GB8

1.

Control panel.

2.

Grease filter (above the perimeter suction filter).

3.

Halogen bulbs.

4.

Telescopic chimney.

5.

Sensors.

6.

Perimeter suction panel.

Digital control panel with sensors

1. Motor OFF/Stand-by key
2. Speed decrease key
3. Speed increase key
4. ON/OFF light key
5. Grease filter alarm reset
6. "6th Sense" key /"Air Quality Control" (Automatic Operation)
7. Carbon filter alarm reset 
Speed 1 notification LD1
Speed 2 notification LD2
Speed 3 notification LD3
Speed 4 notification LD4
"Air Quality Control" operation mode notification LD5

1. OFF/Stand-by key  

To put the hood in 

Stand-by

press 1 for at least 2 seconds. This operation enables all keys, puts the hood in 

Stand-by

mode (hood ready for operation. Keys "

1

"

and "

6

" come on) and activates the "

6th Sense

" mode.

Press key "1" again for at least 2 seconds to switch the hood 

OFF

and disable all keys with the exception of key "

4

".

2. Speed decrease key  

3. Speed increase key  

The speed of the motor may be increased or decreased, from speed one up to intensive speed, and vice versa, by pressing keys "2" and "3" respectively.
Press and hold down keys "2" or "3" to keep increasing/decreasing the speed at one second intervals.
The current speed is shown by the bar, which will gradually extend, at set intervals, depending on the set speed, in accordance with the following:

Speed 1

LEDs "LD1" on.

Speed 2

LEDs "LD1" and "LD2" on.

Speed 3

LEDs "LD1", "LD2" and "LD3" on.

Speed 4 (intensive speed)

LEDs "LD1", "LD2" and "LD3" on, LEDs "LD4" flashing.

Note: 

speed 4 is the intensive speed and is timed.

As a standard, the hood will operate at this speed for 5 minutes, after which time speed 2 will resume.
To deactivate this function before the 5 minutes expire press "2".

4. ON/OFF light key  

Press the key to gradually switch the lights on/off varying their intensity.

USING THE HOOD

Содержание 891

Страница 1: ...maintenance operations must be carried out by a qualified technician When drilling through the wall pay attention not to damage electric connections and or pipes Air vents must always discharge to the outside The manufacturer rejects all responsibilities for any damage caused by improper use or wrong settings Appropriate maintenance and cleaning ensure the good working order and the best performan...

Страница 2: ... in an accessible place install a standardised double pole power switch that will enable complete isolation from the mains in case of category III overvoltage conditions in accordance with installation rules GENERAL RECOMMENDATIONS Before use Remove cardboard protection pieces protective film and adhesive labels from accessories Check the appliance for any transport damage During use To avoid any ...

Страница 3: ...service number number after the word Service on the rating plate located on the inside of the appliance The service number is also indicated on the guarantee booklet your full address your telephone number If any repairs are required please contact an authorised After sales Service to guarantee that original spare parts will be used and repairs carried out correctly Never use steam cleaning equipm...

Страница 4: ...dicated by the three points and with a gentle pressure lift the cover from its position 3 Remove the faulty light bulb and replace with a new one 4 Replace the cover spring lock ACTIVE CARBON FILTER filter models only The carbon filter must be washed once a month in the dishwasher at the highest possible temperature using a standard dishwasher detergent It is recommended that nothing else is place...

Страница 5: ...od steam outlet and the discharge duct fits correctly to both IMPORTANT If already installed remove the carbon filter s Filtering model The air is filtered through one of the carbon filters and then resent to the room IMPORTANT Ensure appropriate air circulation around the hood Before using the hood ensure that the carbon filter s has have been installed The hood should be installed away from part...

Страница 6: ...the hood to the wall in its final position with the 2 screws 15 Connect the cooking steam discharge tube to the fitting B The tube must be directed towards the outside suction model or towards the deflector filter model The deflector F must be fitted to the G chimney support bracket using 2 screws 16 Connect the power supply 17 Fit the chimneys in position above the hood and fully cover the suctio...

Страница 7: ...GB7 ...

Страница 8: ...st 2 seconds to switch the hood OFF and disable all keys with the exception of key 4 2 Speed decrease key 3 Speed increase key The speed of the motor may be increased or decreased from speed one up to intensive speed and vice versa by pressing keys 2 and 3 respectively Press and hold down keys 2 or 3 to keep increasing decreasing the speed at one second intervals The current speed is shown by the ...

Страница 9: ... return to Stand By mode 7 Carbon filter alarm reset key After 320 hours of operation with the hood ON the carbon filter alarm reset key comes on to indicate that the carbon filter needs cleaning Once the carbon filter has been cleaned press 7 for at least 3 seconds while the hood is ON operating at any speed to reset the filter alarm In standard mode the electronic system is set to provide notifi...

Страница 10: ... selection will be confirmed by the selection itself flashing 3 times Once the selection has been saved the hood will go off Note The type of hob set by default is the Gas hob Disconnect the appliance from the power supply Cleaning the perimeter suction panel Dismantling Pull the panel FRONT SIDE downwards Cleaning The suction panel must be cleaned with the same frequency as the grease filter Use ...