Whirlpool 3978906 Скачать руководство пользователя страница 4

Important: Observe all governing codes and
ordinances.

Dryer MUST BE EXHAUSTED to the outside.

Moisture and lint indoors may cause:
• lint to gather around the dryer where it can be

fuel for a fire.

• moisture damage to woodwork, furniture,

paint, wallpaper, carpet, etc.

• housecleaning problems and health problems.

Dura Safe

TM

venting products are

recommended and are available from your
dealer.
Four-inch diameter vent is required.
Use a heavy metal vent. 

Do Not use plastic or

metal foil vent.

Rigid metal vent is recommended 

to prevent

crushing and kinking.

Flexible metal vent

must be fully extended and

supported when the dryer is in
its final position. Remove excess
flexible vent to avoid sagging
and kinking that may result in
reduced air flow.

An exhaust hood 

should cap

the exhaust vent to prevent
rodents and insects from
entering the home.

Exhaust outlet hood 

must be

at least 12 inches from the ground or any object
that may be in the path of the exhaust (such as
flowers, rocks or bushes, etc.).

If using an existing exhaust system, clean lint
from entire length of system and make sure
exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid
metal or flexible metal vent.

Use clamps 

to seal all joints. Do Not use duct

tape, screws or other fastening devices that
extend into the interior of the vent to secure
vent.

Service check: 

Back pressure in any exhaust

system used must not exceed 0.6 inches in
water column measured with an incline
manometer at the point that exhaust vent
connects to dryer.

The exhaust
outlet 

is located

at the center of
the rear of the
dryer.

better 

exhaust air flow

acceptable 

Determine vent length

The maximum length 

of the exhaust system

depends upon:

• the type of vent (rigid or flexible metal).
• the number of elbows used.

1. See the exhaust vent length chart that

matches your type hood for the maximum
vent lengths you can use. 

Do not use vent runs longer than
specified in exhaust vent length charts.

Exhaust systems longer than specified will:
— accumulate lint creating a potential fire 

hazard.

— shorten the life of the dryer.
— reduce performance, resulting in longer 

drying times and increased energy usage.

2. Determine the number of elbows you will

need.

3. In the column listing the type of metal vent

you are using (rigid or flexible), find the
maximum length of metal vent on the same
line as the number of elbows.

Plan the exhaust vent installation

The exhaust vent 

can be

routed up, down, left,
right or straight out the
back of the dryer. See
“Recessed area/closet
installation” section,
Panel A, for general
space requirements.

Select the route that will provide the
straightest and most direct path outdoors.

Plan the installation to use the fewest number of
elbows and turns. 

When using elbows or making turns, 

allow as

much room as possible. Bend vent gradually to
avoid kinking. 

Route the vent

Panel C

The maximum length using a 2" x 6" rectangular
vent with 2 elbows and a 2-1/2" exhaust hood is 
8 feet.

For exhaust systems not covered by
exhaust vent length charts 

(such as multiple

unit hookups, plenums, and power-assist
fans), see Service Manual, Part No. 603197.
(To purchase the Service Manual, see your Use
and Care Guide for a toll-free telephone
number.)

Number of 

Rigid 

Flexible

90° elbows (fully 

extended)

0

58 ft.

28 ft.

1

48 ft.

23 ft.

2

38 ft.

19 ft.

3

29 ft.

17 ft.

4

21 ft.

15 ft.

Maximum length of

4" diameter metal vent

When you have a 2-1/2" hood …

2-1/2"

Acceptable —

Number of 

Rigid 

Flexible

90° elbows (fully 

extended)

0

64 ft.

36 ft.

1

54 ft.

31 ft.

2

44 ft.

27 ft.

3

35 ft.

25 ft.

4

27 ft.

23 ft.

Maximum length of

4" diameter metal vent

When you have a 4" hood …

4"

4"

Preferred —

Exhaust

requirements

skirting

enclosed area

outside
wall

floor

Mobile home installation
requirements

If codes permit, this appliance is suitable for
mobile home installations. The installation of
the dryer must conform to Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Homes Construction and
Safety, Title 24, HUD Part 280) or latest
edition.

