5.

Remove cardboard shipping base

from under range. Remove storage
drawer. Use a 3/8" drive ratchet to lower
rear leveling legs one-half turn. Use
channel lock pliers to lower front leveling
legs one-half turn.

Before moving range across floor, check
that range is still on cardboard shipping
base to protect floor covering.

1.

Do not use oven door handle to lift

or move the range. 

2.

Remove shipping materials, tape

and protective film from range. Keep
cardboard bottom and shipping base
under range to prevent damage to floor
covering. 

WARNING

Excessive Weight Hazard

Use two or more people to move and
install range.

Failure to do so can result in back or
other injury.

WARNING

Tip Over Hazard

A child or adult can tip the range and
be killed.

Connect anti-tip bracket to rear
range foot.

Reconnect the anti-tip bracket, if the
range is moved.

Failure to follow these instructions can
result in death or serious burns to
children and adults.

cardboard
shipping base

3.

Remove oven racks and parts

package from inside oven.

rear leveling leg

front leveling leg

6.

Make sure the anti-tip bracket is

installed:

• Look for the anti-tip bracket securely

attached to floor.

• Slide range back so rear range foot

is under anti-tip bracket. Replace
storage drawer. 

anti-tip
bracket

range foot

7.

If installing the range in a mobile

home, you must secure the range to the
floor. Any method of securing the range
is adequate as long as it conforms to the
“Manufactured Home Construction and
Safety Standards.”

8.

Place rack in oven. Place level on

rack, first side to side; then front to back.
If range is not level, pull range forward
until rear leveling leg is removed from
the anti-tip bracket. Use 3/8" drive ratchet
and channel lock pliers to adjust leveling
legs up or down until range is level. Push
range back into position. Check that rear
leveling leg is engaged in anti-tip
bracket.

NOTE:

Oven must be level for

satisfactory baking conditions.

Now start...

Anti-tip bracket
installation

Contact a qualified floor covering
installer for the best procedure for
drilling mounting holes through your
type floor covering.

4.

Use the anti-tip bracket template

to install the anti-tip bracket. 

Anti-tip bracket must be anchored
securely to the sub-floor.

Depending on the thickness of your
flooring, longer screws may be
necessary to anchor the bracket to the
sub-floor. Longer screws are available
from your local hardware store.

Содержание 9758660

Страница 1: ...T Read and save these instructions 9758660 Part No 9758660 30 Freestanding Sealed Burner Gas Range with self cleaning oven WARNING Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults www whirlp...

Страница 2: ...nstallation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition installation codes It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Proper installation is your...

Страница 3: ...a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate and that the outlet is correctly polarized Do not ground to a gas pipe Check with a qualified electrician if you are not sure range is properly grounded A 120 volt 60 Hz AC only 10 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It ...

Страница 4: ...pe on longer runs may result in insufficient gas supply Usually L P gas suppliers determine the size and materials used in the system Pipe joint compounds made for use with L P gas must be used on pipe threads only Flexible metal appliance connector If local codes permit a new AGA or CSA design certified 1 2 or 3 4 I D flexible metal appliance connector is recommended for connecting range to the g...

Страница 5: ...rea recommended for installation of rigid gas pipe Flexible gas pipe and electrical outlet are recommended in either shaded area 13 33 cm max upper cabinet depth If cabinet depth is greater than 24 61 cm oven frame must extend beyond cabinet fronts by 1 2 13 mm min 30 1 8 76 5 cm opening width 30 76 2 cm min cabinet opening width 4 1 2 11 4 cm 4 1 2 11 4 cm 2 5 1 cm IMPORTANT Some cabinet and buil...

Страница 6: ...t is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket Replace storage drawer anti tip bracket range foot 7 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the Manufactured Home Construction and Safety Standards 8 Plac...

Страница 7: ...ll connections by brushing on an approved non corrosive leak detection solution Bubbles will show a leak If a leak appears shut off gas supply valve and tighten connections Then check connections again Clean all leak detection solution from gas connections Close broiler door 13 Center the burner cap on burner base Burner cap should be level when properly positioned Place burner grates over burner ...

Страница 8: ...o 350 F Check operation Electronic ignition system Cooktop and oven burners use electronic ignitors in place of standing pilots When a cooktop control knob is turned to the LIGHT position the system creates a spark to light the burner This sparking continues until the control knob is turned to the desired setting When the oven control is set to the desired setting a series of sparks lights the ove...

Страница 9: ...hould light within 8 seconds If your range has an oven temperature control knob Push in and turn the oven selector control knob to BROIL If the burner fails to light due to air remaining in the gas line reset the oven control by turning selector knob to OFF and then again to BROIL CLEAN 200 300 400 450 BROIL PUSH TO TURN OFF PUSH TO TURN WARM 250 350 500 OVEN ON TURN OFF OVEN WHEN FLASHING OVEN HE...

Страница 10: ...emaining orifice spuds one at a time Place the Natural gas spuds on the spud card on the back of the range for future use Replace burner caps using both screws and burner grates Gas conversions Gas conversions from Natural gas to L P gas or from L P gas to Natural gas must be done by a qualified installer Fire Hazard Shut off gas supply line valve Make all conversions before turning gas supply val...

Страница 11: ...ss orifice spuds in the center of each burner throat about 2 5 cm below the cooktop Apply masking tape to the end of a 5 16 nut driver to fit snugly over the orifice spud Press driver down onto the spud of the left front burner and remove by turning spud counter clockwise and lifting it out Replace the L P gas spud with the appropriate Natural gas spud shown in the table Continue to replace the re...

Страница 12: ...rlpool Corporation Benton Harbor Michigan 49022 2 2004 7 Check that range is level 8 Reconnect gas line to range and check for leaks 9 Plug in range or reconnect power 10 Reinstall storage drawer Moving the range anti tip bracket range foot If you need assistance If you have questions about operating cleaning or maintaining your range Refer to Use and Care Guide Call the Customer Interaction Cente...

Отзывы: