manualshive.com logo in svg
background image

12

WARNING! Installation must be carried out by 
a qualified electrician who is fully aware of 
current safety and installation regulations. The 
manufacturer declines all liability for injury to 
persons or animals and for damage to property 

resulting from failure to observe the regulations 
provided in this chapter.

Electrical connections

Hob electrical connection must be made before connecting 
the appliance to the electricity supply.

Electrical connection must be carried out in compliance 
with the regulations of the local electric utility company.

Make sure that the voltage indicated on the rating plate on 
the underside of the appliance corresponds to the domestic 
power supply voltage.

Regulations require that the appliance is earthed: use 
conductors (including the earth conductor) of the 
appropriate size only.

For electrical connection, use an H05 RR-F type cable as 
specified in the table “Power supply voltage”.

Connecting to the terminal board

Connect the yellow/green earth wire to the terminal with the 

symbol

. This wire must be longer than the other wires.

1.

Remove the terminal block cover (

A

), undoing the screw 

and inserting the cover in the terminal block hinge (

B

).

2.

Strip approx. 70 mm of sheath from the power supply 
cable. 

3.

Strip approx. 10 mm of sheath from the wires. Insert the 
power supply cable into the cable clamp and connect the 
wires to the terminal board as indicated in the diagram 
next to the terminal board itself.

4.

Secure the power cable with the cable clamp.

5.

Close the cover (

C

) and screw it on the terminal block 

with the removed screw - point (1).

Each time the cooktop is connected to the mains it 
carries out an automatic check which lasts several 
seconds.

WARNING! The power supply cable must be 
long enough to allow the hob to be removed 
from the worktop and must be positioned so as 
to avoid damage or overheating caused by 
contact with the base of the hob itself. Do not 

use extension leads.

Power supply voltage

If the hob already has a power cable, follow the 
instructions given on the label attached to the cable.
Connect the appliance to the electricity supply by 
means of an all-pole disconnect switch with minimum 

contact gap of 3 mm.

INSTALLATION and ELECTRICAL CONNECTION

DOMINO

Wires

Amount x size

230V ~ + 

3 X 4 mm

2

 

(3X2.5 mm

2

 Domino)

230-240V ~ + 

3 X 4 mm

2

 (Australia only) 

(3X2.5 mm

2

 Domino)

230V 3 ~ + 

4 X 1.5 mm

2

400V 3N ~ + 

5 X 1.5 mm

2

400V 2N ~ + 

4 x 1.5 mm

2

230V

230V

230V

230V

230V

230V

230V

230V

230V

230V

230V

A

B

C

400V 3N ~

230V ~

230-240V~FOR AU ONLY

230V~FOR UK ONLY

400V 2N ~

230V 3~

ONLY FOR BELGIUM

400V 2N~

FOR NL ONLY

77X35

31902052GB.fm  Page 12  Wednesday, September 3, 2008  4:05 PM

Содержание ACM 710/NE

Страница 1: ...ed with a thermoprotector to prevent the risk of its internal circuits being damaged by high temperatures from external heat sources e g an undercounter oven If the temperature of the electronic circuits exceeds the safety threshold the thermoprotector activates automatically switching off the hob The display shows an error message see section Troubleshooting Guide When the temperature returns to ...

Страница 2: ...eath from the power supply cable 3 Strip approx 10 mm of sheath from the wires Insert the power supply cable into the cable clamp and connect the wires to the terminal board as indicated in the diagram next to the terminal board itself 4 Secure the power cable with the cable clamp 5 Close the cover C and screw it on the terminal block with the removed screw point 1 Each time the cooktop is connect...

Страница 3: ...n unit or separating panel observe the dimensions given in the figure at the side If a column unit is installed adjacent to the hob leave a distance of at least 100 mm from the edge of the hob Assembly 1 Position the clips A in the spaces provided on the hob trim fig 3 if not already positioned 2 Measure the centre point of the vertical sides of the cut out fig 1 3 Fit the brackets C in the centre...

Страница 4: ...the hob ON OFF To switch the hob on press the button for approx 2 seconds until the cooking zone displays light up To switch off press the same button until the displays switch off All the cooking zones are switched off If the hob has been in use the residual heat indicator H remains lit until the cooking zones have cooled down The hob automatically switches off if no function is selected within 1...

Страница 5: ...g time of 99 minutes 1 hour and 39 minutes for one cooking zone only Select the cooking zone to be used with the timer an illuminated dot appears to the bottom right hand side of the heat setting indicator on the display then set the desired cooking time using the buttons and of the timer function see figure above A few seconds after the button is pressed the timer begins the countdown the luminou...

Страница 6: ...ollowing table for instructions WARNING If you are unable to turn the glass ceramic hob off after using it disconnect it immediately from the power supply After sales Service Before contacting After sales Service Try to solve the problem see Troubleshooting Guide Switch the appliance off wait 30 seconds then switch it on again to see if the fault persists If after the above checks the fault persis...

Страница 7: ...t must not be treated as household waste but must be delivered to the nearest collection centre for the recycling of electrical and electronic appliances Disposal must be carried out in accordance with local environmental regulations for waste disposal For further information on the treatment recovery and recycling of this appliance contact your competent local authority the collection service for...

Отзывы: