Panel C

Exhaust requirements

POWER SUPPLY CORD

OR DIRECT WIRE

Where local codes DO NOT permit
connecting the cabinet-ground
conductor to the neutral (white)
wire:

Where local codes permit
connecting cabinet-ground
conductor to the neutral wire of the
power supply cable:

Where local codes permit
connecting cabinet-ground
conductor to the neutral wire:

Three-wire connection...

B.

POWER SUPPLY CORD

Figure 8

center silver-colored
terminal block screw and
neutral white wire

ground wire (green
with yellow stripes)

1. Disconnect the power supply.

2. Remove terminal block cover.
3. Install copper three-wire power supply

cord through strain relief.

4. Remove the ground wire (green with

yellow stripes) from under center, silver-
colored terminal block screw and
connect to external ground connector
(see Figure 8).

5. Connect the neutral wire (white or

center) of the power supply cord to the
center, silver-colored terminal screw of
the terminal block. Connect the other
wires to the outer terminals. Tighten
screws firmly.

6. Tighten strain relief screws.
7. Replace the terminal block cover.

external ground connector

DIRECT WIRE

1. Disconnect the power supply.

2. Remove terminal block cover.
3. Strip 3-1/2 inches of outer covering from

end of cable. If using three-wire cable
with I wire, cut the bare wire even with
outer covering.  Strip 1 inch of insulation
from the end of each insulated wire (see
Figure 9). 

Important: Observe all governing codes
and ordinances.

It is recommended that you exhaust
your dryer to the outside for best
performance. 

Moisture and lint indoors

may cause:
• Lint to gather around the dryer where

it can be fuel for a fire.

• Moisture damage to woodwork,

furniture, paint, wallpaper, carpet,
etc.

• Housecleaning problems and health

problems.

If the washer/dryer is installed in a
confined area such as a bedroom,
bathroom or closet, it must be
exhausted to the outside

and provision

must be made for enough air for
ventilation. Check governing codes and
ordinances. Also refer to the “Recessed
and closet installation instructions” on
Panel G.

Dura Safe

TM

vent products are

recommended and are available from
your dealer. See Panel G.
Four-inch diameter vent is required.
Use a heavy metal vent. 

Do not use plastic or

metal foil vent.
•  Do Not use non-metal flexible vent, or

exhaust hoods with magnetic latches.

•  Do Not exhaust dryer into a chimney,

furnace, cold air vent, attic or crawl space,
or any other vent used for venting.

•  Do Not install flexible vent in enclosed walls,

ceilings or floors.

Rigid metal vent is recommended

to prevent

crushing and kinking.

Flexible metal vent 

must be fully extended

and supported when the dryer is in its final
position.
Remove excess flexible vent to avoid
sagging and kinking that may result in
reduced air flow.

An exhaust hood

should cap the exhaust

vent to prevent rodents and insects from
entering the home.

Exhaust outlet hood

must be at least 12

inches from the ground or
any object that may be in
the path of the exhaust
(such as flowers, rocks or
bushes, etc.).

If using an existing exhaust
system, clean lint from entire
length of system and make sure exhaust
hood is not plugged with lint.

Replace any plastic or metal foil vent with
rigid metal or flexible metal vent.

Use clamps 

to seal all joints. Do not use duct

tape, screws or other fastening devices that
extend into the interior of the vent to secure
vent.

Service check:

Back pressure in any exhaust

system used must not exceed 0.6 inches in
water column measured with an incline
manometer at the point that exhaust vent
connects to dryer.

Direct wire preparation

Figure 9

10-gauge, 3-wire or, 
10-gauge, 3-wire with
ground wire (Romex)

3/4" U.L.-listed
strain relief 

Bare wire cut short. Wire is not
used. Dryer is grounded through
direct wire cable.

to disconnect
box 

red

white

black

NEUTRAL

1"

3-1/2"

wires stripped 
of insulation

Figure 10

Shape the end of each
wire into a “U” shaped
hook (see Figure 10). 

u-shaped
hook

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to do so can result in death or
fire.

Three-wire connection...

ground wire (green with
yellow stripes)

center silver-colored
terminal block screw and
neutral white wire

external ground connector

Figure 11

4. Install copper, three-wire power supply

cable through strain relief.

5. Remove the ground wire (green with

yellow stripes) from under center, silver-
colored terminal block screw and
connect to external ground connector
(see Figure 11).

6. Slide the hook end of the neutral (white

or center) wire from the three-wire
power supply cable under the center,
silver-colored  terminal screw of the
terminal block. Squeeze the hook end of
the wire together. Tighten screw.

7. Connect the other wires to the 

outer terminals using the same method.
Tighten screws firmly (see Figure 11).

