background image

Recessed area/closet installation

The dryer
door
extends
14" from
the front
of the
dryer
when fully
opened. 

Dryer location 

and dimensions

The location must provide:

Protection from weather and water: 

Do not

store or use dryer where it will be exposed to
water and weather.

Room temperature above 45°F: 

If room

temperature is below 45°F, automatic cycles may
not shut off.

3"

3"

48

sq. in.

**

24 sq. in.

**

0"

***

14"

max.

front view

1"

closet

door

** 

Minimum top and bottom air openings for closet door.

*** 

External exhaust elbow requires additional space.

Recessed area installation

0"

*

0"

*

front view

15"

Closet/confined area installation

If a closet door is installed: 

The minimum

unobstructed air openings are required. Louvered
doors with equivalent air openings are acceptable.

*

Wall, door and floor molding may require 

additional spacing.

terminal block cover

power supply
cord/cable 
strain relief

side view

For proper drying performance:

It is your responsibility to:

Panel A

Recessed
Closet

Back
5"/0"
5"/0"

Sides
1"/0" 
1"/0"

Top

18"/15" 
18"/15"

Front

— 

1"/1"

WARNING — To reduce the risk of fire this appliance
MUST BE EXHAUSTED OUTDOORS

Installation clearances

Use recommended clearance for easier installation.

Recommended/Minimum

Explosion Hazard

Keep flammable materials and
vapors, such as gasoline, away from
dryer.
Place dryer at least 18 inches above
the floor for a garage installation.
Failure to do so can result in death,
explosion, or fire.

WARNING

Electrical

requirements

Recommended ground method

It is the personal responsibility and obligation of the
customer to contact a qualified electrician to assure
that the electrical installation is adequate and is in
conformance with the National Electrical Code,
ANSI/NFPA 70 — latest edition

****

and all local

codes and ordinances.

Copies of the standards listed above may be obtained
from:

****

National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269

• A clothes dryer produces combustible lint and

must be exhausted outdoors.

• If codes permit, dryer may be installed in a

recessed area or closet using dimensions shown. 

• Dimensions are in inches and are the minimum

allowable.

• Additional spacing should be considered for ease

of installation and servicing. Companion
appliance spacing should also be considered.

Observe all governing codes and ordinances.

Check code requirements: 

Some codes limit or

do not permit installation of clothes dryers in
garages, closets, mobile homes or sleeping
quarters. Contact your local building inspector.

Important: Observe all governing codes and
ordinances.

A four-wire or three-wire, single phase, 120/240-
volt, 60-Hz, AC-only, electrical supply (or four-wire
or three-wire, 120/208-volt if specified on
model/serial rating plate) is required on a separate
30-ampere circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. 

If codes permit and a separate ground wire is 
used, it is recommended that a qualified electrician
determine that the ground path is adequate.

Comply with the installation specifications and
dimensions.

Consider spacing requirements for companion
appliances.

Make sure you have everything necessary for proper
installation.

Properly install dryer.

Contact a qualified installer to insure that the
electrical installation meets all national and local
codes and ordinances.

43-1/8"

11"

38-1/4"

Level floor: 

Maximum slope under entire dryer

should not be more than 1 inch. (If slope is greater
than 1 inch, install Extended Dryer Feet Kit, Part
No. 279810.) Clothes may not tumble properly and
automatic sensor cycles may not operate correctly if
dryer is not level.

Sturdy floor 

to support dryer weight of 

120 pounds.

27”

Dimensions shown with feet extended 1” from bottom of dryer.

14-1/8"

7-1/4"

left or right 
side exhaust 

bottom exhaust

back exhaust

4-1/4"

10-1/4"

14-1/8"

4"

Exhaust dimensions

14"

29-1/4"* (models with flush

mounted door handle)

30-1/4"* (models with

extended door handle)

*Most models will require at least 5" clearance behind the dryer for the dryer vent.

Содержание 3979171

Страница 1: ... Homeowner Keep Installation Instructions for future reference For best performance install dryer according to Installation Instructions Failure to complete installation as instructed could void warranty Save Installation Instructions for local electrical inspector s use U L listed strain relief 3 wire power supply cord with ring or spade terminals and U L listed strain relief 3 wire receptacle 10...

Страница 2: ...9 A clothes dryer produces combustible lint and must be exhausted outdoors If codes permit dryer may be installed in a recessed area or closet using dimensions shown Dimensions are in inches and are the minimum allowable Additional spacing should be considered for ease of installation and servicing Companion appliance spacing should also be considered Observe all governing codes and ordinances Che...

Страница 3: ...Do not use a plastic vent Do not use a metal foil vent Failure to do so can result in death or fire WARNING Typical installations for left or right side exhausting Typical installations for bottom exhausting straight back offset Important Observe all governing codes and ordinances It is recommended that you exhaust your dryer to the outside for best performance Moisture and lint indoors may cause ...

Страница 4: ...d terminal block cover Power supply cord Direct wire This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of connection use Four wire connection instructions rear panel strain relief screws strain relief clamp sections terminal block cover hold down screw external ground condu...

Страница 5: ...cover into slot of dryer rear panel Secure cover with hold down screw 5 Connect the neutral wire white or center of power supply cord to the center silver colored terminal screw of the terminal block Tighten screw POWER SUPPLY CORD Three wire connection NEUTRAL NEUTRAL white or center 3 4 U L listed strain relief This blade connected to this conductor ring terminals spade terminals with upturned e...

Страница 6: ... clamp 4 Move dryer into final position Do not crush or kink exhaust vent Make sure dryer is level 3 Read the Use and Care Guide to fully understand your new dryer Select a full heat cycle not the air cycle and start dryer After five minutes open dryer door You should feel heat inside dryer If dryer does not operate properly check the following electrical supply is connected house fuse is intact a...

Страница 7: ... word DANGER or WARNING These words mean All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed You will be killed or seriously injured if you don t follow instructions You can be killed or seriously injured if you don t follow instructions Tools needed Check that you have everything necessary for c...

Отзывы: