Page 6-3
Steady State Current = 3.0 Amps @ 115
±
1 VAC @ 75˚F
±
10˚
Ambient.
Cold Resistance = 500
Ω
TO 1100
Ω
@ 75˚F
±
10˚ Ambient.
Maximum Operating Temperature Not To Exceed 2650˚F @
115
±
1 VAC @ 75˚F
±
10˚ Ambient.
TESTING AN OVEN GLO-BAR IGNITER
If the glo-bar ignitor (see Figure 6-2) does not glow, perform the following steps to test it:
1.
Turn off the gas and electrical power to the range.
2.
Disconnect the oven igniter quick-disconnect plug from the main harness connector.
3.
Connect an ohmmeter across the wire ends or terminals of the glo-bar. If the meter reads over
1100
Ω
, replace the igniter.