to dryer

shutoff valve
“open” position

gas supply
line

H.

If local codes and ordinances

permit, it is recommended that new
flexible metal tubing, design-certified
by the AGA or CSA, be used for
connecting the dryer to the gas
supply line. (The gas feed pipe which
extends through the lower rear of the
dryer is provided with 3/8-inch metal
pipe thread.)

I.

If rigid

pipe is used 
as a gas supply line, a
combination of pipe fittings must
be used to obtain an in-line
connection to the dryer.

J.

Make sure that lower edges of

the cabinet, plus the back and
bottom sides of the dryer are free of
obstructions to permit adequate
clearance of air openings for
combustion air. See "Recessed area
and closet installation instructions,"
page 12, for minimum spacing
requirements. 

K.

For ease of installation,

operation and servicing (if ever
needed) adequate space should be
provided around the dryer.

L.

A 1/8-inch NPT plugged tapping,

accessible for gauge testing, must be
installed immediately upstream of the
gas supply connection to the dryer. 

The dryer must be disconnected from
the gas supply piping system during
any pressure testing of the system at
test pressures in excess of 1/2 psig.

The dryer must be isolated from the gas
supply piping system by closing the
equipment shut-off valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psi.

Electrical

requirements

C.

Check that dryer is equipped

with the correct burner for the
particular type of gas used. Burner
information can be found on the
serial/rating plate in the door well of
the appliance. If this information does
not agree with the type of gas
available, see your dealer.

D.

This dryer is equipped for use

with NATURAL GAS. It is certified by
CSA International for manufactured,
mixed and L.P. (propane and
butane) gases with appropriate
conversion. No attempt shall be
made to convert the appliance from
the gas specified on the serial/rating
plate for use with a different gas
without consulting the serving gas
supplier. 

Conversion must be done by

a qualified service technician. Gas
conversion kit part numbers are listed
on the gas valve burner base.

E.

Provide a 

rigid gas supply line 

of

1/2-inch IPS pipe to the dryer
location. If the total length of the
supply line is more than 20 feet 
(6.1 m), larger pipe will be needed.
For L.P. gas usage, 3/8-inch,
approved copper tubing may be
used. Pipe-joint compounds suitable
for use with L.P. gas should be used.

F.

The supply line shall be equipped

with a shutoff valve installed within 6
ft. (1.8 m) of dryer in accordance with
the National Fuel Gas Code, ANSI
Z223.1 — latest edition*. This valve
should be located in the same room
as the dryer and should be in a
location that allows ease of opening
and closing. Do Not block access to
the shutoff valve.

G.

If the dryer is installed in a

confined area such as a bathroom or
closet, provision must be made for
enough air for combustion and
ventilation. (Check governing codes
and ordinances. or refer to the
section of this instruction covering
recessed and closet installations.)

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

A 120-volt, 60-Hz, AC-only, 15- or 
20-ampere fused electrical supply is
required. A time-delay fuse or circuit
breaker is recommended. 

It is recommended that a separate
circuit serving only this appliance be
provided.

Important: Observe all governing
codes and ordinances.

3-prong ground-type
outlet 

3-prong 
ground 
plug

power
supply cord

ground
prong

Copies of the standards listed above may
be obtained from:
*  National Fire Protection Association 

One Batterymarch Park
Quincy, Massachusetts 02269

Electrical Shock Hazard

Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or electrical
shock.

Recommended
ground method

The dryer, when installed, must be
electrically grounded in accordance
with local codes, or in the absence of
local codes, with the National
Electrical Code, ANSI/NFPA 70*.

GROUNDING INSTRUCTIONS: This
appliance must be grounded. In the
event of malfunction or breakdown,
grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current.

The power supply cord plug must be
plugged into an appropriate outlet
that is properly installed and
grounded in accordance with all
local codes and ordinances. 

WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the plug
provided with the appliance - if it will
not fit the outlet, have a proper outlet
installed by a qualified electrician.

WARNING

Содержание 8316557

Страница 1: ...tallation Instructions with the owner Owner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use COMMERCIAL ELECTRONIC DRYER GAS Part No 8316557 COMMERCIAL LAUNDRY PRODUCTS www whirlpool com 120 volt 60 Hz ELECTRIC 120 240 volt 60 Hz ...

Страница 2: ...nstalled in an area where it will be exposed to water and or weather It is your responsibility to If installing a GAS dryer FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using your appliance follow basic preca...

Страница 3: ...tal foil vent Failure to do so can result in death or fire WARNING Metal flexible vent must be fully extended and supported when the dryer is in its final position DO NOT KINK OR CRUSH THE VENT The metal flexible vent must be completely open to allow adequate exhaust air to flow Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Remove excess flex...

Страница 4: ... is required A main exhaust vent can be used for exhausting a group of dryers Main exhaust vent should be sized to remove 200 CFM of air per dryer Large capacity lint screens of proper design may be used in the main exhaust vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all the dryers in the room Back draft D...

Страница 5: ...d For L P gas usage 3 8 inch approved copper tubing may be used Pipe joint compounds suitable for use with L P gas should be used F The supply line shall be equipped with a shutoff valve installed within 6 ft 1 8 m of dryer in accordance with the National Fuel Gas Code ANSI Z223 1 latest edition This valve should be located in the same room as the dryer and should be in a location that allows ease...

Страница 6: ...evel adjust the legs of the dryer up or down until the dryer is level 12 Plug power supply cord into grounded outlet 13 Check dryer operation some accumulated time may be on the timer due to factory testing Pull timer set button left Operating time will accumulate per number of depressions and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer...

Страница 7: ...lectrical requirements If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Important Observe all governing codes and ordinances A four wire or three wire single phase 120 240 volt 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if specified on the model serial rating plate is required o...

Страница 8: ...Four wire recommended method Three wire if four wire is not available 1 Disconnect the power supply 2 Remove hold down screw and terminal block cover Power supply cord Direct wire This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of connection use Four wire connection instr...

Страница 9: ... the other wires to outer terminal block screws Tighten screws 6 Connect the ground wire bare of the power supply cable to the external ground conductor screw Tighten screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slot of the dryer re...

Страница 10: ...utral wire 4 Loosen or remove center terminal block screw 7 Tighten strain relief screws 8 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 6 Place the hooked ends of the other power supply cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws 5 Place the hooked end of the neutral wire white...

Страница 11: ... separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate 7 To exhaust dryer see Exhaust requirements Pages 3 4 Connect exhaust vent to dryer exhaust outlet and exhaust hood using 4 10 2 cm clamps Use caulking to seal exterior wall opening around exhaust hood 8 Carefully move dryer into final position Place level on top of the dryer fir...

Страница 12: ...6 cm 48 sq 24 sq The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet 14 35 6 cm max 1 2 5 cm 4 10 2 cm dia This dryer may be installed in a recessed area or closet For recessed area and closet installations minimum clearances can be found on the serial tag on the dryer The installation spacing is in inches and is minimum allowable Additional spa...

Отзывы: