Page 4-5
OFF
N
A
T
L
P
OFF
N
A
T
L
P
Oven
Thermostat
Main Gas Line
Pilot Gas Line
Natural Gas
Setting
Adjustment
Screw
Gas “OFF”
Setting
L.P. Gas
Setting
NOTE: The thermostat used in the Standing Pilot range needs to be converted if L.P. gas is being
used. A "Nat" or “L.P.” setting is located on the front face of the thermostat (see Figure 4-8 and its
inset).
Figure 4-8
Inset
LIGHTING THE OVEN PILOT
To light the pilot, perform the following steps (see Figure 4-9):
1.
Turn off all the range controls.
2.
If your range is equipped with a broiler drawer, open it and wait five minutes for any gas inside
the range to dissipate.
3.
Remove the baffle and oven bottom.
4.
Hold a lighted match near the tip of the pilot on the burner assembly until a flame appears.
5.
Replace the baffle and oven bottom.
6.
Turn on the oven thermostat and allow the burner to light.
Figure 4-9
Safety
Valve
Apply Match Flame
To Gas Outlet Of Pilot