WHIRLPOOL ELECTRICAL APPLIANCES CO. LTD. SERVICE MANUAL
Ref: 54158291a
PAGE 4 OF 17
2.
SAFETY PRECAUTIONS
This manual is intended for use by personnel with adequate background in
electrical, electronic and mechanical engineering. Any improper attempt to repair
this oven may result in personal injury and property damage. The manufacturer or
seller cannot be hold responsible for the interpretation of this manual nor can they
assume any liability in connection with its use.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING
TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY.
a.
Do not operate or allow the oven to be operated when the door is opened.
b.
Make the following safety checks on all ovens to be serviced before
activating the magnetron or other microwave sources, and make repairs
when necessary:
1.
Interlock operation
2.
Proper door closing
3.
Seal and sealing surfaces (arcing, wear, and other damage)
4.
Damage to or loosening of hinges and latches
5.
Evidence of dropping or abuse
c.
Before turning on the microwave power for any service test or inspection
within the microwave generating compartments, check the magnetron, wave
guide or transmission line, and cavity for proper alignment, integrity, and
connection.
d.
Any defective or misadjusted components in the interlock, monitor, door
seal, and microwave generation and transmission system shall be repaired,
replaced, or adjusted by procedures described in this manual before the oven
is released to the owner.
e.
A microwave leakage check to verify compliance with the Federal
Performance standard should be performed on each oven prior to release to
the owner.
TO PREVENT ELECTRICAL SHOCK, PAY EXTREME CAUTION WHEN
DIAGNOSING OVEN WITH OUTER CASE REMOVED AND POWER
TURNED “ON”. THE HIGH VOLTAGE SECTION OF THE POWER
SUPPLY, INCLUDING FILAMENT LEADS, ARE AT A HIGH TENSION
OF -4000 VOLTS. ALSO, ENSURE THAT THE HIGH VOLTAGE
CAPACITOR IS DISCHARGED.