The dryer must be fastened to the floor.

Order Mobile Home Installation Kit, Part No.
346764, from your dealer. Kit includes the
necessary fastening hardware and detailed
installation instructions. Metal exhaust system
is also available through your dealer.

The dryer must be exhausted outside.

12" min.

exhaust

outlet

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to do so can result in death or
fire.

WARNING

•  Do Not use non-metal flexible vent or

exhaust hoods with magnetic latches.

•  Metal exhaust vent must be four inches 

in diameter.

•  Do Not exhaust dryer into any gas vent,

chimney, furnace, cold air vent, wall, ceiling
concealed space of a building, attic or crawl
space, or any other vent used for venting.

•  Do Not install flexible vent in enclosed

walls, ceilings or floors.

The exhaust vent must be securely fastened to
a non-combustible portion of the mobile
home structure. The exhaust system must not
terminate beneath the mobile home.

Содержание 3978906

Страница 1: ...ter than 1 inch Require Extended Dryer Feet Kit Part No 279810 Available for purchase from your dealer 4 4 2 1 2 Benton Harbor Michigan 49022 Gas Dryer Set to operate on NATURAL GAS Part No 3978906 GAS DRYER Shut off electrical supply to dryer Unplug power supply cord and tape it securely to dryer Shut off gas supply valve in the gas supply line Disconnect gas fittings from dryer and cap gas suppl...

Страница 2: ...e considered 3 3 48 sq in 24 sq in 4 14 max front view 1 closet door Minimum top and bottom air openings for closet door External exhaust elbow requires additional space Recessed area installation 0 0 front view 18 Closet confined area installation If a closet door is installed The minimum unobstructed air openings are required Louvered doors with equivalent air openings are acceptable Wall door a...

Страница 3: ...in 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 latest edition Pipe joint compounds resistant to the action of L P gas must be used Gas requirements Check that dryer is equipped with the correct burner for the particular type of gas in the home Burner information will be found on the model serial rating plate in door well of the dryer If this information does not a...

Страница 4: ...ion The exhaust vent can be routed up down left right or straight out the back of the dryer See Recessed area closet installation section Panel A for general space requirements Select the route that will provide the straightest and most direct path outdoors Plan the installation to use the fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent ...

Страница 5: ... on its back on the cardboard corners diamond marking 3 Start to screw legs into holes by hand Use an adjustable wrench or 1 hex head socket wrench to finish turning legs until you reach the ridge with the diamond marking 4 Stand dryer up on cardboard or hardboard Now start installation If installing washer and dryer install dryer first SLIDE DRYER ONTO CARDBOARD OR HARDBOARD BEFORE MOVING ACROSS ...

Страница 6: ...il strike snaps into catch 6 Remove door strike D from cabinet Remove door strike plug E Insert door strike in new hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 7 Slowly close door and check that door strike aligns with door catch F If door does not close completely slide door catch left or right within slot until strike snaps into catch Avai...

Страница 7: ...n the shutoff valve in the gas supply line to the open position F Exhaust dryer 4 Use a brush and liquid detergent to test all external gas connections for leaks Bubbles around connections will indicate a leak If a leak appears shut off gas valve controls and tighten connections Then check connections again 2 Move dryer into final position Do not crush or kink exhaust vent Make sure dryer is level...

Страница 8: ...vel collar wall connection Provides 2 1 2 clearance between dryer and wall Great for closet installations 0 18 18 29 or 29 50 periscopes include one male snap lock fitting one extra long draw band collar and one clamp 21 2 2 1 2 Periscopes For Offset Outlets Tight Installations Use when vent outlets overlap or are offset Excess length can be trimmed to fit 18 29 and 29 50 Periscope 0 18 Periscope ...

Страница 9: ...manual and on your appliance Always read and obey all safety messages WARNING DANGER This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will be preceded by the safety alert symbol and the word DANGER or WARNING These words mean All safety messages will tell you what the potential hazard is tell you how to reduce the ...

Отзывы: