background image

6.

Connect the other

wires to outer terminal
block screws. Tighten
screws.

7.

Tighten strain

relief screws.

8.

Insert tab of terminal block

cover into slot of dryer rear
panel. Secure cover with
hold-down screw.

5.

Remove the appliance

ground wire (green with yellow
stripes) from the external
ground connector screw.
Connect appliance ground wire
and the neutral wire (white or
center) of the power supply
cord/cable under the center,
silver-colored terminal block
screw. Tighten screw.

9.

Connect a separate copper ground wire

from the external ground connector screw to
an adequate ground.

4.

Remove center terminal block screw.

DIRECT WIRE 

OR POWER SUPPLY CORD

Where local codes Do Not permit 

connecting cabinet-ground conductor to neutral wire:

Three-wire power supply cord 

must be

four feet long and have three, No.-10
copper wires and match a three-wire
receptacle of NEMA Type 10-30R.

Direct wire power supply cable 

must be

prepared as shown in “Preparing the wire”
of the three-wire connection direct-wire
steps above.

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Panel E

D.

Level & exhaust

the dryer

Dryer must be level to reduce noise and assure
proper performance.

Slide dryer onto cardboard or hardboard before
moving across floor to prevent floor damage.

1. 

Move dryer close to its permanent location.

Leave enough room to connect exhaust vent. Remove
cardboard or hardboard from under dryer.

2. 

Check levelness of dryer by placing a level on

top of dryer, first side to side, then front to back. If
dryer is not level, adjust dryer legs up or down.  

If legs are not long enough to level dryer, order
Extended Dryer Feet Kit, Part No. 279810 (sold two
legs per kit), from your dealer.

3.

Using a 4" clamp,
connect exhaust vent to
exhaust outlet in dryer. If connecting
to existing exhaust vent, make sure
the vent is clean. 
The dryer exhaust vent 

must

fit over the dryer

exhaust outlet and inside the exhaust hood.

Make sure exhaust vent is secured to exhaust hood
with a 4" clamp.

4. 

Move dryer into final position. Do not crush

or kink exhaust vent. Make sure dryer is level.

3. 

Read the Use and Care Guide to fully

understand your new dryer. Select a full heat cycle
(not the air cycle) and start dryer. After five minutes,
open dryer door. You should feel heat inside dryer.

If dryer does not operate properly, check the
following:

electrical supply is connected.

house fuse is intact and tight; or circuit breaker

has not tripped.

dryer door is closed.

controls are set in a running or “On” position.

start button has been pushed firmly.

If dryer makes an unusual noise, check that the dryer
is level.

E. 

Check operation

1. 

Check that you:

did not skip any steps.

installed all parts.

properly installed dryer legs.

leveled dryer.

have secured all exhaust vent joints with 4" clamps.

have all the tools you started with.

2. 

Plug power supply cord into grounded outlet

or connect direct wire to power supply. Turn power
supply on.

4" clamp

4" clamp

SURE CONNECT

TM

Vent Kit

CRUSH

RESIST

ANT

Dura Safe

TM 

Kits Make Installation Easy

Provides 4 1/2” 
clearance between 
dryer and wall

Snap-Lock fittings

Total kit length 
8 feet

Additional vent can 
be snapped between
sections for 
longer runs

Kit Contains:

2- 4' vent sections with attached close elbows
1- Wall plate for close clearance installations
2- 4" clamps

Part #4396028

Sections separate, 
fittings can face
same or opposite

Extra long
band-clamp 
for dryer 
connection

Swivel collar

Beveled edges
allow corner
installations

Telescoping 
sections

Swivel collar 
wall connection

Provides 2 1/2” clearance 
between dryer and wall

Great for closet

installations

0"-18", 18”-29” or 
29”-50” periscopes 
include one male 
snap-lock fitting, 
one extra long 
draw-band collar 
and one clamp

2

 1/2"

1

/

2

"

Periscopes For Offset

Outlets, Tight Installations

Use when vent outlets
overlap or are offset

Excess length can 
be trimmed to fit

18"-29" and 29"-50" Periscope

0"-18" Periscope

0"-18" : Part #4396037

18"-29" : Part #4396011
29"-50" : Part #4396014

Part #4396037

18"-29" : Part #4396011             29"-50" : Part #4396014

Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.

For more information, 

or to easily place your

order, call 

1-800-442-9991

To have your venting 

professionally installed,

call 

1-800-253-1301

for the nearest 

authorized service

provider.

.

Содержание 3979171

Страница 1: ... Homeowner Keep Installation Instructions for future reference For best performance install dryer according to Installation Instructions Failure to complete installation as instructed could void warranty Save Installation Instructions for local electrical inspector s use U L listed strain relief 3 wire power supply cord with ring or spade terminals and U L listed strain relief 3 wire receptacle 10...

Страница 2: ...9 A clothes dryer produces combustible lint and must be exhausted outdoors If codes permit dryer may be installed in a recessed area or closet using dimensions shown Dimensions are in inches and are the minimum allowable Additional spacing should be considered for ease of installation and servicing Companion appliance spacing should also be considered Observe all governing codes and ordinances Che...

Страница 3: ...Do not use a plastic vent Do not use a metal foil vent Failure to do so can result in death or fire WARNING Typical installations for left or right side exhausting Typical installations for bottom exhausting straight back offset Important Observe all governing codes and ordinances It is recommended that you exhaust your dryer to the outside for best performance Moisture and lint indoors may cause ...

Страница 4: ...d terminal block cover Power supply cord Direct wire This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of connection use Four wire connection instructions rear panel strain relief screws strain relief clamp sections terminal block cover hold down screw external ground condu...

Страница 5: ...cover into slot of dryer rear panel Secure cover with hold down screw 5 Connect the neutral wire white or center of power supply cord to the center silver colored terminal screw of the terminal block Tighten screw POWER SUPPLY CORD Three wire connection NEUTRAL NEUTRAL white or center 3 4 U L listed strain relief This blade connected to this conductor ring terminals spade terminals with upturned e...

Страница 6: ... clamp 4 Move dryer into final position Do not crush or kink exhaust vent Make sure dryer is level 3 Read the Use and Care Guide to fully understand your new dryer Select a full heat cycle not the air cycle and start dryer After five minutes open dryer door You should feel heat inside dryer If dryer does not operate properly check the following electrical supply is connected house fuse is intact a...

Страница 7: ... word DANGER or WARNING These words mean All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed You will be killed or seriously injured if you don t follow instructions You can be killed or seriously injured if you don t follow instructions Tools needed Check that you have everything necessary for c...