todos los reclamos de desempeño y la garantía quedarán anulados si se abre el estuche resistente a alteraciones INSTRUCCIONES DE INSTALACIÓN Desempaqueelacondicionadorde aire ...

Страница 14: ...le la cortina a los orificios superior e inferior en el gabinete del acondicionador de aire NOTA Algunas cortinas pueden tener dos ranuras en cada extremo Usted podrá ver un orificio de montaje a través de la ranura correcta 8 Deslice el alojamiento de la cortina en las guías lo más lejos posible 9 Repita los pasos anteriores para la cortina izquierda Colocacióndelacondicionadorde aire Trate el ac...

Страница 15: ...cio en el soporte y en el marco de la ventana 4 Fije el soporte de seguridad de la ventana al marco de la ventana con un tornillo de cabeza redonda 8 x para asegurar la ventana en su lugar 5 Conecte a un contacto de pared de conexión a tierra de 3 terminales 6 Presione RESET Reposición sobre el cable de suministro de energía A Cortina izquierda B Canal de la ventana A Cortina izquierda B Canal de ...

Страница 16: ...tá funcionando Fan Ventilación Ponga el control de ventilación en la posición que desee Cuando el acondicionador de aire está funcionando a temperaturas Low Cool Poco fría High Cool Muy fría o Turbo Cool Máximo nivel de fría el ventilador hace circular el aire continuamente Turbo Cool para enfriamiento máximo High Cool para enfriamiento normal Low Cool para dormir cómodo Fan Only Sólo ventilación ...

Страница 17: ...o hacia abajo en la puerta del filtro Cierre la puerta del filtro Limpiezadelpaneldelantero 1 Apague el acondicionador de aire 2 Quite el filtro de aire y límpielo por separado Vea Limpieza del filtro de aire 3 Limpie el panel delantero con un paño suave y húmedo 4 Seque el panel delantero al aire completamente Reparacióndelapinturadañada Revise una o dos veces al año si hay daños en la pintura Es...

Страница 18: ...s que generan calor durante las horas más calurosas del día Podría necesitar un acondicionador de aire con más capacidad dependiendo del tamaño de la habitación que se desea enfriar El acondicionador de aire se enciende y se apaga demasiado o no enfría la habitación El control de FAN Ventilación está puesto en Power Saver Ahorro de energía en algunos modelos Utilice el modo de Ahorro de energía ún...

Страница 19: ... 2692 Por favor incluya en su correspondencia un número de teléfono en el que se le pueda localizar durante el día Por favor anote la información sobre su modelo Siempre que llame para solicitar servicio del aparato necesitará saber el número del modelo y el número de serie completos Esta información la encuentra en la placa de número del modelo y número de serie Vea la ubicación del número del mo...

Страница 20: ...1188054A 2005 All rights reserved Todos los derechos reservados 3 05 Printed in U S A Impreso en EE UU ...

Отзывы: