EN12
After unpacking the product, check for any damage during transport. In case of problems, contact the dealer or the After-Sales Service.
PREPARING THE CABINET FOR FITTING
Connection to the terminal block
For the electrical connection, use an H05RR-F cable as specified in the table below.
INSTALLATION
WARNING
-
Install a separator panel under
the hob.
-
The lower part of the product
must not be accessible after
installation.
-
In case of installation of an
undertop oven, do not interpose
the separator panel.
•
The distance between the underside of the appliance and the separator panel must respect the dimensions given in the figure.
•
In order to ensure the correct operation of the product, do not obstruct the minimum required clearance between the hob and the top of the unit (min. 5 mm).
•
If an oven is installed beneath the hob, make sure the oven is equipped with a cooling system.
•
Do not install the hob above a dishwasher or washing-machine, so that the electronic circuits do not come into contact with steam or moisture which could
damage them.
•
To remove the hob from the worktop use a screw driver (not supplied) unlocking the springs from the bottom side of the appliance.
ELECTRICAL CONNECTION
WARNING
-
Disconnect the appliance from the power supply.
-
Installation must be carried out by qualified personnel who know the current safety and
installation regulations.
-
The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the
regulations provided in this chapter.
-
The power cable must be long enough to allow the hob to be removed from the worktop.
-
Make sure the voltage specified on the dataplate located on the bottom of the appliance is the same as that of the home.
Wires
Number x size
230 V ~ +
3 X 4 mm
2
(3X2.5 mm
2
Domino)
230-240 V ~ +
3 X 4 mm
2
(Australia only)
(3X2.5 mm
2
Domino)
230 V 3 ~ +
4 x 1.5 mm
2
400 V 3N ~ +
5 x 1.5 mm
2
400 V 2N ~ +
4 x 1.5 mm
2
Important:
- Based on the wiring diagram (see figure) either keep or remove the metal
jumpers between the screws on the terminal block L1-L2 and N1-N2.
- Make sure all six screws on the terminal block are tightened after
connecting the cables.
-Example of jumper present (left) or removed (right). See the wiring diagram
for details (the jumpers can be between L1-L2 and between N1-N2).
min 5 mm
min 20 mm
min 5 mm
230-240 V ~ (Australia only)
230 V ~ (UK only)
230 V 3 ~ (Belgium only)
400 V 2N ~ (Holland only)
DOMINO
C
B
A
Содержание ACM 712 IX
Страница 1: ......
Страница 2: ......
Страница 5: ...3 1 2 3 Min 5 mm Min 10 cm Min 3 cm Max 6 cm Min 5 mm ...