5019 318 33278
Description and use of hood
1. Control panel.
2. Grease filters.
3. Halogen lamps.
4. Telescopic flue.
5. Sensors.
Digital control panel with sensors
1. Motor ON/OFF
Press the button and the hood starts at speed 1.
Press the button during operation and the hood switches
OFF.
2.
Increase speed / Speed timing
Press the button and the hood goes from OFF to speed 1.
Press the button (hood ON) to increase the motor speed
from speed 1 to intensive.
The respective LED (green) lights up at each speed.
Speed 1 LED “L1”
Speed 2 LED “L2”
Speed 3 LED “L3”
Intensive speed LED “L4” (blinking)
The Intensive speed is timed. The standard operating
time is 5 minutes, after which the hood goes to speed 2.
To deactivate the function before the time has elapsed,
press button “2”, the hood will go to speed 1; press
button 1 and the hood will switch off.
3. Light ON/OFF switch
4. Sensor ON/OFF switch
5. Operation status indicator
Speed timing
Press button “2” for 2 seconds to enable speed timing; the
hood switches off when the time has elapsed.
Operation times are as follows:
Speed 1
20 minutes (LED “L1” blinking)
Speed 2
15 minutes (LED “L2” blinking)
Speed 3
10 minutes (LED “L3” blinking)
Intensive speed
5 minutes (LED “L4” blinking)
During timed operation, press button “1” to switch off the
hood; press button “2” to return to the set speed; press
button “4” and the hood switches to “Cooking” mode.
Grease filter saturation indicator
After 80 hours of operation, LEDs “L1” and “L2” blink.
This indicates that the grease filter installed needs to be
cleaned.
To reset the indicator, keep button “1” pressed for 3 seconds”.
Carbon filter saturation indicator
After 320 hours of operation, LEDs “L2” and “L3” blink.
This indicates that the carbon filter installed needs to be
replaced.
To reset the indicator, keep button “1” pressed for 3
seconds”.
In the event both filters indicate saturation at the same time,
LEDs “L1”, “L2” and “L3” blink.
Reset by carrying out the above procedure twice.
The first time resets the grease filter indicator; the second
resets the carbon filter indicator.
The carbon filter saturation indicator is not active in the
standard mode.
If using the hood in filter version, activate the carbon filter
saturation indicator, as it is not activated automatically.
Activating the carbon filter saturation indicator:
Switch the hood OFF and keep buttons “2” and “3” pressed
at the same time for 3 seconds”.
LEDs “L1” and “L2” will blink for 2 seconds”.
Deactivating the carbon filter saturation indicator:
Switch the hood OFF and keep buttons “2” and “3” pressed
at the same time for 3 seconds”.
LED “L1” will blink for 2 seconds”.
Automatic operation
The system default setting is manual mode; press button “4”
to activate automatic mode”.
The system provides for automatic operation in 2 modes:
-
COOKING
mode, which guarantees correct extraction of
fumes during cooking.
-
AIR QUALITY CONTROL
mode, which is a monitoring
system that guarantees a high air quality level.
The 2 modes are activated cyclically by pressing button “4”.
COOKING
mode LED “L5” (amber) on.
During cooking, the system promptly reacts to Steam/Gas
increases and remains at the set speed for at least 1 minute,
before returning to the lowest speed/switching off.