16
5. NOTE: Do not remove the spring beneath the cap.
6. Turn the gas pressure regulator cap over and reinstall on
regulator so that the solid end faces out and letter “N” is
visible.
7. Replace plastic cover over gas pressure regulator cap.
To Convert Standard Surface Burners
1. Remove burner cap.
2. Using a T20 TORX
®
screwdriver, remove the burner base.
3. Apply masking tape to the end of a
7
mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out, set gas orifice
spud aside.
4. Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural gas
orifice spud.
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
5. Place LP gas orifice spuds in plastic parts bag for future use
and keep with literature package.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
TripleTier™ Flame burner (on some models). See “To Convert
TripleTier™ Flame Burners” section.
To Convert TripleTier™ Flame Burner (on some models)
1. Remove burner cap.
2. Remove the burner head using a size T20 TORX
®
screwdriver.
3. Remove the plate on the external gas orifice spud.
IMPORTANT: The TripleTier™ Flame burner has 2 gas orifice
spuds. Do not forget to change the external gas orifice spud
located under the plate.
4. Apply masking tape to the end of a
7
mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
A. Plastic cover
B. Gas pressure regulator cap with hollow end facing out
C. Gas pressure regulator cap with solid end facing out
D. Washer
E. Gas pressure regulator cap
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A. Stamped number
A
B
C
D
Side view before
Side view after
N
E
A
B
C
D
XXX
A
Burner Location
Burner Rating
Size
Right front
Left front
Right rear
Left rear
6,000 BTU
14,000 BTU
12,500 BTU
6,000 BTU
1.10 mm
1.70 mm
1.61 mm
1.10 mm
A. Burner caps
B. Burner heads
C. External gas orifice spud access plate
D. Internal gas orifice spud
A. Plate
B. External gas orfice spud
C. Internal gas orifice spud
A
B
C
D
A
B
C