8. Tighten strain relief screws.
9. Replace the terminal block cover.

WARNING

Fire Hazard

Use a new UL approved 30 ampere
power supply cord.

Use a UL approved strain relief.

Disconnect power before making
electrical connections.

Connect neutral wire (white or center
wire) to center terminal (silver).

Ground wire (green or bare wire) must
be connected to green ground
connector.

Connect remaining 2 supply wires to
remaining 2 terminals (gold).

Securely tighten all electrical
connections.

Failure to do so can result in death,
fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL approved strain relief.

Disconnect power before making
electrical connections.

Connect neutral wire (white or center
wire) to center terminal (silver).

Ground wire (green or bare wire) must
be connected to green ground
connector.

Connect remaining 2 supply wires to
remaining 2 terminals (gold).

Securely tighten all electrical
connections.

Failure to do so can result in death,
fire, or electrical shock.

12" min.

Connect separate copper ground wire 
from external ground connector 
to approved ground.

separate copper
ground wire

external
ground
connector

ground wire (green
with yellow stripes)

Figure 12

center silver-colored
terminal block screw and
neutral white wire

1. Disconnect the power supply.

2. Remove terminal block cover.
3. Install solid copper, power supply cord or

cable through strain relief.

4. Remove the ground wire (green with

yellow stripes) from the external ground
connector.

5. Connect the ground wire (green with

yellow stripes) and the neutral (white)
wire of the power supply cord or direct
wire cable to the center, silver-colored
terminal screw of the terminal block.
Connect the other wires to the outer
terminals. Tighten screws (see Figure 12). 

6. Connect a separate copper ground wire

(No.-10 minimum) from the external
ground screw to an adequate ground.

7. Tighten strain relief screws. 
8. Replace the terminal block cover.

Содержание 3397616

Страница 1: ...4 Controls are set in a running or ON position If you need assistance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer dryer mo...

Страница 2: ...ified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Untape and open washer lid Remove packages and hoses from washer Drain hose may also be installed to a laundry tub or floor drain system See Panel F level Phillips screwdriver pliers utility knife safety glasses...

Страница 3: ... wire connection A DIRECT WIRE 1 Disconnect the power supply 2 Remove terminal block cover 3 Strip 5 inches of outer covering from end of cable Leave bare ground wire at 5 inches Cut 1 1 2 inches from 3 remaining insulated wires Strip insulation back 1 inch see Figure 6 3 4 U L listed strain relief red white black to disconnect box NEUTRAL 10 gauge 3 wire with ground wire Romex Direct wire prepara...

Страница 4: ...tape screws or other fastening devices that extend into the interior of the vent to secure vent Service check Back pressure in any exhaust system used must not exceed 0 6 inches in water column measured with an incline manometer at the point that exhaust vent connects to dryer Direct wire preparation Figure 9 10 gauge 3 wire or 10 gauge 3 wire with ground wire Romex 3 4 U L listed strain relief Ba...

Страница 5: ... of the drain hose 3 While holding clamp open work end of drain hose onto drain connector 4 Position clamp over the drain hose area marked clamp Release clamp Clamp should be 1 4 inch from end of drain hose Save the shipping strap for use in Step 18 Pull the shipping strap completely out of the washer drain hose connector clamp drain hose 1 4 1 4 max cotter pins drain hose clamp yellow clamp Panel...

Страница 6: ...t marker 14 Attach bottom inlet hose inlet marked H to hot water faucet Attach top inlet hose inlet marked C to cold water faucet Tighten couplings to the faucets by hand Use pliers to make final two thirds turn Move washer dryer to its permanent location Remove cardboard hardboard from under washer dryer 15 Carefully move the washer dryer into final position Tilt washer dryer forward raising back...

Страница 7: ... B C strap strap 19 Put hook end of drain hose in laundry tub or standpipe Tightly wrap the shipping strap around the drain hose and laundry tub or standpipe as shown in Figures A and B Push plug into the nearest hole in the shipping strap If the water inlet faucets and drain standpipe are recessed put hook end of drain hose in standpipe Tightly wrap the shipping strap around the drain hose and fa...

Страница 8: ... 1 2 recess width 5 recess depth 27 cold water inlet exhaust outlet 36 3 4 28 1 2 drain outlet 22 3 4 0 WARNING To reduce the risk of fire this appliance MUST BE EXHAUSTED OUTDOORS Most installation will require at least 5 inch clearance behind the dryer for the dryer vent Location must be large enough to fully open dryer door SURE CONNECTTM Vent Kit CRUSH RESISTANT Dura SafeTM Kits Make Installat...

Страница 9: ...ance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer dryer model number and serial number Both numbers can be found on the mod...

Отзывы: