background image

Have questions about your dryer?

Check your Use and Care Guide for a toll-free number to call, or call your 
dealer. The dealer is listed in the Yellow Pages of your phone directory
under “Appliances — Household — Major — Service and Repair.”
When you call, you will need the dryer model number and serial number.
Both numbers are on the model/serial rating plate located in the door well
behind the dryer door and on front of opening.

Record the numbers here for handy reference:

Model No. 

Serial No.

Moving dryer to a new location?

Check with a licensed electrician to confirm that supply voltage at new home matches
voltage specified on the model/serial rating plate.

Shut off electrical
supply to dryer.
Unplug power supply
cord and tape it
securely to dryer. 
(Or disconnect power
supply cable from
dryer.)

Tape top 
to cabinet.

Tape door to
front panel.

Turn leveling
legs all the
way in.

Slide dryer onto cardboard or hardboard
before moving it across the floor to
prevent damaging floor covering.

Installation Instructions

Electric Dryer

Part No. 3979171

IMPORTANT:
Read and save these instructions.

Installer:  

Leave Installation Instructions with homeowner.

Homeowner:  

Keep Installation Instructions for future reference.

For best performance, 

install dryer according to 

Installation Instructions. Failure to complete installation 
as instructed could void warranty.

Save 

Installation Instructions for local electrical inspector’s use.

Before you start:

Electrical

If using a power supply cord:

Dryer power supply cord must be:

Check local codes and see electrical and venting
requirements, Panels A and B, before purchasing parts.
Determine if you will need to purchase a power 
supply cord kit or power supply cable.

If your outlet 

looks like this:

Choose this 

power supply cord:

4-wire receptacle 

(14-30R)

4-wire power supply cord with 

ring or spade terminals and 

U.L.-listed strain relief

3-wire power supply cord with 

ring or spade terminals and 

U.L.-listed strain relief

3-wire receptacle 

(10-30R)

If connecting by direct wire:

Power supply cable must match power supply 
(4-wire or 3-wire) and be:
• flexible armored or non-metallic sheathed copper

cable (with ground wire). All current-carrying wires
must be insulated. See Panels D and E. 

• 10-GAUGE SOLID COPPER WIRE. (Do not use

aluminum.)

• at least 4 feet long.

Printed in U.S.A.

Part No. 3979171

© 2001 Whirlpool Corporation 

Benton Harbor, Michigan 49022 

Your safety and the safety of others 

is very important.

We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.

This is the safety alert symbol. This
symbol alerts you to hazards that can kill
or hurt you and others. All safety

messages will be preceded by the safety alert symbol
and the word “DANGER” or “WARNING”. These
words mean:

All safety messages will identify the hazard, tell
you how to reduce the chance of injury, and tell you
what can happen if the instructions are not
followed.

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

Tools needed:

Check that you have everything necessary for correct
installation. Proper installation is your responsibility.

Parts supplied:

4 leveling legs

Remove parts package from
dryer drum. Check that all 4
legs were included.

• U.L.-listed
• 120/240-volt 

minimum

• 30-ampere
• Type SRD or SRDT
• At least 4 feet long

The wires that connect to the dryer must end in ring
terminals or spade terminals with upturned ends.
The receptacle must be located within 3 feet of the
top, back center of the control console.

Parts needed:

Venting

Exhaust hood 

Do Not use exhaust hoods with magnetic latches.

Preferred                    Acceptable

4"

4"

2-1/2"

Mobile home installations require:

• Mobile Home Installation Kit, Part Number 346764*
• Metal exhaust system hardware*

Floors sloped greater than 1 inch:

Require Extended Dryer Feet Kit, Part No. 279810*
*

Available for purchase from your dealer.

DANGER

WARNING

•  #2 Phillips screwdriver
•  flat-blade screwdriver
•  adjustable wrench that

opens to 1" or 1" hex-
head socket wrench (for
adjusting dryer feet)

•  level
•  wire stripper (direct wire

installations)

•  safety glasses
•  caulking gun and

compound (new vent
installation)

•  gloves
•  tin snips (new vent

installations)

Four-inch heavy metal exhaust vent and clamps
must be used. Dura Safe™ vent products are
recommended.
Dura Safe vent products can be purchased from your
dealer or by calling Whirlpool Parts & Accessories 
1-800-442-9991, Mon-Fri: 8am to 9pm (CST), Sat:
9am to 4:30pm (CST). Visit our internet site at 
http://www.whirlpoolappliances.com/accessories
See Panel C for more information.

Fire Hazard

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can
result in death or fire.

WARNING

Содержание 3979171

Страница 1: ... Homeowner Keep Installation Instructions for future reference For best performance install dryer according to Installation Instructions Failure to complete installation as instructed could void warranty Save Installation Instructions for local electrical inspector s use U L listed strain relief 3 wire power supply cord with ring or spade terminals and U L listed strain relief 3 wire receptacle 10...

Страница 2: ...9 A clothes dryer produces combustible lint and must be exhausted outdoors If codes permit dryer may be installed in a recessed area or closet using dimensions shown Dimensions are in inches and are the minimum allowable Additional spacing should be considered for ease of installation and servicing Companion appliance spacing should also be considered Observe all governing codes and ordinances Che...

Страница 3: ...Do not use a plastic vent Do not use a metal foil vent Failure to do so can result in death or fire WARNING Typical installations for left or right side exhausting Typical installations for bottom exhausting straight back offset Important Observe all governing codes and ordinances It is recommended that you exhaust your dryer to the outside for best performance Moisture and lint indoors may cause ...

Страница 4: ...d terminal block cover Power supply cord Direct wire This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of connection use Four wire connection instructions rear panel strain relief screws strain relief clamp sections terminal block cover hold down screw external ground condu...

Страница 5: ...cover into slot of dryer rear panel Secure cover with hold down screw 5 Connect the neutral wire white or center of power supply cord to the center silver colored terminal screw of the terminal block Tighten screw POWER SUPPLY CORD Three wire connection NEUTRAL NEUTRAL white or center 3 4 U L listed strain relief This blade connected to this conductor ring terminals spade terminals with upturned e...

Страница 6: ... clamp 4 Move dryer into final position Do not crush or kink exhaust vent Make sure dryer is level 3 Read the Use and Care Guide to fully understand your new dryer Select a full heat cycle not the air cycle and start dryer After five minutes open dryer door You should feel heat inside dryer If dryer does not operate properly check the following electrical supply is connected house fuse is intact a...

Страница 7: ... word DANGER or WARNING These words mean All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed You will be killed or seriously injured if you don t follow instructions You can be killed or seriously injured if you don t follow instructions Tools needed Check that you have everything necessary for c...