3-5
REMOVING THE ELECTRONIC CONTROL ASSEMBLY &
THERMISTOR—MODELS ACQ058MM & ACQ062MM
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug air conditioner or disconnect power.
2.
Remove the air conditioner from the win-
dow.
3.
Remove the side curtains and the front
grille (see page 3-2 for the procedures).
4.
Remove the thermistor
by unclipping it
from the holder and disconnecting it from
the control board (see step 7).
5.
Remove the screw from the electronic
control box assembly.
6.
Lift the two locking arms, and pull the
assembly forward.
7.
Disconnect the wires from the electronic
control board terminals as follows:
White from L2
Gray from L1
Yellow from COMP
Black from TURBO
Blue from HIGH
Red from LOW
To Thermistor connector from P7
Locking Arms
L2 (WH) L1 (GY) COMP (YL) TURBO (BK)
P7 (Thermistor) HIGH (BU) LOW (RD)
Unclip Thermistor
Electronic Control Box Assembly Screw