D.
Level dryer
Dryer must be level to reduce noise and
assure proper performance.
Slide dryer onto cardboard or hardboard
before moving across floor to prevent floor
damage.
1.
Move dryer close to its permanent
location. Leave enough room to connect
exhaust vent. Remove cardboard or hardboard
from under dryer.
2.
Check levelness of dryer by placing a
level on top of dryer, first side to side, then
front to back. If dryer is not level, adjust dryer
legs up or down.
If legs are not long enough to level dryer,
order Extended Dryer Feet Kit, Part No.
279810 (sold two legs per kit), from your
dealer.
1.
Using a 4" clamp, connect exhaust
vent to exhaust outlet in dryer. If connecting
to existing exhaust vent, make sure the vent
is clean. The dryer exhaust vent
must
fit over
the dryer exhaust outlet and inside the
exhaust hood.
Make sure exhaust vent is secured to exhaust
hood with a 4" clamp.
Panel F
E.
Make gas
connection
1.
Remove the
red cap from the
gas pipe. (You may
need to use pliers.)
Move the dryer
into its final
position.
2.
Connect gas supply to dryer. Use pipe-
joint compound resistant to the action of L.P.
gas for gas connections. If flexible metal tubing
is used, be certain there are no kinks.
3.
Turn the shutoff valve in the gas supply
line to the “open” position.
F.
Exhaust dryer
4.
Use a brush and liquid detergent to
test all external gas connections for leaks.
Bubbles around connections will indicate a
leak. If a leak appears, shut off gas valve
controls and tighten connections. Then check
connections again.
2.
Move dryer into final position. Do not
crush or kink exhaust vent. Make sure dryer is
level.
3.
Read the Use and Care Guide to fully
understand your new dryer. Select a full heat
cycle (not the air cycle) and start dryer. After
five minutes, open dryer door. You should feel
heat inside dryer.
If the burner did not ignite and you do not
feel heat inside the dryer, shut the dryer off for
5 minutes. Then check that:
✔
controls are set in a running or “On”
position.
✔
start button has been pushed firmly.
✔
gas supply line shutoff valve is open.
Repeat 5-minute test. If dryer still does not
operate properly, check the following:
✔
electrical supply is connected.
✔
house fuse is intact and tight; or circuit
breaker has not tripped.
✔
dryer door is closed.
If dryer makes an unusual noise, check that
dryer is level.
G.
Check operation
1.
Check that you:
✔
did not skip any steps.
✔
installed all parts.
✔
properly installed dryer legs.
✔
leveled dryer.
✔
have all the tools you started with.
2.
Plug power supply cord into grounded
3-prong outlet.
4" clamp
4" clamp
to dryer
manual
shutoff valve
“open” position
rigid gas supply line