Electrical Shock Hazard
Connect green ground wires to ground
screws.
Failure to do so can result in death or
electrical shock.
9.
To remove the power cord,
disconnect
the ribbed lead from the capacitor termi-
nal.
10.
To remove the capacitor:
a)
Use a 20,000
Ω
, 2-watt resistor and
discharge the capacitor. Touch the
resistor leads to terminals C & H and
C & F.
b) Disconnect the wires from the termi-
nals, and remove the capacitor.
Capacitor
Perform the following steps to reinstall the
capacitor and power cord:
1.
Reconnect the wires to the capacitor ter-
minals (see below) and reinstall the ca-
pacitor.
2.
Reinstall the capacitor cover with its two
screws.
3.
Mount the control housing with its three
screws.
4.
Connect the smooth power cord lead to
terminal L1 on the electronic control board.
5.
Mount the electronic control assembly to
the control housing with its mounting screw.
6.
Connect the two green ground wires to the
evaporator frame with the hex-head screws.
All White Wires
& Power Cord
Lead (Ribbed)
To These Terminals
Brown
Brown
N/C
N/C
H
C
F
F = Fan
C = Common
H = Compressor
Ribbed Power Cord Lead